• Title/Summary/Keyword: Induced voltages

Search Result 167, Processing Time 0.028 seconds

Optimal Design of Smart Outrigger Damper for Multiple Control of Wind and Seismic Responses (풍응답과 지진응답의 다중제어를 위한 스마트 아웃리거 댐퍼의 최적설계)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.3
    • /
    • pp.79-88
    • /
    • 2016
  • An outrigger damper system has been proposed to reduce dynamic responses of tall buildings. In previous studies, an outrigger damper system was optimally designed to decrease a wind-induced or earthquake-induced dynamic response. When an outrigger damper system is optimally designed for wind excitation, its control performance for seismic excitation deteriorates. Therefore, a smart outrigger damper system is proposed in this study to make a control system that can simultaneously reduce both wind and seismic responses. A smart outrigger system is made up of MR (Magnetorheological) dampers. A fuzzy logic control algorithm (FLC) was used to generate command voltages sent for smart outrigger damper system and the FLC was optimized by genetic algorithm. This study shows that the smart outrigger system can provide good control performance for reduction of both wind and earthquake responses compared to the general outrigger system.

Corrosion Rate of Buried Pipeline by Induced Alternating Current (교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구)

  • Song H. S.;Kim Y. G.;Lee S. M.;Kho Y. T.;Park Y. S.
    • 한국가스학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.45-57
    • /
    • 2001
  • An alternating current (AC) corrosion using coupon has been studied. Coupons were applied in terms of AC voltage from high value to low value through the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion(: below -850mv vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relationship could be obtained statistically, in which AC corrosion rate increased linearly with effective AC current density and its slope was 0.619.

  • PDF

Development of Computer Program for Calculation of Induced Lightning Voltages on Overhead Multiconductor Systems (다상 가공선로의 유도뢰 전압 해석을 위한 프로그램 개발)

  • Lee, Yong-Han;Park, Dong-Wook;Lim, Yong Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.418-421
    • /
    • 1989
  • A program for numerical analysis of induced lightning surge is developed. The program first converts simultaneous differential equations into simultaneous difference equations for line sections without transition points, and calculates the line voltage and current by solving a determinant. It, then, calculates the line voltage and current at transition points by applying kirhhoffs law. This program is potentially useful in a wide range of applications for investigating the effect on distribution lines of lightning protection equipment such as lightning arresters and overhead ground wires.

  • PDF

Phenomenon of Power Interference and Screening Factor (전력유도 현상과 차폐계수)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Lee, Kyoung-Wook;Kim, Jae-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF

Analysis on Electrostatic Coupling around High speed Railway Feed System (고속철도 교류 급전계통 주변의 정전유도 영향 분석)

  • Myung, S.H.;Lee, J.B.;Kim, E.S.;Min, S.W.;Lee, J.W.;Lee, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1390-1392
    • /
    • 2000
  • In this paper, a numerical calculation method based on CSM has been described. The electric field must be nonuniform even close to railway feed system. In that case, to calculate induced voltage, this paper uses the mutual capacitances between a conductor and railway feed system. The induced voltages of a conductor located at point (height=4m, distance=8m) near by railway feed system are calculated from 370V to 668V.

  • PDF

Two-Dimensional Analytical Model for Deriving the Threshold Voltage of a Short Channel Fully Depleted Cylindrical/Surrounding Gate MOSFET

  • Suh, Chung-Ha
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.2
    • /
    • pp.111-120
    • /
    • 2011
  • A two-dimensional analytical model for deriving the threshold voltage of a short channel fully depleted (FD) cylindrical/surrounding gate MOSFET (CGT/SGT) is suggested. By taking into account the lateral variation of the surface potential, introducing the natural length expression, and using the Bessel functions of the first and the second kinds of order zero, we can derive potentials in the gate oxide layer and the silicon core fully two-dimensionally. Making use of these potentials, the minimum surface potential can be obtained to derive the threshold voltage as a closed-form expression in terms of various device parameters and applied voltages. Obtained results can be used to explain the drain-induced threshold voltage roll-off of a CGT/SGT in a unified manner.

