• 제목/요약/키워드: Induced air

검색결과 1,070건 처리시간 0.025초

항공교통관제사의 피로.스트레스 요인 (Fatigue and Stress of Air Traffic Controllers in Korea)

  • 윤용식;이수란;손영우
    • 한국항공운항학회지
    • /
    • 제20권1호
    • /
    • pp.76-85
    • /
    • 2012
  • Air traffic controllers often experience fatigue and stress on the job due to work-related factors. Performance impairment resulting from fatigue and stress is an important concern for aviation safety. The goal of this research was to investigate fatigue and stress factors for air traffic controllers. The research involved an extensive literature review of fatigue and stress in the air traffic control environment and surveyed fatigue and job stress level of Korean air traffic controllers compared to other occupation groups. Results of survey showed that fatigue and stress levels of air traffic controllers were significantly higher than other occupation groups. Specially air traffic controllers reported that night work created high level of fatigue and perceived that physical environment and job demand induced high level of stress. In addition, implications for fatigue and stress management were discussed.

항공교통문화지수 개발에 관한 연구 (A study on the development for an air transportation cultural index)

  • 이강석
    • 한국항공운항학회지
    • /
    • 제13권3호
    • /
    • pp.61-72
    • /
    • 2005
  • The main purpose of this study is to develop air transportation cultural index which is able to estimate the level of them. Generally Speaking, air transportation cultural, a compound word of 'air transportation' and 'culture', is a substantial entity consisting knowledge, art, morality, legality, cultivation, customs, and etc, which comes from aircraft operation sector, airport operation/management sector and user sector. They are classified in a primary scope, as aircraft operation sector relating to flight operation, airport operation/management sector and user sector. The research and analysis were taken approximately 4 months, from June 2004 to October 2004. To evaluate the index, the detailed item for three categories were chosen and quantified. The grades for each items were induced from calculation formula for air transportation cultural index by applying weight values. The final grade of Korea's air transportation cultural index recorded 63.19 points.

  • PDF

낙동강 하천 토지이용 변화에 따른 미세규모 기상 요소의 변동에 관한 수치 연구 (Numerical Study on the Changes in Microscopic Meteorological Elements due to Land Use Variations in the Nakdong River Basin)

  • 김은지;이순환
    • 한국환경과학회지
    • /
    • 제25권12호
    • /
    • pp.1597-1611
    • /
    • 2016
  • A numerical assessment using mesoscale-CFD (computational fluid dynamics) coupled A2C (atmosphere to CFD) model was carried out to analyze the variation of microscopic air flow pattern due to the construction of the Chilgok barrage in the Nakdong River. Scenarios with air flow patterns were classified into pre- and post-construction. The increased width of the river due to the construction of the Chilgok barrage induced obvious changes in moisture and the thermal environment around the river. However, air temperature variation was restricted within an area along the windward side in the numerical assessment. The impact of barrage construction on air temperature tends to be stronger during the nighttime than the daytime. It also stronger during the winter than the summer. In the simulation, the convergence of mesoscale wind is more pronounced after barrage construction than before. This is caused by the change of heat flux pattern induced by the widening of the river. Although this work is a case study with restricted atmospheric stability conditions that has several limitations in the numerical simulations, the impacts of the land-use changes brought about by the construction of the barrage in the river acceptable.

LPG 액상분사 엔진에서 아세톤 PLIF를 이용한 연료분포 측정기법 연구 (Acetone PLIF for Fuel Distribution Measurements in Liquid Phase LPG Injection Engine)

  • 오승묵;박승재;허환일;강건용;배충식
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.74-82
    • /
    • 2004
  • Planar laser-induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Acetone PLIF is chosen because fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone PLIF is applied to measure quantitative air excess ratio distribution in an engine fueled with LPG. Acetone is excited by KrF excimer laser (248nm) and its fluorescence image is acquired by ICCD camera with a cut-off filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile is suggested. Raw images are divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which is taken by a calibration process, are converted to air excess ratio distribution. This investigation shows instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

Numerical Study on NO Emission with Flue Gas Dilution in Air and Fuel Sides

  • Cho Eun-Seong;Chung Suk Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제19권6호
    • /
    • pp.1358-1365
    • /
    • 2005
  • Flue gas recirculation (FGR) is widely adopted to control NO emission in combustion systems. Recirculated flue gas decreases flame temperature and reaction rate, resulting in the decrease in thermal NO production. Recently, it has been demonstrated that the recirculated flue gas in fuel stream, that is, the fuel induced recirculation (FIR), could enhance much improved reduction in NO per unit mass of recirculated gas, as compared to conventional FGR in air. In the present study, the effect of dilution methods in air and fuel sides on NO reduction has been investigated numerically by using $N_2$ and $CO_2$ as diluent gases to simulate flue gases. Counterflow diffusion flames were studied in conjunction with the laminar flamelet model of turbulent flames. Results showed that $CO_2$ dilution was more effective in NO reduction because of large temperature drop due to the larger specific heat of $CO_2$ compared to $N_2$. Fuel dilution was more effective in reducing NO emission than air dilution when the same recirculation ratio of dilution gas was used by the increase in the nozzle exit velocity, thereby the stretch rate, with dilution gas added to fuel side.

