• Title/Summary/Keyword: Induced current

Search Result 2,692, Processing Time 0.029 seconds

A Basic Study on the Low Drift Flux Meter by Using a Peltier Device (펠티어 소자를 사용한 Low Drift Flux Meter의 기초연구)

  • Kim, Chul-Han;Heo, Jin;Shin, kwang-Ho;Sa-Gong, Geon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.11
    • /
    • pp.912-916
    • /
    • 2001
  • Fluxmeter is a measuring instrument the magnetic flux intensity by means of an integration of the voltage induced to a search coil to unit time. It also is required to a precise integrator since the voltage induced to a search coil has a differential value of the flux ${\Phi}$ to unit time. In this study, a bias current which is a main problem of the integrator in a drift troublesome depending on the temperature of a FET is investigated. We have confirmed that the temperature dependence of both the bias current of a integrator using the FET and the reversal saturated current of the minor carrier in a P-N junction of a semiconductor were the same. The property of a commercial integrator goes rapidly down with increasing temperature. The bias current of a FET is increased twice as much with 10$^{\circ}C$ increment. As a result, the low drift integrator could be developed by setting the lower temperature up with a pottier device.

  • PDF

The Effect of Microcurrent Stimulation on Immediately Early Gene in Pain Induced Model (실험적 통증유발 모델에서 조기발현 유전자에 대한 미세전류자극의 효과)

  • Kim Gye-Yeop;Kim Tae-Youl;Oh Myung-Hwa;Kim Sun-Eun;Cheong Mee-Sun;Suh Young-Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.9-21
    • /
    • 2004
  • The purpose of study is that we will observe the change of c-fos with the immunohistochemistry method and then we will study the effect of micro current stimulation following the frequency after inducing pain to rats with capsaicin. Rat were classified to SD and they have growed for 8 weeks. We classify to four groups, ordinal group is used in experiment I, the group which we induce pain is used in experiment II, the application group which we induce pain and then the high frequency micro current stimulation is used in experiment III, the application group which we induce pain and then the low frequency micro current stimulation is used in experiment IV, we get the following result. Compare with experiment II, experiment III, and experiment IV from acute pain modal in the immunohistochemistry experiment which has c-fos protein as an antigen, c-fos immunoreactive positive neurons significantly after induced pain for two hours(p<0.001). According to these results, from rats induced pain, micro current stimulation effect to reducing pain, but following frequency micro current stimulation theraphy isn't different from immunoreactive c-fos

  • PDF

Investigation on the Design Wave Forces for Ear-do Ocean Research Station II: Fluid Force in the Breaking Wave Field (이어도 종합해양과학기지에 대한 설계파력의 검토 II: 쇄파역에서의 유체력)

  • 전인식;심재설;최성진
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.12 no.4
    • /
    • pp.168-180
    • /
    • 2000
  • In the Part I, the three dimensional model testing with NNW deep water wave direction gave the results such that the occurrence of breaking waves over the peak of Ear-Do caused very small wave height at the structure position. But the measured wave forces were rather greater than the calculated forces based on deep water wave height. Furthermore, It was also perceived that the time series of the forces looked like corresponding to the case that waves were superimposed by an unidirectional current. In the present Part II, the current is presumed to be a flow secondly induced by breaking waves, and an extensive study to clarify the current in a quantitative sense is performed through numerical analysis and hydraulic experiment. The results showed that a strong circulation can surely occur in the vicinity of the structure due to radiation stress differentials given by the breaking waves. It was also recognized that the velocity of the induced current varied with the magnitude of energy dissipation rate introduced in the numerical analysis. The numerical analysis was tuned adjusting the dissipation rate so that the calculated wave field could closely match with the experimental results of Part I. The fluid force (in prototype) for the optimal match showed approximately 2.2% increased over the calculated value based on the deep water wave height (24.6m) whereas the force corresponding to the average of the experimental values showed the increase of about 13.0%.

  • PDF

Verification on the Calculated Geoelectric Field on Power Grid during Geomagnetic Disturbances (지자기 교란으로 인한 전력망 유도전기장 예상값 검증)

  • Park, Sung Won;Yoo, Chung-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.94-100
    • /
    • 2015
  • Coronal mass ejection (CME) released due to solar flare explosion cause geomagnetic disturbance. The induced current by massive geomagnetic disturbance can cause damage to the transformer. The calculated geoelectric field is a major parameter of the geomagnetically induced current (GIC). The method applying a Fourier transform has a high accuracy but it needs all data measured for 24 hours. And the other method applying a integral equation can calculate in real time but it requires to check an accuracy. To reduce the gap between the calculated results of two methods, it adjusts the integration section. As a result, the correlation between two calculated geoelectric fields is high, and the event time and direction of the calculated current is the same as that of the measured current, and it's accuracy rate is above 92 percent.

Analysis of Shielding Characteristics for Induction Phenomenon Attenuation of Large Capacity Wireless Power Transmission Environment (대용량 무선전력전송 환경 유도현상 감쇄를 위한 차폐 특성 분석)

  • Chae, Dong-Ju;Kim, Young-Seok;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo;Hong, Seong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1844-1851
    • /
    • 2017
  • As the capacity of the wireless power transmission increases, a higher supply current which may induce current in nearby conductive parts requires. Induced current may affect electric shock to the human body and malfunction of the electrical equipment. In order to prevent such induced phenomena as a risk factor, shielding is required between the source of the wireless power transmission and the conductive parts. The resonance frequency for the large capacity wireless power transmission has the wavelength of several hundred meters, so most environments are included in the near-field area. By wave impedance, the electric field has higher density in the near-field area and needs to be analyze for protecting. For this purpose, it is necessary to select a substance having a larger electric conductivity and optimized shielding structure. In this paper, an aluminum base shielding structure was presented to conduct experiments on thickness, position, and heat dissipation. In the 35 kW, 60 kHz environments, the optimized 5T Al base shielding structure attenuates the induced current to 43 %.

