• Title/Summary/Keyword: Induced voltages

Search Result 167, Processing Time 0.022 seconds

RFID Noise Reduction Using a Multi-Coil Antenna (다중 코일 안테나를 이용한 RFID 유도 잡음의 감소)

  • Lee, Seong-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.6
    • /
    • pp.603-611
    • /
    • 2008
  • In this paper, we introduce a multi-coil antenna which is useful for reducing the effects of radio frequency noise in an inductively coupled RFID system. A multi-coil antenna is composed of a central coil and four subsidiary coils that are connected in series. A multi-coil antenna is designed so that the total noise disappear when the induced voltages of a central coil and subsidiary coils are added. The noise in a multi-coil antenna was about 30 dB lower than that in a single coil antenna. The multi-coil antenna is very effective in noise reduction even in an environment that the spatial distribution of RF noise is changed abruptly, and the induced noise was about 16 dB lower than that in a dual coil antenna.

Inductive Micro Displacement Detecting System with High Sensitivity and Low Linearity Error

  • Park, Dong-June;Park, In-Mook;Kim, Soo-Hyun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.3
    • /
    • pp.54-60
    • /
    • 2001
  • A newly designed inductive micro displacement detecting system is presented. The proposed inductive system consists of driving coils, position-detecting coils, cores, and closed-loop formed magnetic blocks. The cores and magnetic blocks are made of Mn-Zn ferrite. When AC sine wave is applied to the driving coils, the time derivative flux is generated within the system, and then induced voltages arise in the position-detecting coils according to the core\`s position. Putting the cores to be moved proportionally to the input displacement, the induced voltage is proportional to input displacement. The parameters that affect the system characteristics are turn ratio, air-gap size, excitation frequency, overlap area, load resistance, capacitance effect, and so forth. Based on the experimental results, the system parameters are selected in such a way as to have high sensitivity ad stable responses. The sensitivity of the proposed inductive displacement-detecting system is greater than 2800mV.V-1mm-1 and the linearity error is below $\pm$0.10% in the range of $\pm$200㎛.

  • PDF

The Analysis and Experimental Investigation of the Diagnosis of Rotor Faults for the Squirrel Cage Induction Motor (농형유도전동기의 회전자 불량진단에 관한 해석 및 실험적 고찰)

  • Kim, Chang-Eob;Chung, Gyo-Bum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.27-34
    • /
    • 2007
  • The rotor faults of induction motors may cause bad effects on the performance of the induction motor. This paper proposes the detecting technique of these faults by analyzing the waveform of the induced current and voltage of search coil using numerical analysis and the experiment. Several defective rotor bars are simulated to analyze the fault conditions-broken bars and high resistance of rotor bars. In order to prove the usefulness of the proposed method, we made an prototype experimental apparatus. The waveform of the induced voltages in search coil has the obvious characteristics and it is easy to differentiate the normal rotor from the abnormal one. The experimental results show that the proposed method is useful to detect the rotor fault conditions.

A New Algorithm of B-waveform Control for the Measurement of Two-dimensional Magnetic Properties of Electrical Steel Sheets using Single Sheet Tester (SST를 이용한 전기강판의 2차원 자기특성 측정을 위한 새로운 자속밀도 파형 제어법)

  • Eum, Young-Hwan;Yoon, Hee-Sung;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1167-1174
    • /
    • 2008
  • The measurement of two-dimensional magnetic properties of electrical steel sheet using single sheet tester (SST) requires to control the B-waveform as sinusoidal. The SST electric circuit, in general, has inductance, and this makes the phase lag in electric current. For this reason, the induced voltages of H- or B-coil may have phase difference from the exciting voltage. In this paper, a new algorithm is developed to compensate the phase difference and makes the B-waveform control efficient. The developed algorithm experimentally calculates the phase difference based on the measured waveform of the induced voltage for the magnetic field intensity along transverse direction. By using the proposed algorithm, the two-dimensional magnetic properties of grain-orientated electrical steel sheet (30PG110) is measured up to 2T. By comparing the measured B- and H-waveforms, the effectiveness of the proposed algorithm is proven.

