• Title/Summary/Keyword: Induced earthquake

Search Result 376, Processing Time 0.026 seconds

Vibration Control of Cantilever Beams using Magnetic Damping (자기감쇄를 이용한 외팔보의 진동제어)

  • 이종세
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.259-264
    • /
    • 1999
  • The magnetoelastic interaction between electrically conducting structures and magnetic fields is suggested to be used as a possible means for vibration suppression mechanism in structural control. Effectiveness of the active control mechanism is demonstrated by an experiment which is performed to examine the basic tenets of magnetically induced vibration and magnetoelastic damping of a cantilevered beam virating in the presence of magnetic fields Experimental results show that the feedback control scheme works effectively. Several strategies are suggested to improve the controllability using the magnetic damping.

  • PDF

Dynamic Characteristics and Isolation Performance of Isolation Table System (면진 테이블 시스템의 동적 특성 및 면진성능)

  • ;;;Kurabayashi
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.67-74
    • /
    • 2001
  • Structural engineers lately have an interest in the safety for equipments and facility in buildings subjected to earthquake. The stability of cultural assets was not considered for the earthquake induced vibration, while the integrity of structure has been considered through the resistant earthquake design. The purpose of this study aimed to analyze the behavior of isolation device named as \"Isolation table system\" and to evaluate its isolation performance through the experiment study. Isolation table is one of isolation systems to reduce the vibration which was transferred from slab to exhibition table. Experimental result shows that isolation table can reduce the vibration by 80-90% and its behavior is very stable within its maximal stroke.al stroke.

  • PDF

Rotational capacity of pre-damaged I-section steel beams at elevated temperatures

  • Pantousa, Daphne;Mistakidis, Euripidis
    • Steel and Composite Structures
    • /
    • v.23 no.1
    • /
    • pp.53-66
    • /
    • 2017
  • Structures submitted to Fire-After-Earthquake loading situations, are first experiencing inelastic deformations due to the seismic action and are then submitted to the thermal loading. This means that in the case of steel framed structures, at the starting point of the fire, plastic hinges have already been formed at the ends of the beams. The basic objective of this paper is the evaluation of the rotational capacity of steel I-section beams damaged due to prior earthquake loading, at increased temperatures. The study is conducted numerically and three-dimensional models are used in order to capture accurately the nonlinear behaviour of the steel beams. Different levels of earthquake-induced damage are examined in order to study the effect of the initial state of damage to the temperature-evolution of the rotational capacity. The study starts with the reference case where the beam is undamaged and in the sequel cyclic loading patterns are taken into account, which represent earthquakes loads of increasing magnitude. Additionally, the study extends to the evaluation of the ultimate plastic rotation of the steel beams which corresponds to the point where the rotational capacity of the beam is exhausted. The aforementioned value of rotation can be used as a criterion for the determination of the fire-resistance time of the structure in case of Fire-After-Earthquake situations.

Distributed crack sensors featuring unique memory capability for post-earthquake condition assessment of RC structures

  • Chen, Genda;McDaniel, Ryan;Sun, Shishuang;Pommerenke, David;Drewniak, James
    • Smart Structures and Systems
    • /
    • v.1 no.2
    • /
    • pp.141-158
    • /
    • 2005
  • A new design of distributed crack sensors based on the topological change of transmission line cables is presented for the condition assessment of reinforced concrete (RC) structures during and immediately after an earthquake event. This study is primarily focused on the performance of cable sensors under dynamic loading, particularly a feature that allows for some "memory" of the crack history of an RC member. This feature enables the post-earthquake condition assessment of structural members such as RC columns, in which the earthquake-induced cracks are closed immediately after an earthquake event due to gravity loads, and are visually undetectable. Factors affecting the onset of the feature were investigated experimentally with small-scale RC beams under cyclic loading. Test results indicated that both crack width and the number of loading cycles were instrumental in the onset of the memory feature of cable sensors. Practical issues related to dynamic acquisition with the sensors are discussed. The sensors were proven to be fatigue resistant from shake table tests of RC columns. The sensors continued to show useful performance after the columns can no longer support additional loads.

Seismic Fragility Analysis of Buildings With Combined Shear Wall-Damper System (벽체-감쇠 복합시스템을 갖는 건물의 지진취약도 분석)

  • Rajibul Islam;Sudipta Chakraborty;Kong, ByeongJin;Kim, Dookie
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.91-99
    • /
    • 2023
  • Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.