Laser-Induced Fluorescence spectroscopy을 이용한 환경 중 PAHs 화합물의 실시간 현지 모니터링 (In-situ Monitoring of PAHs in the Environment Using Laser-Induced Fluorescence Spectroscopy)

  • 이철규;;김영준
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.358-359
    • /
    • 2001
  • PAHs는 불완전연소 과정과 주유소나 타르 생산공장 주변에서 발생하는데 돌연변이와 발암의 잠재력으로 인하여 특별한 관심이 요구되는 것들이고 US-EPA에서도 우선 오염물질로 선정되었다. PAHs를 검출하는 훌륭한 기술들이 존재하나, 이러한 기술들은 연속적인 모니터링이 요구되거나 많은 수의 샘플을 분석해야할 경우에 상당한 양의 비용과 시간이 요구된다. 그러나 분광학 기술을 바탕으로 한 Laser-Induced Fluorescence(LIF) spectroscopy를 이용한 방법은 실시간으로 연속적인 측정을 가능하게 할 뿐 아니라 여러 가지 PAHs, 유류오염물질 등의 물질을 동시에 측정할 수 있다. (중략)

  • PDF

철도차량 객차내 오염물질의 분포경향에 관한 전산해석 (Distribution of Pollutant on the Indoor Air of Passenger Car)

  • 소진섭;전철균;박찬수;최주석
    • 한국연소학회지
    • /
    • 제8권2호
    • /
    • pp.7-16
    • /
    • 2003
  • The transfer of air pollutants between passenger room and service room in train are investigated by the computational analysis. The effects of service room temperature, inlet velocity, initial concentration and heating are studied. The flow induced by the difference of density between two rooms is found to take the major role in transfer of polluted air. Low temperature of service room enhances the polluted air flow into passenger room along the floor. Exhaust fan above the door between two rooms is not effective for this case. Strong inlet flow is found to suppress polluted air flow from service room. The heating of passenger room can promote air pollution.

  • PDF

CFD 해석을 통한 하이브리드 공조시스템의 인체 온열감의 불균일성에 관한 연구 (Study on Non-uniform Thermal Comfort in Hybrid Air-Conditioning System with CFD Analysis)

  • 남유진;성민기;송두삼
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.216-222
    • /
    • 2011
  • Recently, hybrid air-conditioning system has been proposed and applied to achieve building energy saving. One example is a system combining radiation panel with natural wind-induced cross-ventilation. However, few research works have been conducted on the non-uniformity of thermal comfort in such hybrid air-conditioning system. In this paper, both thermal environment and non-uniform thermal comfort of human thermal model under various air-conditioning system, including hybrid system, were evaluated in a typical office room using coupled simulation of computation fluid dynamics, radiation model and a human thermal model. The non-uniformity of thermal comfort was evaluated from the deviation of surface temperature of human thermal model. Flow fields and temperature distribution in each case were represented.

대공간 열환경 특성에 관한 수직순환기류의 영향 (Effect of the Vertical Air Circulation on the Thermal "Environment in a Large Space)

  • 김경환;강석윤;최충현;조영진;이재헌;오명도
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.581-588
    • /
    • 2000
  • This paper describes the effect of vertical air circulation on the thermal environment in an airport passenger terminal with induced flow by jet fans. In comparing the level of thermal comfort at the breathing line of 1.5 m in height, the results from the two models with or without the vertical air circulation, show that the average PPD is 8% in the former and 23% in the latter, respectively. It is thought that vertical air circulation lends to improved thermal comfort for human in respect of ventilation in a large space.

  • PDF

공동주택용 하이브리드 환기설비에 관한 연구 (A Study of Hybrid Ventilation System applying to an Apartment House)

  • 이성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1137-1143
    • /
    • 2006
  • The purpose of this research lays on examining the adequacy of the hybrid ventilation system. The hybrid ventilation system must satisfy the next to be used. Firstly, the cold-draft phenomenon must not exist in the occupied zone. Secondly, the condensation must not happen on the surfaces of vents. Thirdly, the flow of make-up air must be happened in an each space by exhausted air of a rest room and living room. We used an examination and CFD method to verify these. Trough the examination of air-vents, We confirmed that the cold-draft to be induced by make-up air does not happen and could not find the condensation in the limits of outdoor temperature higher than 265K. Through CFD simulation, We confirmed that the rapid temperature change existed only within 0.5m the occupied zone and the flow of air was happened in an each space by only exhausted air in the rest room and living room. Consequently, the hybrid system is possible method to an apartment house.

  • PDF