• 제목/요약/키워드: Indoor pollutants

검색결과 327건 처리시간 0.027초

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at kwangju Area

  • Son Bu-Soon;Song Mi-Ra;Yang Won-Ho;Park Jong-An
    • 한국환경과학회지
    • /
    • 제15권2호
    • /
    • pp.101-106
    • /
    • 2006
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals that are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCs and particulate matter $(PM_{10})$ during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and $PM_{10}$ were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. The measured mean concentrations of respiratory particulates were $30.5ng/m^3$ in indoor, $30.5ng/m^3$ in outdoor and $44.0ng/m^3$ on personal levels. The personal concentration was found higher than indoor and outdoor concentrations. The heavy metals mean concentrations were shown as indoor (Na>Zn>Cr), outdoor (Cr>Zn>Pb), and personal (Na>Cr>Zn) levels. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor and outdoor sources. Therefore, proper management should be taken to improve the indoor air quality in beauty shops.

Indoor Air Quality of Acidic Air Pollutants at a Private House in Seoul During the Spring Months

  • Lee, Hak-Sung;Kang, Byung-Wook;Kang, Choong-Min;Yeo, Hyun-Gu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권E3호
    • /
    • pp.109-115
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality at a private house in Seoul during the spring period. All indoor and outdoor samples were measured simultaneously using an annular denuder system. The data set was collected on twelve different days with a 24-hr sampling period in April and May 1997. The chemical species measured were HN $O_3$, HN $O_2$, S $O_2$ and N $H_3$in the gas phase and P $M_{2.5}$ (dp 2.5 ${\mu}{\textrm}{m}$), S $O_4$$^{2-}$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ in the particulate phase. Indoor concentrations of HN $O_2$, N $H_3$, and P $M_{2.5}$ were greater than outdoor levels. However, indoor concentrations of HN $O_3$, S $O_2$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ were less than those found from outdoors. In the case of S $O_4$$^{2-}$, the indoor and outdoor concentrations were similar. Indoor concentrations of P $M_{2.5}$ , S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ were dependent upon the outdoor concentrations. A tracer-gas decay technique with sulfur hexafluoride (S $F_{6}$ ) as the tracer gas was used to estimate the air exchange rate of a private home in the spring. The average air exchange rate was computed to be 2.87 h $r^{-1}$ .X> .

  • PDF

Bake Out에 의한 실내오염물질 저감에 관한 연구 (A Study on the Reducing Ratio of VOCs and Formaldehyde by Bake Out)

  • 조현;박용승;유복희;홍천화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2004년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2004
  • The purpose of this study is to evaluate the reduction effect of bake out on the concentration of indoor air pollutants by measuring the concentration of indoor pollutants(VOCs, HCHO) after the bake out. As a result of the study, bake out was considerably effective in reducing the concentration o( indoor air pollutants, showing relatively high reduction ratio around 40${\sim}$56%. However, continuous attention and control after the bake out is required for the prevention of the rise of the concentration by subsequent emission.

  • PDF

안트라사이트와 버미큘라이트를 혼입한 산화마그네슘 경화체의 흡착특성 (Adsorption properties of magnesium oxide matrix using anthracite and vermiculite)

  • 김대연;편수정;이동훈;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.224-225
    • /
    • 2018
  • Modern people are more interested in the indoor environment as they spend more time indoors than in the past. Among the air pollutants in the indoor air, ladon gas is a colorless, tasteless, odorless, inert gas produced by nuclear decomposition of naturally occurring uranium in rocks and soils. It has been proven that ladon gas is introduced into the room through cracks on the floor of the building or basement wall, and it causes various diseases such as lung cancer when exposed to radon during human breathing. The US Environmental Protection Agency (EPA) specifies 4pCi / L as a necessary measure for radon, and the Korea Environmental Protection Agency has implemented comprehensive indoor radon management measures since 2007. Therefore, in this study, we intend to adsorb and reduce radon in indoor air pollutants.

