• Title/Summary/Keyword: Indoor quality

Search Result 1,349, Processing Time 0.034 seconds

Simulation and Health Risk Evaluation of Indoor Air Quality Changes by Ventilation System in New Apartment (신축아파트 환기방식에 따른 실내공기질 변화와 이에 대한 시뮬레이션 및 건강 위해성 평가)

  • Bao, Wei;Jung, Jaeyoun;Jeong, Insoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.23 no.4
    • /
    • pp.38-45
    • /
    • 2021
  • In this study, air quality conditions were identified and analyzed in real time, at the same time, living habits and ventilation methods were maintained in the daily life of residents, and thus, this present study focuses on the lifestyles of residents. Previous studies showed a difference from this study, focusing on the study on the effects of changes in indoor air quality on human health according to the indoor air quality process test standards of the Ministry of Environment. Formaldehyde concentrations exceeded all ventilation standards, but satisfied the organic standards of the Ministry of Environment when ventilation devices and air purifiers were activated. As such, it was investigated that a large amount of formaldehyde emission in the condo is initially ventilated, but a certain concentration is maintained. The change in PM2.5 concentration according to the ventilation method showed a clear difference. As a result of simulating indoor air flow during natural ventilation, the effects of wind speed and wind direction affect the flow rate of indoor air, and indoor polluted air is stagnant even in the presence of wind and is not completely discharged. When the risk assessment results are averaged on the day of measurement, the trends of change between adults and children are almost equivalent, but the results address that children are more sensitive to risk than adults.

A Study on the Improvement of Comfortable Living Environment by Using real-time Sensors

  • KIM, Chang-Mo;KIM, Ik-Soo;SHIN, Deok-Young;LEE, Hee-Sun;KWON, Seung-Mi;SHIN, Jin-Ho;SHIN, YongSeung
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.4
    • /
    • pp.19-31
    • /
    • 2022
  • Purpose: This study was conducted to identify indoor air quality in various living spaces using sensors that can measure noise, vibration, fine dust, and odor in real time and to propose optimal indoor air quality maintenance management using Internet of Things(IoT). Research design, data and methodology: Using real-time sensors to monitor physical factors and environmental air pollutants that affect the comfort of the residential environment, Noise, Vibration, Atmospheric Pressure, Blue Light, Formaldehyde, Hydrogen Sulfide, Illumination, Temperature, Ozone, PM10, Aldehyde, Amine, LVOCs and TVOCs were measured. It were measured every 1 seconds from 4 offices and 4 stores on a small scale from November 2018 to January 2019. Results: The difference between illuminance and blue light for each measuring point was found to depend on lighting time, and the ratio of blue light in total illumination was 0.358 ~ 0.393. Formaldehyde and hydrogen sulphide were found to be higher than those that temporarily attract people in an indoor office space that is constantly active, requiring office air ventilation. The noise was found to be 50dB higher than the office WHO recommendation noise level of 35 ~ 40dB. The most important factors for indoor environmental quality were temperature> humidity> illumination> blue light in turn. Conclusions: Various factors that determine the comfort of indoor living space can be measured with real-time sensors. Further, it is judged that the use of IoT can help maintain indoor air quality comfortably.

Effects of Housing Systems on Behaviour, Performance and Welfare of Fast-growing Broilers

  • Zhao, Zi-Guang;Li, Jian-Hong;Li, Xiang;Bao, Jun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.1
    • /
    • pp.140-146
    • /
    • 2014
  • This experiment aimed to evaluate the effects of different housing systems on behavioral activities, welfare and meat quality of fast-growing broilers. Two hundred broilers were allocated into two housing systems: indoor housing vs indoor with outdoor access. Their general behavior (feeding, drinking, fighting, standing, lying, walking, investigating, dust-bathing and preening) was observed, and tonic immobility, fluctuating asymmetry of legs and wings were measured, and meat quality was analyzed. The results showed that the indoor-housed broilers with outdoor access had significant higher standing, walking, investigating, dust-bathing and preening than those indoor only. However, farming system was not found to significantly affect their feeding, drinking and fighting activities (p>0.05). The value of FA of tibia length of the broilers with outdoor access was significantly lower than that of the indoor-housed birds ($1.57{\pm}1.30$ vs $2.76{\pm}1.40$, p<0.05), while no difference was found for the value of FA in tibia diameter and wing length (p>0.05). TI of the broilers with outdoor access was 165.5 that was significantly higher than that (147.2) of the indoor birds (p<0.05). However, death rate in the outdoor run groups was significantly higher than that of the indoor ones ($2.0{\pm}0.81$ vs $4.0{\pm}0.82$, p<0.05). Meat quality was not affected by the two farming systems. It can be concluded that the results of this study may suggest that the indoor housing with outdoor access provides enriched environment for broilers and facilitates the expression of natural behaviors of the broilers but resulted in poorer performance and higher death rate.

