• Title/Summary/Keyword: Indoor light

Search Result 519, Processing Time 0.023 seconds

Analyzing Therapeutic Design Characteristics in the Indoor Atrium of the Outpatient Areas in Children's Hospitals Overseas (해외 어린이병원 외래진료부의 실내 아트리움에 적용된 치유적 계획특성 분석)

  • Seo, Jae-Yeon;Cho, Min-Jung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.9
    • /
    • pp.65-75
    • /
    • 2019
  • This study aims at analyzing the therapeutic design characteristics implemented in the indoor atriums of the outpatient areas in four children's hospitals in London and San Francisco. A mixed-method approach was used to examine the spatial configurations and design elements in the atriums, while a literature review was conducted to understand the therapeutic design characteristics relevant to atrium spaces and children's healthcare facilities. The spatial design and the pattern of use of the atrium in each hospital were studied during field visits and interviews with the hospital management staff. Based on the literature review and the observations from the field study, a Visibility Graphic Analysis was chosen to examine the visibility, accessibility, and intelligibility of the spatial configurations in the atriums of each hospital. In addition, the openness, restfulness, and vibrant ambience of the design elements in the atriums of each hospital were investigated by surveying fifty-two design professionals on the quality of the design elements in the atriums. A spatial configuration analysis, confirmed that all the atrium spaces had high visibility, accessibility, and intelligibility due to their high connectivity, integration, intelligibility, and because the atriums were laid out in the open lobby space, along the major circulation axis, or in the circulation intersection. In the survey of the design element evaluation, all atriums proved to be appropriate in terms of openness, while the adequacy of restfulness and vibrant ambience differed depending on the hospitals. Notably, location and orientation, access, natural light, outdoor view, and play facilities were found significant environmental design elements determining the successful implementation of the therapeutic design in the atriums. The observations from the aforementioned are further discussed to enhance the therapeutic design quality of atrium spaces in children's hospitals.

Evaluation of Mobile Device Based Indoor Navigation System by Using Ground Truth Information from Terrestrial LiDAR

  • Wang, Ying Hsuan;Lee, Ji Sang;Kim, Sang Kyun;Sohn, Hong-Gyoo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.5
    • /
    • pp.395-401
    • /
    • 2018
  • Recently, most of mobile devices are equipped with GNSS (Global Navigation Satellite System). When the GNSS signal is available, it is easy to obtain position information. However, GNSS is not suitable solution for indoor localization, since the signals are normally not reachable inside buildings. A wide varieties of technology have been developed as a solution for indoor localization such as Wi-Fi, beacons, and inertial sensor. With the increased sensor combinations in mobile devices, mobile devices also became feasible to provide a solution, which based on PDR (Pedestrian Dead Reckoning) method. In this study, we utilized the combination of three sensors equipped in mobile devices including accelerometer, digital compass, and gyroscope and applied three representative PDR methods. The proposed methods are done in three stages; step detection, step length estimation, and heading determination and the final indoor localization result was evaluated with terrestrial LiDAR (Light Detection And Ranging) data obtained in the same test site. By using terrestrial LiDAR data as reference ground truth for PDR in two differently designed experiments, the inaccuracy of PDR methods that could not be found by existing evaluation method could be revealed. The firstexperiment included extreme direction change and combined with similar pace size. Second experiment included smooth direction change and irregular step length. In using existing evaluation method which only checks traveled distance, The results of two experiments showed the mean percentage error of traveled distance estimation resulted from three different algorithms ranging from 0.028 % to 2.825% in the first experiment and 0.035% to 2.282% in second experiment, which makes it to be seen accurately estimated. However, by using the evaluation method utilizing terrestrial LiDAR data, the performance of PDR methods emerged to be inaccurate. In the firstexperiment, the RMSEs (Root Mean Square Errors) of x direction and y direction were 0.48 m and 0.41 m with combination of the best available algorithm. However, the RMSEs of x direction and y direction were 1.29 m and 3.13 m in the second experiment. The new evaluation result reveals that the PDR methods were not effective enough to find out exact pedestrian position information opposed to the result from existing evaluation method.