Sensorless Speed Control of Induction Motor with an Improved Rotor Flux Estimator (개선된 자속 추정기에 의한 유도 전동기의 센서리스 속도제어)

  • Kim, J.S.;Cho, S.Y.;Ham, H.C.;Park, G.O.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.260-262
    • /
    • 1998
  • A new method of induction motor drive, which requires not shaft encoder, is presented. This system has both torque and speed controls that are performed by vector control. The scheme is on the basis of a rotor flux speed control, which is performed by torque producing current and rotor flux, derived from the stator voltages and currents. But, there is a problem with respect to the calculated rotor flux vector, which is an integrating operation by which the rotor induced voltage is converted into the rotor flux. The calculated rotor flux does not work so that it is unstable in initial operation, as motor speed approaches zero. For the proposed rotor flux estimator, a lag circuit is employed, to which both the motor-induced voltage and rotor flux command are imposed, and it is possible to calculate even a low frequency down to standstill. We show the validity of the proposed control method through several computer simulations.

  • PDF

Electrofusion of Tobacco and Pea Protoplasts (전기장하에서의 담배 및 완두 원형질체 융합)

  • 서정우
    • Journal of Plant Biology
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 1986
  • Intra- and inter-specific protoplast fusion of tobacco (Nicotiana tabacum cv. Virginia 115) and pea (Pisum sativum cv. Sparkle) were carried out in highly inhomogeneous alternating electric fields. Under the electric field of alternating current (AC, sine wave), 600 V/cm and 800 kHz for tobacco protoplast, and 600 V/cm and 700 kHz for pea protoplasts, the protoplasts were aggregated in pearl chains. Intra-specific protoplast fusions were most effectively induced within the aggregates of tobacco and pea, respectively, by the additional application of a single high field pulse of direct current (DC, square wave) at 1 kV/cm for 50 $mutextrm{s}$. Inter-specific fusions between protoplasts of the two plants were most effectively induced in the electric field of 600 V/cm and 700 kHz, and square wave pulse at 1 kV/cm for 50 $mutextrm{s}$. The duration of the pulse over the electrical breakdown voltages was simulated from 1 to 100 $mutextrm{s}$ in both tobacco and pea protoplast. The yield of the electrofusion products was significantly high (above 60%), compared with that (20%) of the standard fusion method by polyethylene glycol (PEG) 4,000, and the viability of electrofused protoplasts was above 70%, but that of PEG-fused protoplasts 8~16%, when determined by Evan's blue staining method.

  • PDF

Investigation for Earth Resistance and Leakage Current of D/L (배전선로 접지저항 및 누설전류 실태조사)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Ha, Y.C.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.379-381
    • /
    • 2003
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. This causes induced voltages on underground metallic pipelines due to the power line currents. This could cause AC corrosion in the pipeline, which could in turn lead to disastrous accidents, such as gas explosion or oil leakage. This paper investigates for the limitation of induced voltage on the buried metal structures which is used in the inside and outside of the country. And then we measure the earth resistance and leakage current of 22.9kV distribution lines and pipe to soil potential of near pipelines in Seoul Korea. Hereby we can see the leakage current flowing through the earthing electrode have an effect on near pipelines.