Improvement of Indoor Air Quality by Coating of Indoor Materials of $TiO_2$ Photocatalyst Sol (이산화티탄 광촉매 졸(sol)의 실내환경 코팅에 의한 실내공기질 개선)

  • 양원호;김대원;정문호;양진섭;박기선
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.92-97
    • /
    • 2004
  • Three methods for VOCs emissions control in indoor air are reduction at the source, ventilation between indoor and outdoor, and removal. The best alternative should be to replace highly emitting sources with sources having low emissions, but the pertinent information on VOCs is not always available from manufactures. Other ways of improving indoor air quality are needed. It is to increase the outside fresh-air flow to dilute the pollutants, but this method would generally provide only a dilution effect without destruction in residence. An ideal alternative to existing technologies would be a chemical oxidation process able to treat large volumes of slightly contaminated air at normal temperature without additional oxidant such as ozone generator and ion generator. Photocatalytic oxidation(PCO) represents such a process. It is characterized by a surface reaction assisted by light radiation inducing the formation of superoxide, hydroperoxide anions, or hydroxyl radicals, which are powerful oxidants. In comparison with other VOCs removal methods, PCO offers several advantages. The purpose of this study was to explore the possibilities for photocatalytic purification of slightly contaminated indoor air by using visible light such as flurescent visible light(FVL). In this study, a PCO of relatively concentrated benzene using common FVL lamps was investigated as batch type and total volatile organic compounds(TVOCs) using a common FVL lamp and penetrated sun light over window. The results of this study shown the possibility of TiO$_2$ photocatalyst application in the area of indoor air quality control.

Development of IoT based Real-Time Complex Sensor Board for Managing Air Quality in Buildings

  • Park, Taejoon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.75-82
    • /
    • 2018
  • Efforts to reduce damages from micro dust and harmful gases in life have been led by national or local governments, and information on air quality has been provided along with real-time weather forecast through TV and internet. It is not enough to provide information on the individual indoor space consumed. So in this paper, we propose a IoT-based Real-Time Air Quality Sensing Board Corresponding Fine Particle for Air Quality Management in Buildings. Proposed board is easy to install and can be placed in the right place. In the proposed board, the air quality (level of pollution level) in the indoor space (inside the building) is easy and it is possible to recognize the changed indoor air pollution situation and provide countermeasures. According to the advantages of proposed system, it is possible to provide useful information by linking information about the overall indoor space where at least one representative point is located. In this paper, we compare the performance of the proposed board with the existing air quality measurement equipment.

Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station (서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가)

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Jangwon;Jo, Kyung-Ho;Jung, Eulgyu;Kim, Inkyu;An, Yeonsun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.233-244
    • /
    • 2014
  • The objective of this study was to explore the characteristics of concentration of indoor air pollutants, such as $PM_{10}$, $CO_2$, and $NO_2$, measured by tele-monitoring system in a Seoul Metropolitan underground railway station from January 1, 2008 to December 31, 2012. The annual average concentration of indoor air pollutants actually varied over a wide range and was found to exhibit marked variation with time and measurement sites (tunnel inlet, platform, and concourse). After installing platform screen doors, the average $PM_{10}$ concentration on platform and concourse was decreased by 43.8% and 31.2%, respectively during the study periods. The relationship between the concentration of $PM_{10}$ and meteorological parameters (relative humidity and rainfall) or the Asian dust events was regarded as statistically significant. The correlations between the number of boarding/alighting passengers and $PM_{10}$, $CO_2$, and $NO_2$ were calculated. A p-value of less than 0.01 was regarded as significant except $NO_2$. The I/O ratio of $PM_{10}$ concentration was elevated after a congested time (about 08:00 am). The average I/O ratios of $NO_2$ were observed in concourse and platform on 03:00 am with $1.76{\pm}0.91$ and $1.50{\pm}0.51$, respectively. The average daily variation of standard excess rate of $PM_{10}$ and $NO_2$ concentration in concourse and platform was investigated. The highest standard excess rate was observed on 21:00 (09:00 pm).

