• 제목/요약/키워드: Indoor materials

검색결과 603건 처리시간 0.026초

건설현장 내 작업자 실내측위를 위한 지구자기장 보정 범위 도출 (Identifying Correction Range of Geomagnetic Field for Indoor Positioning of Workers at Construction Site)

  • 김현민;안희재;이창수;김하림;고영웅;조훈희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.93-94
    • /
    • 2022
  • Although various studies about indoor positioning systems, such as beacon and Wifi, have been conducting for indoor positioning of workers at construction sites, these systems have limitations in terms of accuracy or economics. To overcome these limitations, geomagnetic field sequence-based indoor positioning technology can be a good alternative. However, it is necessary to correct the geomagnetic field near the construction material stocking area since the geomagnetic field can be distorted near construction materials such as rebars. Therefore, this study conducted an experiment for identifying correction range of geomagnetic field near the construction material stocking area. It was analyzed that the geomagnetic field should be corrected up to 60cm in the horizontal direction from the stocking point if the height of stocking area for rebars is 40cm or more. This study can be used for important reference for development of geomagnetic field sequence-based indoor positioning technology suitable for construction sites.

  • PDF

철도차량용 내장재의 휘발성유기화합물 방출특성 분석 (Characterization of Volatile Organic Compounds Emission from Interior Materials of Railway Passenger Cabin)

  • 조영민;박덕신;권순박;박은영
    • 한국철도학회논문집
    • /
    • 제11권2호
    • /
    • pp.182-187
    • /
    • 2008
  • 실내공기질의 중요성이 날로 부각되고 있다. 특히 휘발성유기화합물(VOCs)에 의한 실내공기의 오염은 매우 심각한 환경문제가 되고 있다. 이에 본 연구에서는 철도차량 객실용 시트커버와 바닥재를 대상으로 청정한 챔버 안에 넣고, 고정 환기 조건에서 VOCs 방출특성을 조사하였다. 챔버는 온도 $25{\pm}1^{\circ}C$, 상대습도 $50{\pm}5%$를 유지하면서 방출량을 조사하였다. 실험결과 바닥재가 시트커버보다 많이 양의 VOCs를 방출하는 것으로 나타났는데, 이는 바닥재가 PVC 재질이기 때문인 것으로 보인다. 방출량은 시간에 따라 점차 감소하였다.내장재에서 방출되는 VOCs는 객실 승객의 건강을 위협할 수 있으므로, VOCs를 덜 방출하는 내장재가 사용되어야 한다.

국내 라돈 취약가구에 대한 주거공간의 실내 라돈 농도에 관한 연구 (A Study on Indoor Radon Concentration among Vulnerable Households in Korea)

  • 주덕현;박기호;정희원;임형준;복동석;윤동원;민경환;문경덕;김정운;이지민;최원용;김성윤
    • 한국환경보건학회지
    • /
    • 제41권2호
    • /
    • pp.61-70
    • /
    • 2015
  • Objectives: The purpose of this research was to examine radon exposure in terms of the relationship between the living environment and indoor radon concentrations among vulnerable households. Methods: Nationwide, 1,129 subjects were selected using personal questionnaires for adequately understanding the living environment, installation of E-PERM radon gas detectors, and investigation of the structure of the housing. Results: The mean concentration of indoor radon for all subjects was $130.2Bq/m^3$ (GM=101.7), and a total of 438 subjects (38.8%) exceeded the recommended standards ($148Bq/m^3$) for public facilities by the Ministry of the Environment. By location, the highest concentrations ($164.3Bq/m^3$, GM=124.1) were seen in North Chungcheong Province. In the case of the Seoul/Gyeonggi Province metropolitan area, they showed $125.6Bq/m^3$ (GM=105.1) and $118.9Bq/m^3$ (GM=96.5), respectively. By type of housing, indoor radon concentrations in single-family housing were higher than in row/multi-family housing (p<0.01). Although indoor radon concentrations raised in accordance with year of construction (p<0.05), the difference between indoor radon concentrations in underground residences was not observed to be statistically significant (p=0.633). Conclusion: More studies are necessary in the future regarding the difference in indoor radon concentrations that may occur due to different of types of indoor construction, building materials, and the amount of building materials.

입주 전 신축 건물의 사무실내 방향족 탄화수소의 농도 특성 (Characteristics of Aromatic Hydrocarbons Measured in an As-built Building)

  • 나광삼;배귀남;김용표
    • 한국대기환경학회지
    • /
    • 제16권5호
    • /
    • pp.545-552
    • /
    • 2000
  • Eight aromatic hydrocarbons were quantified in a newly constructed building before occupancy during the period of November 1997 to January 1998. Air samples were collected in 6 L stainless steel canisters for 8 hours based on working hour. It was found that the measured total concentration of aromatic hydrocarbons decreases rapidly with time up to a steady-state value. However, the fractions for each aromatic hydrocarbon were greatly changed with time. The concentration ratios of indoor to outdoor for aromatic hydrocarbons are greater than 1 during early period of the measurement, and the ratios decrease with time. The concentrations of toluene, m+p-xylene, ethylbenzene, and o-xylene are much higher than those of styrene, 1, 2, 4-trimethylbenzene, and 1, 3, 5-f trimethylbenzene in indoor air. The concentration fractions of m+p-xylene, ethylbenzed, and o-xylene in indoor air are about twice as hight as those in outdoor air measured during the similar period. It was concluded that the aromatic hydrocarbons were emitted from building materials, paints, and adhesives in an-built building.