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color (분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.44-52
    • /
    • 2017
  • This paper is based on a study of the response characteristics of photoelectric type smoke detector chambers according to dust color. Due to an amendment to the Fire Safety Codes to automatic fire alarm systems and visual alarm device, the installation of indoor smoke detectors has become mandatory, but in Korea there is still insufficient research on the non-operation or false alarms that could arise in indoor environments by indoor dust and other environmental conditions etc. In light of this, for this study, research was conducted on the indoor adaptability of smoke detector under various colors of fiber dust that were judged to occur most frequently in among the common indoor dust, photoelectric smoke detector with the lattice-type smoke detection chamber that the smoke detector which is most popular in the country was used, and four colors of fiber dust (brown, white, gray and black) were used the test dusts for carrying out dust and sensitivity testing. Also, the voltage of the photocell part of the smoke chamber was measured, and the scattering phenomenon in the chamber was observed. The result of the testing showed that all four dust types were suitable for dust and sensitivity testing under conditions of pollution A. Yet, there were occasions, at pollution B or C, where the brown, white and gray dust would cause fail alarm during operation testing. And black dust was confirmed to cause non-operation during operation testing. In the case of brown and white dust, the voltage measurement result of the photocell part of the smoke chamber confirmed that the voltage increases as the pollution level increases, and in the case of gray and black dust, the voltage decreases.

A Indoor Management System using Raspberry Pi (라즈베리 파이를 이용한 실내관리 시스템)

  • Jeong, Soo;Lee, Jong Jin;Jung, Won Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.745-752
    • /
    • 2016
  • In the era of the Internet of Things, where all physical objects are connected to the Internet, we suggest a remote control system using a Raspberry Pi single-board computer with ZigBee, which can turn an indoor light-emitting diode (LED) and a multiple-tap on and off, and with a smart phone can control the brightness of the LED as well as an electronic door lock. By connecting an infrared (IR) transmitter module to the Raspberry Pi, we can control home appliances, such as an air conditioner, and we can also monitor indoor images, indoor temperatures, and illumination by using a smart phone app. We developed a method of finding out IR transmission codes required for remote-controllable appliances with an AVR micro-controller. We suggest a method to remotely open and shut an office door by novating the door lock. The brightness level of an LED (between 0 and 10) can be controlled through a PWM signal generated by an ATmega88 microcontroller. A mutiple-tap is controlled using an ATmega32, a photo-coupler, and a TRIAC. The signals for measured temperature and illumination are converted from analog to digital by using the ATtiny44A microcontroller transmitting to a Raspberry Pi through SPI communication. Then, we connect a camera to the CSI head of the Raspberry Pi. We can turn on the smart multiple-tap for a certain period of time, or we can schedule the multi-tap to turn on at a specific time. To reduce standby power, people usually pull out a power code from multiple-taps or turn off a switch. Our method helps people do the same thing with a smart phone, if they are away from home.

The effects of LEDs and duty ratio on the growth and physiological responses of Silene capitata Kom., endangered plant, in a plant factory

  • Park, Jae-Hoon;Lee, Eung-Pill;Han, Young-Sub;Lee, Soo-In;Cho, Kyu-Tae;Hong, Yong-Sik;You, Young-Han
    • Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.174-182
    • /
    • 2018
  • Background: In this study, we observed their growth and physiological responses using a variety of duty ratio under the mixed light using red, blue, and white lights. The red+blue mixed light was treated with 95%, 90%, 85%, 80%, and 75% duty ratios and red+blue+white mixed light with 85% and 70% duty ratios. We examined the width and length of leaves, total number of leaves, and number of shoots to examine their growth responses. The physiological responses were studied by measuring their photosynthetic rate, transpiration rate, stomatal conductance, water use efficiency, chlorophyll content, and fluorescence ($F_o$, $F_m$, and $F_v/F_m$). Results: We found that lower duty ratio caused the length and width of the leaves to grow longer under red+blue mixed light but that it did not cause any difference in the red+blue+white mixed light condition. In addition, there was no difference in the number of leaves and shoots among all treatments. In the red+blue mixed light condition, the photosynthetic rate was no difference, but both transpiration rate and stomatal conductance were the highest at 95% duty ratio than in other ratios. Water use efficiency pattern was similar to that of photosynthetic rate; water use efficiency was no difference. Chlorophyll content was the highest at 95% duty ratios, and it was the least at 90%, 85%, and 75% duty ratio. $F_o$ and $F_m$ values were relatively high at 85% and 80% duty ratio and low at 90% duty ratio while $F_v/F_m$ showed no difference. Conclusions: Under the red+blue+white mixed light, all physiological items showed no difference between 70 and 85% treatments. But, photosynthetic rate, water use efficiency, chlorophyll content, and $F_v/F_m$ were relatively greater in the red+blue+white mixed light than in the red+blue mixed light. Therefore, red+blue+white mixed light treated with 70% duty ratio could lessen the environmental stress and save more power when cultivating Silene capitata in a plant factory.

