• Title/Summary/Keyword: Industrial Control System

Search Result 4,159, Processing Time 0.038 seconds

LED Line Lamp System for Intelligent Road (지능형 도로 LED 라인조명 시스템)

  • Yang, Jin-Young;Kim, Won-Sik;Kim, Jin-Hee;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.133-137
    • /
    • 2009
  • This paper presents the development of smart road line lamp system consisting light control device. It can perform the individual power control or partial on/off control of a LED lamp by control center and can detect the error of the LEDs by current sensing. Also, the ability to control the brightness and period of on/off by detecting the car's existence. This light control circuit consists of road line lamp unit device. It can give a lot of solutions when the server, which controls the whole system, is operated through CDMA(Code-Division Multiple Access) network.

  • PDF

A Study about XML Application for Integrating Field Device (필드기기 통합구성을 위한 XML 적용에 관한 연구)

  • Moon, Yong-Seon;Lee, Myung-Bok;Jeong, Cheol-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.8
    • /
    • pp.733-739
    • /
    • 2005
  • Device Description that is described as C-based DDL(Device Description Language) should be provided for the control system to use the progressive function of field device in the distributed control system. DD expresses field device function itself and parameter. DD is used to set a necessary function far a control strategy in the central control system. DD technology which was adopted as international standard IEC 61804-Part 2 is being used in PROFIBUS, Foundation Fieldbus and HART. However, the DD is dependent to the fieldbus and it doesn't have a suitable form in the industrial Ethernet. This paper presents the possibility of a change from EDD(Electronic Device Description) and GSD(General Slave Data) used for integrating field devices to XDD(XML for Device Description) and verifies it's effectiveness. Also, this paper presents research assignment on the XML application in the distributional system from now on by examining the possibility of Ethernet`s development in the industrial area.

Development of control algorithm for TTX Tilting Train eXpress propulsion system (틸팅 차량용 추진제어장치의 제어 알고리즘 개발)

  • Kim, Hyung-Cheol;Lee, Eun-Kyu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1343-1345
    • /
    • 2005
  • In this paper, control schemes are proposed for a propulsion system(Converter/Inverter) of the TTX(Tilting Train express). In developed traction converter, unity power factor control, compensation method of dc link voltage have been applied. Output current of converter contains harmonics ripple at twice input ac line frequency, which causes a ripple in the dc link voltage so that control scheme is developed in inverter system to reduce the pulsating torque current. At low speed region, vector control scheme is applied and slip frequency control is adopted at high speed region. The performance of propulsion system will be verified by simulation and prototype experimental results.

  • PDF

Design of Robust $\bar{x}$ Control Chart Using a Location Parameter (위치모수를 이용한 로버스트 $\bar{x}$ 관리도의 설계)

  • Chung, Young-Bae;Kim, Yon-Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.1
    • /
    • pp.151-156
    • /
    • 2014
  • Control charts are generally used for process control, but the role of traditional control charts have been limited in case of a contaminated process. Traditional $\bar{x}$ control charts have not been activated well for such a problem because of trying to control processes as center line and control limits changed by the contaminated value. This paper is to propose robust $\bar{x}$ control charts which is considering a location parameter in order to respond to contaminated process. In this paper, we consider $\bar{x}_{\alpha}$, that is trimmed rate; typically ten percent rate is used. By comparing with p, ARL value, the responding results are decided. The comparison resultant results of proposed two control charts are shown and are well contrasted.

Development of Integrated Variable Sampling Interval EngineeringProcess Control & Statistical Process Control System (가변 샘플링간격 EPC/SPC 결합시스템의 개발)

  • Lee, Sung-Jae;Seo, Sun-Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.32 no.3
    • /
    • pp.210-218
    • /
    • 2006
  • Traditional statistical process control (SPC) applied to discrete part industry in the form of control charts can look for and eliminate assignable causes by process monitoring. On the other hand, engineering process control (EPC) applied to the process industry in the form of feedback control can maintain the process output on the target by continual adjustment of input variable. This study presents controlling and monitoring rules adopted by variable sampling interval (VSI) to change sampling intervals in a predetermined fashion on the predicted process levels under integrated EPC and SPC systems. Twelve rules classified by EPC schemes(MMSE, constrained PI, bounded or deadband adjustment policy) and type of sampling interval combined with EWMA chart of SPC are proposed under IMA (1,1) disturbance model and zero-order (responsive) dynamic system. Properties of twelve control rules under three patterns of process change (sudden shift, drift and random shift) are evaluated and discussed through simulation and control rules for integrated VSI EPC and SPC systems are recommended.