Optimal Design of Smart Outrigger Damper for Multiple Control of Wind and Seismic Responses (풍응답과 지진응답의 다중제어를 위한 스마트 아웃리거 댐퍼의 최적설계)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.3
    • /
    • pp.79-88
    • /
    • 2016
  • An outrigger damper system has been proposed to reduce dynamic responses of tall buildings. In previous studies, an outrigger damper system was optimally designed to decrease a wind-induced or earthquake-induced dynamic response. When an outrigger damper system is optimally designed for wind excitation, its control performance for seismic excitation deteriorates. Therefore, a smart outrigger damper system is proposed in this study to make a control system that can simultaneously reduce both wind and seismic responses. A smart outrigger system is made up of MR (Magnetorheological) dampers. A fuzzy logic control algorithm (FLC) was used to generate command voltages sent for smart outrigger damper system and the FLC was optimized by genetic algorithm. This study shows that the smart outrigger system can provide good control performance for reduction of both wind and earthquake responses compared to the general outrigger system.

Reduction Effect of liquefaction by Vibro-Replacement Stone Columns (진동치환 스톤칼럼공법에 의한 액상화 저감 효과)

  • Lee, Song;Chae, Jum-Sik;Park, Sang-Kuk
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.443-450
    • /
    • 2001
  • This paper shows the reduction effect of tile earthquake-induced liquefaction potential of soils that improved by Vibro-Replacement Stone Columns. The Vibro-Replacement Stone Columns method transforms soft cohesive soils into a composite mass of compacted granular or crushed stone columns by using vibrating equipment and water jets. This study investigated and analyzed the behavior of the stone columns and composite ground using the results of in situ test and measurement at the job-site. This paper shows the evaluation of the earthquake-induced liquefaction potential of soils using in situ test. There are different types of in situ test used in the evaluation the liquefaction potential. In the particular study the Standard penetration test, and Cone penetration test were used. The N value of Standard Penetration test has been used all over for a very long time. The evaluation of the liquefaction of soil was performed using the worldwide renewed Cone penetration test

  • PDF

A Seismic Excitation on Floating Platforms

  • Y.K.,Chung
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.16 no.3
    • /
    • pp.21-24
    • /
    • 1979
  • The method of computing a hydrodynamic force induced by a random seismic motion of boundary is presented and a sway force acting on a platform during an earthquake is shown.

  • PDF

GPS Ionospheric Perturbations Following ML ≥ 5.0 Earthquakes in Korean Peninsula (한반도내 규모 5.0 이상의 지진에 의한 GPS 전리층 변동)

  • Sohn, Dong-Hyo;Park, Sun-Cheon;Lee, Won-Jin;Lee, Duk Kee
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_4
    • /
    • pp.1531-1544
    • /
    • 2018
  • We detected the coseismic ionospheric disturbance generated by the earthquakes of magnitude 5.0 and greater in Korean Peninsula. We considered the seismic events such as Gyeongju earthquake in September 2016 with magnitude 5.8, the Pohang earthquake in November 2017 with magnitude 5.4, and the underground nuclear explosion from North Korea in September 2017 with magnitude 5.7. Although all GPS stations were not detected, the ionospheric disturbance induced by these earthquakes occurred approximately 10-30 minutes and 40-60 minutes after the events. We inferred that the time difference within each variation is due to the different focal depth and the geometry of epicenter, satellite, and GPS station. In the case of the Gyeongju earthquake, the earthquake had relatively deeper depth than the other earthquakes. However, the seismic magnitude was bigger and it occurred at nighttime when the ionospheric activity was stable. So we could observe such anomalous variations. It is considered that the ionospheric disturbance caused by the difference in velocity of the upward propagating waves generated by earthquake appears more than once. Our results indicate that the detection of ionospheric disturbances varies depending on the geometry of the GPS station, satellite, and epicenter or the detection method and that the apparent growth of amplitude in the time series varies depending on the focal depth or the site-satellite-epicenter geometry.

Behavior Analysis on Earthquake-Induced Deformation of Quay Wall and Apron in Ground at Youngilman Port Considering Drainage Condition Using FEM Analysis (FEM 해석에 의한 지반배수조건에 따른 지진 시 영일만항의 케이슨식 안벽 및 배후지의 거동 분석)

  • Lee, Hak-Ju;Kang, Gi-Chun;Hwang, Woong-Ki;Lee, Min-Sun;Kim, Tae-Hyung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.386-394
    • /
    • 2019
  • In this study, according to drainage condition (undrained and drained) in ground, the settlement and horizontal displacement of caisson quay wall and apron in Yeongilman port due to excess pore water pressure in ground induced by the magnitude 5.4 earthquake in Pohang on November 15, 2017. In general, seismic response analysis was carried out under undrained drainage condition, but in this study, drain drainage analysis was conducted to estimate displacement during earthquake as well as an additional displacement due to dissipation of excess pore water pressure after earthquake. The result of after earthquake can not be known under undrained drainage condition. Results cleary showed that the behavior of structure and ground was dependent on drainage condition in ground. Especially, based on the drained drainage condition, the additional displacement was clearly detected due to dissipation of excess pore water pressure after earthquake. Which indicates that both results are different to drainage condition in ground, and therefore, drainage condition analysis is necessary to accurately estimate the behavior of ground and structure in seismic response analysis.