Effect of Light Intensity on the Growth Responses of Three Woody Plants for Indoor Landscaping (실내녹화용 목본식물 3종의 초기 생육반응에 미치는 광량의 영향)

  • Kwon, Kei-Jung;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • The purpose of this study was to investigate the effects of light intensity on the initial growth response of three woody plants for indoor landscaping; Ardisia pusilla, Clusia rosea and Fatsia japonica. The plants were planted in 10cm pots, the light intensities used were of four levels-15, 30, 60, $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD-and light irradiation time was set to 12/12 (day/night). Growth responses including plant height, leaf length, leaf width, chlorophyll fluorescence (Fv/Fm), SPAD and Hunter values were measured at 4-week intervals, and shoot weight and root weight of fresh and dry plants were measured after completion of the experiment. Fatsia japonica tended to show greater leaf length and leaf width as light intensity became greater, while other plants did not show any significant differences at different light intensities. The Fv/Fm value of the Ardisia pusilla was found to be stressed at 60 and $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, while the Fv/Fm values were within normal range with other plants or at other light intensity levels to show no stress. Only Clusia rosea showed significantly different SPAD values at $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and there was no significant SPAD value difference found with other plants or at other light intensity levels. While Hunter values of the Ardisia pusilla did not show any significant differences at any light intensity levels, Clusia rosea and Fatsia japonica showed specificity in L, a and b values at 60 and $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. Ardisia pusilla showed a big stem growth at $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and Clusia rosea showed a steady growth at 60 and $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

Photoinduced Hydrophilicity of Heterogeneous TiO2/WO3 Double Layer Films (이종 접합 구조를 갖는 TiO2/WO3 이중 박막의 광유기 친수 특성)

  • Oh, Ji-Yong;Lee, Byung-Roh;Kim, Hwa-Min;Lee, Chang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.11
    • /
    • pp.715-720
    • /
    • 2015
  • The photoinduced hydrophilicity of $TiO_2/WO_3$ double layer films was fabricated by using a conventional rf-magnetron sputtering method. The photoinduced hydrophilic reaction of the $TiO_2$ surface was enhanced by the presence of $WO_3$ under the $TiO_2$ layer by irradiation of a 10 W cylindrical fluorescent light bulb. However, when the $TiO_2$ and $WO_3$ layers were separated by an insulating layer, the surface did not appeared high hydrophilic, under the same light bulb. The enhanced photoinduced hydrophilic reaction can be explained by the charge transfer between $TiO_2$ and $WO_3$ layers. It was also demonstrated that visible light passing through the $TiO_2$ layer could excite $WO_3$. Thus, visible light can be used for the hydrophilic reaction in the present $TiO_2/WO_3$ system.

Technology Trends and Technology Development of Marin Lantern (점멸식 해상용 등명기 기술개발 동향 및 개발 사례)

  • Yang, Hyun-Kyoung
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2017.11a
    • /
    • pp.220-221
    • /
    • 2017
  • The initial light emitting diode (LED) has been used as a display device for various mechanical devices due to its low power. The development of LED technology has made it possible to express color with high power and high brightness. Therefore, it is used as a display such as a traffic signal, a large electric signboard, and an automobile display, and is also adapted as an indoor or outdoor light source such as an incandescent or a fluorescent lamp which requires the high luminance. The bulb of marine lantern, which is used for the aids to navigation, was replaced to LED. The first marine LED lantern was manufactured using multiple LEDs. However, if the optical design is renewed by the development of LED or even if a few LEDs are used, it is possible to satisfy the brightness and the light distribution required by the marine LED lantern.

  • PDF

Performance comparison of MIMO-VLC systems according to the change of an emission angle (발광 각도 변화에 따른 MIMO-VLC 시스템의 성능 비교)

  • Lee, Byung-Jin;Kim, Yong-Won;Kim, Young-Keun;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.73-79
    • /
    • 2014
  • Visible light communication is a communication method using an LED having a high-speed ON / OFF rate data to be transmitted, it is used as a wireless high speed data transmission. VLC system evolves, the problem of basic research is intended to improve performance and ensure reliability of the communication. The nature of the visible light communication, communication is performed only in the reach of the light, which indicates a big difference by the emission angle of the light. Therefore, in this paper, in the case of indoor environments generally, with the attributes of the multiple LED is equipped, was applied to a MIMO (Multiple Input Multiple Output) communication system. and analyzed SNR performance and total power can be obtained on the reception side by changing the emission angle of the transmitter. As a result of the simulation was run against this, it was confirmed that there is a significant impact on the performance of BER and SNR performance by the emission angle of the transmitter.