Measurement & Analysis of Transport Current AC loss in Coated Conductor Bifilar Structure (Coated Conductor의 Bifilar 구조에서의 통전 교류 손실 측정 및 해석)

  • Bang, J.S.;Park, D.K.;Sim, K.D.;Jang, K.S.;Yang, S.E.;Ahn, M.C.;Kang, H.K.;Seok, B.Y.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 2007
  • Superconductor is weak in AC condition. Bifilar geometry provides a solution to reduce AC loss. Bifialr geometry is piled up or wound with more than two layers. When a layer of superconductor abuts on other layers, AC loss is affected by not only self-field, but also magnetic field induced by adjacent layers. In this study, two superconductors are piled up as a series connection so that current flows in different directions. By this method, magnetic field is cancelled. If magnetic field is cancelled, AC loss is reduced. To compare AC loss with respect to piling method, we measured the AC loss difference between the case facing each other with substrate side and the case facing with YBCO side. Measured AC loss is compared with one-way current flow single layer AC loss. In addition, we analyzed how much AC loss was increased, or reduced. All results were compared with those calculated with Norris equation. By this experiment, we concluded that distance between two wires is the important cause of AC loss. The distance between two wires affects magnetic field reduction in YBCO and induced current flow on substrate side.

A Study on the Loop Current Induced by Voltage Phase Difference Substations during Parallel Feeding under the Alternating Current AT Electric Power Feeding Method (교류 AT급전방식에서 병렬급전시 변전소간 전압위상차에 의한 루프전류에 관한 연구)

  • Park, Jae-Seok;Song, Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1997-2004
    • /
    • 2011
  • The $2{\times}25kv$ AT electric power feeding method in the A.C. electric train adopts the one-phase power feeding method as the standard due to a voltage phase difference, and the distance between the two neighboring substations is 50km due to voltage drop. The one-phase power feeding method makes the system operation feasible, while making it unfavorable for power supply. Moreover, railroad involves large-capacity single-phase load, and if it is expected to continue to rise, it is necessary to research on measures to stabilize the supply of power to railroad cars with the existing facilities. In this study, a parallel power feeding method between neighboring substations is proposed to stabilize the supply of electric power to electric railroad cars under the 2*25kv AT power feeding method and the loop current induced by voltage phase difference between the two neighboring substations during parallel power feeding is investigated.

  • PDF

Development of Equivalent Magnetic Circuit Network Method for 3 Dimentional Eddy current Analysis (3차원 와전류 해석을 위한 등가자기회로방법의 개발)

  • Hur, Jin;Hong, Jung-Pyo;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.228-233
    • /
    • 2002
  • A computational method for analysis of the 3 dimensional electro-magnetic induction problems has been developed. The developed method is capable of modeling the induced current and analyzing its characteristics using only scalar Potential at each node. A benchmark model of asymmetrical conductor with a hole is analyzed to verify the application of the developed method. The calculated value of magnetic flux density are compared with the measured value, and the results indicate that the developed method is valid. Also, Comparing with 3-D finite element method (FEM) results, we conformed effectiveness of the developed method for the accuracy and computation times.

Degradation Behavior of 850 nm AlGaAs/GaAs Oxide VCSELs Suffered from Electrostatic Discharge

  • Kim, Tae-Yong;Kim, Tae-Ki;Kim, Sang-In;Kim, Sang-Bae
    • ETRI Journal
    • /
    • v.30 no.6
    • /
    • pp.833-843
    • /
    • 2008
  • The effect of forward and reverse electrostatic discharge (ESD) on the electro-optical characteristics of oxide vertical-cavity surface-emitting lasers is investigated using a human body model for the purpose of understanding degradation behavior. Forward ESD-induced degradation is complicated, showing three degradation phases depending on ESD voltage, while reverse ESD-induced degradation is relatively simple, exhibiting two phases of degradation divided by a sudden distinctive change in electro-optical characteristics. We demonstrate that the increase in the threshold current is mainly due to the increase in leakage current, nonradiative recombination current, and optical loss. The decrease in the slope efficiency is mainly due to the increase in optical loss.

  • PDF

Effects of Electric Current on Flowering in Pharbitis and Floral Stimulus activity in the Phloem Exudate of Cotyledons

  • Jueson Maeng
    • Journal of Plant Biology
    • /
    • v.37 no.2
    • /
    • pp.159-166
    • /
    • 1994
  • Direct current (DC) applied to cotyledons during a 16 h inductive dark period inhibited the flowering in the short-day plant, Pharbitis nil Choisy cv. Violet. The inhibitory effect of DC was more profound when the current flowed from roots to cotyledons, showing its polarity-dependent action. The second half on the inductive dark period was more sensitive to DC stimulus. The flowering was significantly depressed only when DC stimuli were applied to the translocation path of the floral stimulus from the induced cotyledon to the apex, suggesting that the transport of floral stimulus was damaged by the DC treatment. The vegetative apex culture bioassay system showed that a significant level of the floral stimulus activity existed in the phloem exudate from the cotyledons which would fail to form their own floral buds. These results strongly support the hypothesis that DC partially impede, at least temporarily, the transmission path of the floral stimulus from florally-induced cotyledon to the apex, rather than depressing in situ synthesis of the floral stimulus.

  • PDF