• Title/Summary/Keyword: Indoor facility

Search Result 227, Processing Time 0.021 seconds

Effects of Service Quality of the Indoor Golf Practice Facility on Customer Satisfaction, Customer Loyalty and Intention to Repurchase : Verification of Mediating Effect on Customer Satisfaction and Customer Loyalty (실내골프연습장의 서비스품질이 고객만족, 고객충성도 및 재등록의사에 미치는 영향 : 고객만족과 고객충성도의 매개효과 검증)

  • Lee, Sheng Yen;Park, Kyoung Shil;Cong, Rui
    • Journal of Digital Convergence
    • /
    • v.16 no.10
    • /
    • pp.497-510
    • /
    • 2018
  • This study aims to establish effects of service quality of the indoor golf practice facility on customer satisfaction, customer loyalty and intention to repurchase. Consumers using indoor golf practice facility were selected as the target population of this study, and 238 individuals were extracted by convenience sampling and administered a survey. The results are as follows. First, facility, process, instructor positively influence customer satisfaction. Second, facility, instructor positively influence customer loyalty. Third, facility, process, instructor positively influence intention to repurchase. Fourth, customer satisfaction positively influence intention to repurchase. Fifth, customer loyalty positively influence intention to repurchase. Sixth, customer satisfaction mediated service quality of indoor golf practice facility and intention to repurchase. Finally, customer loyalty partly mediated service quality of indoor golf practice facility and intention to repurchase.

Evaluation of Pollutants Emissions according to the Selling Store in Department Store (백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가)

  • Wang, HyeongSeok;Hwang, JunSeok;Chang, SeongJin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.1
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).

A study on the Measurement and Improving Method of Indoor Air Quality in a Educational Facility (교육시설물의 실내공기질 측정 및 개선방안에 관한 연구)

  • Kim, Sung-Kyum;Kim, Jae-On;Cho, Chang-Yeon;Kim, Jong-Rok;Son, Jae-Ho
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.4
    • /
    • pp.43-52
    • /
    • 2007
  • People spend more than 90% of their time indoor. Nowadays as they are interested in environment much more than before, indoor air pollution has been regarded as new environmental problems. At present, an air quality check is required prior to the completion of construction. However this study shows that the density level of HCHO and VOCs in a classroom was increased after furnishing the classroom. Thus, to measure the quality of air more effectively and accurately, it should be measured after the indoor space are furnished. Newly-built schools are tested for this study. The building sites were investigated to measure and evaluate the IAQ (Indoor Air Quality) in newly-built schools. The result of this study can be used as a basis to improve the environment air condition of the educational facilities.

A study on the concentration distribution of CO and $CO_2$ by a form of parking lot in the multiplex use facility (다중이용시설의 주차장 형태에 따른 CO, $CO_2$ 의 농도분포에 관한 연구)

  • Sin, Ji-Won;Kim, Tea-Woo;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.316-321
    • /
    • 2006
  • Multiplex use facility emphasized the importance of indoor air environment because many people using that place. People using parking lot of multiplex use facility in little time, but a pollutant of in indoor air menacing user health. This study measure and analyze the CO, $CO_2$ for better air quality of an indoor parking lot in the multiplex user facility. As a result, two-way opened above ground parking lot is higher numerical value of CO, $CO_2$ than an underground parking lot. And a parking lot of square form is higher numerical value of $CO_2$ than a parking lot of rectangle form.

  • PDF

A Study on the Development of an Indoor Level of Detail(LOD) Model for the Linkage between BIM and GIS: Focusing on the Indoor Facility Management (BIM과 GIS 연계를 위한 실내 세밀도 모형 개발에 관한 연구: 실내 시설물 관리 중심으로)

  • Kang, Hye Young;Hwang, Jung Rae;Hong, Chang Hee
    • Spatial Information Research
    • /
    • v.21 no.5
    • /
    • pp.73-82
    • /
    • 2013
  • In recent years, according to the increase of interests in indoor space, various researches are being carried out for the construction and services of indoor spatial information. BIM data is very useful to build indoor spatial information. Accordingly, many studies for the use of BIM data on GIS part are in progress. In order to take advantage of BIM data on GIS part, the conversion technology for building indoor data and visualization techniques are required. However, most of the previous researches are focused on the conversion technology to construct indoor spatial information by importing BIM data into GIS applications while there is few research on visualization. In this study, an indoor LOD(Level of Detail) model is proposed to apply to on indoor facility management system when indoor data was constructed based on BIM data for the linkage between BIM and GIS.