A Study on $PM_{10}$, $CO_2$ Concentrations in Child Daycare Centers and Teachers' Awareness of Indoor Air Quality (보육시설의 $PM_{10}$, $CO_2$ 농도와 보육교사의 실내 공기질 인식에 관한 연구)

  • Lee, Ji-Eun;Choi, Byung-Sun
    • Journal of the Korean Society of School Health
    • /
    • v.23 no.1
    • /
    • pp.29-40
    • /
    • 2010
  • Purpose: The purposes of this study were: (a) to assess indoor air quality such as $PM_{10}$, $CO_2$ concentrations in child daycare centers, (b) to compare the levels with each standard, and (c) to identify teachers' awareness of indoor air quality in child care centers. Methods: Data were obtained from seventeen child daycare centers and ninety-eight teachers in a district of Seoul, from April 3 to May 12, 2009. Collected data were analyzed by SAS 8.2, and descriptive statistics, $x^2$ test, student t-test, Pearson correlation analysis, and Spearman rank correlation were used. Results: The mean of $PM_{10}$ and $CO_2$ level were $50.3{\mu}g/m^3$ and 792.1ppm. Sixteen child daycare centers (94.2%) met the guidelines of the $PM_{10}$ level, so did thirteen child daycare centers (76.5%) in the $CO_2$ level. $CO_2$ levels were significantly low in child daycare centers using air cleaners than those do not using them (t=-6.03, p<.001). Types of child daycare centers were significantly correlated to the levels of $CO_2$, which public child daycare centers were low in $CO_2$ levels than those of private child daycare centers (t=-2.54, p=.013). There was no significant correlation between teachers' awareness and management attitude of indoor air quality while teachers' awareness of indoor air quality significantly raised the frequency of carpet cleaning. Methods of cleaning routines were significantly correlated with $PM_{10}$, and $CO_2$ levels. Conclusion: The $PM_{10}$ and $CO_2$ concentrations in child daycare centers were satisfactory. Those conditions are affected by general characteristics of child daycare centers and teachers' attitude regarding management of indoor air quality.

Development of Real-time Monitoring Platform for Indoor Air Quality Using Air Quality Sensors (AQ센서를 활용한 실내 대기 질 실시간 모니터링 플랫폼 개발)

  • Oh, Sang-Heon;Kim, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.206-209
    • /
    • 2018
  • According to data released by the WHO(World Health Organization), the death toll from indoor air pollution in 2016 was about 3.8 million. While many people are aware of outdoor air pollution, indoor air pollution is getting less attention. Recently, however, indoor air pollution has also become a big problem, raising many issues. Frequent indoor activities such as cooking and heating produce various pollutants, which can cause children and elderly with weak immune systems to be exposed to pollutants, which can cause serious health problems such as poor lung function and respiratory diseases. Therefore, in this paper, the IoT(Internet of Things) platform that measures and monitors indoor air quality using AQ(Air Quality) sensors is developed so that data can be monitored in real time through applications and reactive web.

  • PDF

Indoor Air Quality Monitoring Systems in the IoT Environment (IoT 기반 실내 공기질 모니터링 시스템)

  • Oh, Chang-Se;Seo, Min-Seok;Lee, Jung-Hyuck;Kim, Sang-Hyun;Kim, Young-Don;Park, Hyun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.5
    • /
    • pp.886-891
    • /
    • 2015
  • Recently, The World Health Organization announced that harms human health because of air pollution that are emerging as threats to human health worldwide. according to the, Seoul, 2011 According to a July 2014 - Public Facilities indoor air quality measurements, were examined to be in violation of indoor air pollution standards in most multi-use facility. Indoor air pollution resulting from this is present in the paper, and cause disease, such as pulmonary disease, asthma, bronchitis and to In this connection, the measurement of indoor air quality by using the environment sensor, analyzing the measured data to generate an actuator signal required for ventilation and improve indoor air quality by implementing a monitoring system with real-time measurement, autonomously managing the air quality in our lives so that it can be.

Characteristics for VOCs and aldehydes emission rates from architectural flooring (건축용 바닥재로부터의 VOCs와 Aldehydes 방출 특성)

  • Jang, Seong-Ki;Kim, Mi-Hyun;Seo, Soo-Yun;Lee, Woo-Suk;Lim, Jun-Ho;Lim, Jeong-Yun
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.544-552
    • /
    • 2006
  • Emission tests were carried out to investigate the characteristics of concentration according to flooring sort using small chamber method. The target Volatile Organic Compounds (VOC) included 27 individual compounds of environmental concern, which were determined by adsorption sampling and thermal desorption coupled with GC/MS method and by DNPH cartridge/HPLC method. The emission factor of Total Volatile Organic Compounds (TVOC) and Formaldehyde (HCHO) was detected $0.3mg/m^2{\cdot}h$ and $0.2mg/m^2{\cdot}h$ respectively, and the floorings of 37 (9 PVC Tile, 10 PVC Sheet, 18 Flooring) were satisfied emission standard. TVOC emission factor appeared in order of concentration of PVC Sheet, PVC Tile, and floor flooring, while HCHO was detected very high emission factor (as $0.4mg/m^2{\cdot}h$) at floor flooring above PVC series (as $0.001mg/m^2{\cdot}h$).