Analysis of a Queueing Model with Time Phased Arrivals

  • Kim, Che-Soong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.4
    • /
    • pp.107-118
    • /
    • 2007
  • A single-server queueing model with infinite buffer and batch arrival of customers is considered. In contrast to the standard batch arrival when a whole batch arrives into the system at one epoch, we assume that the customers of an accepted batch arrive one-by one in exponentially distributed times. Service time is exponentially distributed. Flow of batches is the stationary Poisson arrival process. Batch size distribution is geometric. The number of batches, which can be admitted into the system simultaneously, is subject of control. Analysis of the joint distribution of the number batches and customers in the system and sojourn time distribution is implemented by means of the matrix technique and method of catastrophes. Effect of control on the main performance measures of the system is demonstrated numerically.

  • PDF

Robust Predictive Feedback Control for Constrained Systems

  • Giovanini, Leonardo;Grimble, Michael
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.4
    • /
    • pp.407-422
    • /
    • 2004
  • A new method for the design of predictive controllers for SISO systems is presented. The proposed technique allows uncertainties and constraints to be concluded in the design of the control law. The goal is to design, at each sample instant, a predictive feedback control law that minimizes a performance measure and guarantees of constraints are satisfied for a set of models that describes the system to be controlled. The predictive controller consists of a finite horizon parametric-optimization problem with an additional constraint over the manipulated variable behavior. This is an end-constraint based approach that ensures the exponential stability of the closed-loop system. The inclusion of this additional constraint, in the on-line optimization algorithm, enables robust stability properties to be demonstrated for the closed-loop system. This is the case even though constraints and disturbances are present. Finally, simulation results are presented using a nonlinear continuous stirred tank reactor model.

Real-Time Fault Detection in Discrete Manufacturing Systems Via LSTM Model based on PLC Digital Control Signals (PLC 디지털 제어 신호를 통한 LSTM기반의 이산 생산 공정의 실시간 고장 상태 감지)

  • Song, Yong-Uk;Baek, Sujeong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.2
    • /
    • pp.115-123
    • /
    • 2021
  • A lot of sensor and control signals is generated by an industrial controller and related internet-of-things in discrete manufacturing system. The acquired signals are such records indicating whether several process operations have been correctly conducted or not in the system, therefore they are usually composed of binary numbers. For example, once a certain sensor turns on, the corresponding value is changed from 0 to 1, and it means the process is finished the previous operation and ready to conduct next operation. If an actuator starts to move, the corresponding value is changed from 0 to 1 and it indicates the corresponding operation is been conducting. Because traditional fault detection approaches are generally conducted with analog sensor signals and the signals show stationary during normal operation states, it is not simple to identify whether the manufacturing process works properly via conventional fault detection methods. However, digital control signals collected from a programmable logic controller continuously vary during normal process operation in order to show inherent sequence information which indicates the conducting operation tasks. Therefore, in this research, it is proposed to a recurrent neural network-based fault detection approach for considering sequential patterns in normal states of the manufacturing process. Using the constructed long short-term memory based fault detection, it is possible to predict the next control signals and detect faulty states by compared the predicted and real control signals in real-time. We validated and verified the proposed fault detection methods using digital control signals which are collected from a laser marking process, and the method provide good detection performance only using binary values.

The study on Intergrated SCADA system for Powerplant using Soft logic (SOFT LOGIC을 이용한 전력설비 통합제어 시스템구축에 관한 연구)

  • Cho, Nam-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2443-2445
    • /
    • 2000
  • In this paper, the Intergrated SCADA is used to computer systems designed to perform the following functions for power plant. - to collect data from industrial plant devices or transducers - to process and perform calculations on the collected data - to present collected and derived data on displays on MMI - to accept commands entered by human operators and act on them such as sending control commands to plant devices. This system is characterised by open architectured that is based on the internationally recognized industrial standard for industrial automation control language, the IEC 1131-3

  • PDF