  • PDF

고속전철의 실내소음특성에 관한 연구현황분석 (State-of-the-Art on the Indoor-Noise Characteristics of High Speed Train)

  • 이우식;박철희
    • 한국철도학회논문집
    • /
    • 제2권3호
    • /
    • pp.18-25
    • /
    • 1999
  • A high speed train named Korean High Speed Train (KHST) with its maximum operating speed 350 km/h is now under development. For the successful design of a quiet and comfortable high speed train, it is important to understand the general features of the noise and vibration characteristics of high speed train. This paper reviews extensively collected materials on the noise and vibration characteristics of existing high speed trains. Based on the noise and vibration characteristics of TGV systems, a simple indoor-noise prediction rule is proposed for the TGV-type high speed trains such as KHST The indoor-noise of KHST at 350km/h is expected to be larger than at least 71 dBA. Some important researches conducted for designing KHST during last two years under the G-7 project are also briefly introduced at the last part of this paper.

  • PDF

외국식물의 배치변화에 따른 폼알데하이드와 VOCs 농도저감에 관한 연구 (A Study on the Reduction of Formaldehyde and VOCs by Positions of Foreign Plants)

  • 송정은;김용식;손장열
    • KIEAE Journal
    • /
    • 제8권2호
    • /
    • pp.53-58
    • /
    • 2008
  • With architectural technology, a building has been a far dense and close. So the thermal environment of the building has become pleasant, but the quality of indoor air has been degraded. Using synthetic products for construction materials and furniture indoors escalates the concentration of volatile organic compounds(VOCs) at indoor air, threatening the health of the residents. To reduce the concentration of volatile organic compounds at indoor air, many methods are designed, and of late, concern has been increased about the effect of air purification using air purifying plants. Field measurements were performed using Aglaonema brevispathum, Pachira aquatica and Ficus benjamiana, which were verified as air-purifying plants by NASA. The effect of reducing the concentration of air contaminants by plant studied in a full scale mock-up model. The variations of concentration of Benzene, Toluene, Ethylbenzene and Formaldehyde were monitored. In most cases, the effect was excellent in Toluene and formaldehyde in summer.

The Analysis of VOCs by GC/MS with Whole Column Coldtrapping on a Fused Silica Capillary Column in Indoor Environment

  • Dai, Shugui;Zhang, Lin;Bai, Zhipeng
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.829-834
    • /
    • 1995
  • Whole column coldtrapping(WCC) on a fused silica capillary (FSCC)combined with GC/MS analysis was evaluated for use in the investigation of volatile organic compounds(VOCs) in indoor air. Research had indicated that a temperature of $-80^{\circ}C$ is optimal for WCC. Samples were analyzed on a $50m{\times}0.2mm$ cross-linked 5% phenylmethylsilicone fused silica column. Liquid nitrogen was used as the coolant for the peak resolution significantly. The analysis can be performed quickly and conveniently. More than 112 of VOCs were determined in the samples from three typical indoor environment including: (1) a room which had just been decorated involving building materials and paints; (2)a kitchen used for Chinese cooking, and (3) a room had tobacco smoke. The method is could be readily applied to rapid sample screening for VOCs contamination surveys or initial investigations with its valid and simple sampling and analytical technique.

  • PDF

Simulated Study on Typical Sources of Volatile Organic Compounds (VOCs) in Indoor Air

  • Dai, Shugui;Bai, Zhipeng;Zhu, Tan;Zhang, Lin
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.745-751
    • /
    • 1995
  • In this paper, several simulated devices were constructed for determining components of organic vapors emitting from decorative materials, daily use chemicals and from common behavior of human beings, such as smoking and cooking. The VOCs were preconcentrated on activated carbon and then desorbed by carbon disulphide. The results were obtained by GC/MS analysis and computer searching. It can be concluded that the categories of the sources and the components of organic vapors in indoor air are very complicated, and different sources of VOCs in indoor air have their own emission characteristics.

  • PDF

실내 환경 요인이 치과위생사의 신체증상에 미치는 영향 (Effect of indoor environmental factors on the physical symptoms of dental hygienists)

  • 홍민희
    • 한국치위생학회지
    • /
    • 제14권2호
    • /
    • pp.197-204
    • /
    • 2014
  • Objectives : The purpose of the study is to examine the effect of the indoor environmental factors of dental hygienists on physical symptoms. Methods : The subjects were 210 dental hygienists in dental hospitals and clinics in Seoul, Gyeonggi Province, Incheon and South Chungnam Province from May 1 to June 20, 2013. Results : There were significant differences between the presence or absence of windows in respiratory symptoms and eye symptoms. Room temperature, bad smell, and dry humidity had significant influences on physical and respiratory symptoms. Dermatological and ophthalmological symptoms were affected by dryness, smell and dusts. Dusts and bad smell also had influences on a variety of subjective symptoms. Conclusions : The indoor environments of dental hospitals and clinics affect the respiratory, dermatological, and ophthalmological symptoms because various hazardous materials are generated by the dental treatment. Therefore dental hygienists should have a correct understanding of bacteria, dusts and bio-aerosol in order to ensure the successful environmental control.

안트라사이트 입도에 따른 시멘트 경화체의 공기량 및 유동성 특성 (Air Content and Fluidity Properties of Cement Matrix according to Anthracite Particle-size)

  • 경인수;편수정;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.92-93
    • /
    • 2017
  • Recently, there has been an increasing interest in natural radioactive gas radon(Rn-222), the problem of indoor air quality pollution to worldwide. It has been scientifically proven to be hazardous to various diseases such as lung cancer and skin cancer if the human body is exposed to long-term accumulation of atomic nuclei due to the destruction of radon and alpha lines. Based on the indoor air quality control policy, this study is a basic experiment in the manufacture of a selective elimination function to containing radon adsorption and reduction of radon concentration, which is used to absorb radioactive isotopes such as phosphorus and radon in indoor environment.

  • PDF