  • PDF

여름철 가정집에서의 산성오염물질에 대한 실내 공기질 특성 (Characteristics of Indoor Air Quality of Acidic Air Pollutants in a Private Home During Home During the Summer Season)

  • 이학성;강병욱;강충민;여현구
    • 한국대기환경학회지
    • /
    • 제17권2호
    • /
    • pp.193-201
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality in a residential area in the summer. All indoor and outdoor samples were measured simultaneously using an annular denuder system(ADS) in Seoul. The data set was collected from July 26 to September 11, 1997. The mean indoor/outdoor ratios measured from this study were : 0.34 for $HNO_3$; 0.91 for $HNO_2$; 0.22 for $SO_2$; 1.34 for $NH_3$; 0.78 for $PM_{2.5}(d_p$ <2.5 $mutextrm{m}$); 0.90 for $SO_{4}^{2-}$; 0.68 for $NO_{3}^{-}$ and 0.79 for $NH_{4}^{+}$. Indoor concentrations of $HNO_3$, $SO_2$ and $PM_{2.5}$ were highly correlated with the outdoor concentrations. The relationship between indoor and outdoor air is dependent, to a large extent, on the rate of air exchange between these two environments. A tracer-gas decay technique with sulfur hexafluoride ($SF_{6}$) as a tracer gas was used to estimate the air exchange of a private home in the summer. The average air exchange rate was estimated to be 23.7 hr(sup)-1. The deposition velocities for $SO_{4}^{2-}$, $NO_{3}^{-}$ and $NH_{4}^{+}$ calculated were 0.17, 0.69 abd 0.39 cm/sec, respectively.

  • PDF

환경 문제의 우선 순위 도출을 위한 비교 위해도 분석에 관한 연구 (Comparative Risk Analysis for Priority Ranking of Environmental Problems)

  • 김예신;임영욱;남정모;장재연;이동수;신동천
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권4호
    • /
    • pp.285-298
    • /
    • 2002
  • In Korea, no CRA (comparative risk analysis) studies have been undertaken, nor have their methodologies of such studies been established. Therefore, the objectives of this study were to establish the framework of CRA consisting of health risk, economic risk and perceived risk, and to estimate and compare these risks among the three environmental problems of air pollution, indoor air pollution and drinking water contamination, which are themselves subject to the eight sub -problems of hazardous air pollutants (HAPs), regulated pollutants (representative as PM 10) and dioxins (PCDDs/PCDFs) in air pollution, indoor air pollutants (IAPs) and radon in indoor air pollution, and drinking water pollutants (DWPs), disinfection by -products (DBPs) and radionuclides in drinking water contamination in Seoul, Korea. After which, the priorities of these problems were set by individual and integrated risk. From the results, the rankings of both health risk and economical risk were in the following order: radon, PM10, IAPs, HAPs, DWPs, dioxins, DBPs, and radionuclides among the eight sub problems. On the contrary, the ranking of perceived risk was in the following order: HAPs, dioxins, radionuclides, PM10, DWPs, IAPs, Radon and then DBPs among the eight sub-problems.

Comparative risk analysis for priority ranking of environmental problems in Seoul