  • PDF

The Research for a Structure of Current Limiter using a Phasic Similitude of Magnetic Circuit (자기회로의 위상학적 상사성을 이용한 전류제한기 구조에 관한 연구)

  • Ji, Geun-Yang;Min, Kyung-Il;Lee, Su-Won;Jang, Bong-Hwan;Moon, Young-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2128-2135
    • /
    • 2009
  • In this paper, current limiter using a magnetic switching which is based on magnetic flux change in the case of fault is proposed. This current limiter consists of iron-core and three parts of coils. One is the primary coil connected to the power system. Another is the secondary coil wound to the opposite direction of the primary coil's winding. The other is the secondary of the secondary coil which is a movable copper plate winding and located below the secondary coil. In the normal state, the magnetic flux produced in the primary and secondary coils flows to the opposite directions each other and becomes to be canceled out. Therefore the voltages induced between the coils are zero. In the case of a fault, at the moment of a fault occurrence recognition, the switch connected to a secondary coil is opened and the secondary of the secondary coil is pulled out to the outside of the iron-core. Then, magnetic flux becomes to flow through the iron-core. Accordingly, the voltage is induced between the both ends of the primary coil and makes the current reduced. Therefore it is possible to cut off the circuit breaker easily with the proposed current limiter. This paper analyzes the current limiting effects and the detailed results are given.

Experimental Investigation of Output Current Variation in Biased Silicon-based Quadrant Photodetector

  • Liu, Hongxu;Wang, Di;Li, Chenang;Jin, Guangyong
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.273-276
    • /
    • 2020
  • We report on the relationship between output current for quadrant photodetector (QPD) and bias voltage in silicon-based p-i-n (positive-intrinsic-negative) QPD examined using millisecond pulse laser (ms pulse laser) irradiation. The mechanism governing the relationship was further studied experimentally. The output current curves were obtained by carrying out QPD under different bias voltages (0-40 V) irradiated by ms pulse laser. Compared to other photodetectors, the relaxation was created in the output current for QPD which is never present in other photodetectors, such as PIN and avalanche photodetector (APD), and the maximum value of relaxation was from 6.8 to 38.0 ㎂, the amplitude of relaxation increases with bias value. The mechanism behind this relaxation phenomenon can be ascribed to the bias voltage induced Joule heating effect. With bias voltage increasing, the temperature in a QPD device will increase accordingly, which makes carriers in a QPD move more dramatically, and thus leads to the formation of such relaxation.

Heterogeneity of the SR-dependent Inward $Na^+-Ca^{2+}$ Exchange Current in the Heavily $Ca^{2+}-buffered$ Rat Ventricular Myocytes

  • Yoon, Kyung-Bong;Ahn, Sung-Wan;Ko, Chang-Mann
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.2
    • /
    • pp.101-110
    • /
    • 2004
  • Voltage-sensitive release mechanism was pharmacologically dissected from the $Ca^{2+}-induced\;Ca^{2+}\;release$ in the SR $Ca^{2+}$ release in the rat ventricular myocytes patch-clamped in a whole-cell mode. SR $Ca^{2+}$ release process was monitored by using forward-mode $Na^+-Ca^{2+}$ exchange after restriction of the interactions between $Ca^{2+}$ from SR and $Na^+-Ca^{2+}$ exchange within micro-domains with heavy cytosolic $Ca^{2+}$ buffering with 10 mM BAPTA. During stimulation every 10 s with a pulse roughly mimicking action potential, the initial outward current gradually turned into a huge inward current of $-12.9{\pm}0.5\;pA/pF$. From the inward current, two different inward $I_{NCX}s$ were identified. One was $10\;{\mu}M$ ryanodine-sensitive, constituting $14.2{\pm}2.3%$. It was completely blocked by $CdCl_2$ (0.1 mM and 0.5 mM) and by $Na^+-depletion$. The other was identified by 5 mM $NiCl_2$ after suppression of $I_{CaL}$ and ryanodine receptor, constituting $14.8{\pm}1.6%$. This latter was blocked by either 10 mM caffeine-induced SR $Ca^{2+}-depletion$ or 1 mM tetracaine. IV-relationships illustrated that the latter was activated until the peak in $30{\sim}35\;mV$ lower voltages than the former. Overall, it was concluded that the SR $Ca^{2+}$ release process in the rat ventricular myocytes is mediated by the voltage-sensitive release mechanism in addition to the $Ca^{2+}-induced-Ca^{2+}\;release$.