Environmental Effect Analysis of Electromagnetic Induction in Express Electric Railway (고속 전철구간에서의 전력유도 환경 영향 분석)

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyung-Dong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.1
    • /
    • pp.19-23
    • /
    • 2010
  • The Electromagnetic Interference could occur due to power line on the telecommunication service. The Countermeasure is practised by legal law. Various affecting factors are described in the law. In this paper, an effect by pipeline especially in the ground, power feeding plant, and curved railway sector is analyzed as environmental factors which are not included in the law. By the practical measurement, it appears that the measured voltages on the spots with underground pipeline are grouped into lower voltage level, induced voltage tends to be high near power feeding plant, and also in the curved railway line. These analytical results can be meaningly considered in the application of countermeasure.

  • PDF

Experimental Analysis of Normal Zone Propagation in the Jointed YBCO Coated Conductors

  • Chang, Ki-Sung;Kim, Young-Jae;Jo, Hyun-Chul;Jang, Jae-Young;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.2
    • /
    • pp.1-4
    • /
    • 2010
  • Normal zone propagation (NZP) within jointed YBCO coated conductors (CC) was analyzed experimentally. The joint between CC tapes were conducted by lap joint method and the characteristics of the jointed CC tapes measured from V-I curve. NZP was induced by thermal heaters attached to two points of the jointed CC tapes; the voltages across the jointed CC tapes were measured and recorded. NZP induced by each heater point is compared in point of protection of CC tapes and magnet. This study about NZP of the jointed tapes may be useful to make a magnet system with several coils using YBCO CC.

Prebreakdown Corona Discharge of Point-to-Plane Gap in $SF_6$ Gas ($SF_6$ 가스중에서 침대평판간극(針對平板間隙)의 전구(前驅)코로나 방전(放電))

  • Paek, Yong-Hyun;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.980-982
    • /
    • 1992
  • This paper deals with the dielectric behaviors of $SF_6$ gas and prebreakdown growth caused by lightning impulse voltages In inhomogeneous field perturbed with a fixed needle-shaped protrusion on the electrode. The measuring interpretation of the external current induced by moving charges is described. The temporal growth of prebreakdown is observed by using a shunt and photomultiplier. The prebreakdown processes are initiated by the first streamer corona at a needle protrusion, the flashover of the main gap in the positive polarity is very sensitive to the local field and propagates into the gap with the leader mechanism. It Is found that the dependence of the prebreakdown phenomena on the polarity of applied voltages is caused by the effect of space charges. In addition, the proposed measuring techniques are very useful to perform the measurements of avalanche currents, corona discharges in inhomogeneous fields and partial discharges in voids.

  • PDF

Hysteresis Phenomenon of Hydrogenated Amorphous Silicon Thin Film Transistors for an Active Matrix Organic Light Emitting Diode (능동형 유기 발광 다이오드(AMOLED)에서 발생하는 수소화된 비정질 실리콘 박막 트랜지스터(Hydrogenated Amorphous Silicon Thin Film Transistor)의 이력 (Hysteresis) 현상)

  • Choi, Sung-Hwan;Lee, Jae-Hoon;Shin, Kwang-Sub;Park, Joong-Hyun;Shin, Hee-Sun;Han, Min-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.112-116
    • /
    • 2007
  • We have investigated the hysteresis phenomenon of a hydrogenated amorphous silicon thin film transistor (a-Si:H TFT) and analyzed the effect of hysteresis phenomenon when a-Si:H TFT is a pixel element of active matrix organic light emitting diode (AMOLED). When a-Si:H TFT is addressed to different starting gate voltages, such as 10V and 5V, the measured transfer characteristics with 1uA at $V_{DS}$ = 10V shows that the gate voltage shift of 0.15V is occurred due to the different quantities of trapped charge. When the step gate-voltage in the transfer curve is decreased from 0.5V to 0.05V, the gate-voltage shift is decreased from 0.78V to 0.39V due to the change of charge do-trapping rate. The measured OLED current in the widely used 2-TFT pixel show that a gate-voltage of TFT in the previous frame can influence OLED current in the present frame by 35% due to the change of interface trap density induced by different starting gate voltages.