  • Kim, Ye-Shin;Lee, Yong-Jin;Park, Hoa-Sung;Lim, Young-Wook;Shin, Dong-Chun
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 추계국제학술대회
    • /
    • pp.169-169
    • /
    • 2003
  • In Korea, there is no CRA studies and has not well known CRA and not well established their methodologies. Therefore, objectives of this study is to establish the framework of CRA consisting of health risk, economic risk and perceived risk and the detail methodologies of three main component of estimating and comparing those risks for on the three environmental problems of air pollution, indoor air pollution and drinking water contamination which being subjective to the eight sub-problems of hazardous ai. pollutants (HAPs), regulated pollutants (representative as PM10) and Dioxins (PCDDS/ PCDFs) in air pollution, and indoor ai. pollutants (IAPs) and Radon in indoor air pollution, and drinking water pollutants (DWPs), disinfection-by- products(DBPs) and radionuclides in drinking water contamination in Seoul, Korea. And then, their problems set priorities by individual and integrated risk. As a results, ranking of health risk were the following order of indoor air pollution, air pollution and then drinking water contamination, in three environmental problems and of radon, PM10, IAPs, HAPs, DWPs, Dioxins, DBPs, and then radionuclides in eight sub-problems. And that of economic risk were the same order. In the contrary, ranking of perceived risk were the following order of air pollution, drinking water contamination, and then indoor air pollution, and of HAPs, Dioxins, radionuclides, PM10, DWPs, IAPs, Radon and then DBPs.

  • PDF

Indoor exposure to hazardous air pollutants and volatile organic compounds in low-income houses in Lagos, Nigeria

  • Luqmon, Azeez;Musa, Olaogun;Mariam, Adeoye;Abdulazeez, Lawal;Babatunde, Agbaogun;Ibrahim, Abdulsalami;Adija, Majolagbe
    • Advances in environmental research
    • /
    • 제1권4호
    • /
    • pp.277-288
    • /
    • 2012
  • This study investigated exposure to air pollutants in rooms in low-income houses at Shomolu (R1), Mafoluku (R2) and Mushin (R3) in Lagos state. The concentrations of most measured exceeded limits of Illinois Department of Public Health (IDPH) for indoor air quality. Air quality index (AQI) in rooms studied was unhealthy for sensitive people in terms of CO, unhealthy in terms of $SO_2$ and very unhealthy in terms of $NO_2$ while moderate air quality was obtained in terms of $PM_{10}$ in most rooms. High concentrations of carbontetrachloride, formaldehyde and xylene measured could have been responsible for some of the health complaints of the occupants. Factor analysis shows that cooking with kerosene, use of gasoline generator and insecticide were the major contributors to indoor air pollution in these rooms. Therefore, there is need to urgently tackle poverty as all affected by these pollutants were poor who live in substandard houses without kitchens.

새집증후군 저감대책을 위한 실내 오염물질 확산 해석 코드 개발 (DEVELOPMENT OF A COMPUTER CODE FOR PREDICTION OF INDOOR POLLUTANT DISPERSION)

  • 전현준;양경수;최춘범
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.508-516
    • /
    • 2010
  • An efficient code has been developed to predict dispersion of indoor air pollutants The computing capability of the code has been compared with that of a commercial code inn a benchmark test. After that, the code has been employed to compute dispersion of a pollutant released from a new furniture, a kind of Sick Building Syndrome (SBS). A sofa which generates formaldehyde is implemented by using an immersed boundary method. Large Eddy Simulation (LES) is employed to obtain time-dependent velocity and scalar fields. LES has bee regarded as an academic tool, but the newly-developed code reveals a possibility of application of LES to practical problems, especially dispersion of indoor pollutants.

  • PDF

고속열차 객실의 휘발성유기화합물 및 부유미생물 분석 연구 (Study on the volatile organic compounds and suspended microorganism in a high-speed train passenger cabin)

  • 조영민;정우성;박덕신;권순박;박은영;정미영;목진용;이종범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1045-1050
    • /
    • 2008
  • The public interest on the indoor air quality of a high-speed train passenger cabin is drastically increasing due to the sealing of cabin. In this study, the concentration of volatile organic compounds and suspended microorganism in the high-speed train passenger cabin was investigated. There have been many studies on the indoor air quality of the high-speed passenger cabin, but the study on the indoor air quality without boarding of passengers were hardly carried out. As a result, it was very difficult to identify the exact source of air pollutants in the cabin. In this study, the indoor air quality of passenger cabin without any passengers was investigated so that the contribution of passengers as the source of various pollutants could be estimated.

  • PDF