A Consideration of Accuracy Correction Methods in RTLS for Indoor Facility Management with Drones

  • Yeo, ChangJae;yu, Jungho
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.210-213
    • /
    • 2017
  • The construction industry has witnessed an exponential growth of drones used in the field over the past few years. Likewise, the field of maintenance has paid increasing attention to using drones with a view to improving the efficiency of condition checks in high-rise buildings and major space. Although operators manipulate drones to inspect buildings at present, drones are expected to autonomously move around without operators in a few years. Also, for indoor maintenance, it is important for drones to find accurate locations, which is implemented by real-time locating systems(RTLS). Yet, the accuracy of RTLS varies across the types of systems and indoor settings, which warrants a locating system suitable for indoor space and a location correction system designed to improve the accuracy. Hence, the current study investigated the accuracy of real-time locating systems(RTLS) for the maintenance of indoor space of buildings with drones and delved into the methods of correcting the location information to improve the accuracy of RTLS.

  • PDF

Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings (다중이용시설에서의 실내공기중 미생물 분포에 관한 연구)

  • Kim Yoon Shin;Lee Eun Gyu;Yup Moo Jong;Kim Key Young
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.85-92
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991 - February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001 - June 2001 in Seoul. Sites including book store, department store, theater, subway station, underground shopping center, hospital, office building, sports facility, and eduationa institutio were chosen to measure indoor microorganism. The results were as follows: 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. The highest concentration of 711cfu/m$^3$ was found in the subway station and the lowest concentration of 44cfu/m$^3$ was found in office building. 2. The average of staphylococci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. The highest concentration of 502cfu/m$^3$ was found in the subway station and the lowest concentration of 14cfu/m$^3$ was found in sports facility and educational institution. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites. The highest concentration of 252cfu/m$^3$ was found in the hospital and the lowest concentration of 32cfu/m$^3$ was found in office building. 4. Ratio of Indoor/Outdoor, determined by site was 1.12-2.38 in total count, 1.00-2.35 in staphylococci, and 0.99-1.34 in fungus. 5. The positive results of test were 12-24% in indoor and 9-43% in outdoor. 6. By gram staining gram positive cocci were 59.9%, gram positive bacill 24.4%, gram negative bacilli 10.4%, and gram negative cocci 0.5%.

A Study on the Planning of Indoor Environment Factors for Sustainable School Facility (지속가능한 학교시설을 위한 실내환경 계획 요소에 관한 연구)

  • Shin, Dong-Sik;Lee, Jong-Kuk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.10 no.1
    • /
    • pp.34-41
    • /
    • 2011
  • Global environment is getting deteriorated at an alarming rate. Eco-school could be one of the effective solutions to project our environment and a good sample of architecture to economize in total energies, resources and greenhouse gases. In case of our country, the study of eco-school planning is not sufficient compared with other countries, so this paper would be a good study on the indoor environment of the classroom by surveying their opinions and ideas from the group of users in school facility. The result of this study shows that the proper installation of building equipment and nature ventilation system is necessary to provide delightful environment for the students and to save the energy. To ensure that we have adequate saving and protection it is necessary to change the existing appraisal standard.

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) in Public Facilities, Korea

  • Kim, Ho-Hyun;Lim, Young-Wook;Jeon, Jun-Min;Kim, Tae-Hun;Lee, Geon-Woo;Lee, Woo-Seok;Lim, Jung-Yun;Shin, Dong-Chun;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.72-84
    • /
    • 2013
  • In the study, pollution levels of indoor polycyclic aromatic hydrocarbons (PAHs) in public facilities (vapor phase or particulate phase) were evaluated, and a health risk assessment (HRA) was carried out based on exposure scenarios. Public facilities in Korea covered by the law, including underground subway stations, funeral halls, child care facilities, internet cafes (PC-rooms), and exhibition facilities (6 locations for each type of facility, for a total of 48 locations), were investigated for indoor assessment. For the HRA, individual excess cancer risk (ECR) was estimated by applying main toxic equivalency factor (TEF) values suggested in previous studies. Among the eight public facilities, internet cafes showed the highest average $PM_{2.5}$ concentration at $110.0{\mu}g/m^3$ (range: $83.5-138.5{\mu}g/m^3$). When assuming a risk of facility exposure time based upon the results of the surveys for each public facility, the excess cancer risk using the benzo(a)pyrene indicator assessment method was estimated to be $10^{-7}-10^{-6}$ levels for each facility. Based on the risk associated with various TEF values, the excess cancer risk based upon the seven types cancer EPA (1993) and Malcolm & Dobson's (1994) assessment method was estimated to be $10^{-7}-10^{-5}$ for each facility. The excess cancer risk estimated from the TEF EPA (2010) assessment was the highest: $10^{-7}-10^{-4}$ for each facility. This is due to the 10-fold difference between the TEF of dibenzo(a,e)fluoranthene in 2010 and in 1994. The internet cafes where smoking was the clear pollutant showed the highest risk level of $10^{-4}$, which exceeded the World Health Organization's recommended risk of $1{\times}10^{-6}$. All facilities, with the exception of internet cafes, showed a $10^{-6}$ risk level. However, when the TEFs values of the US EPA (2010) were applied, the risk of most facilities in this study exceeded $1{\times}10^{-6}$.

Kids Color-design Playground Apparatus Proposal (아동 색채조형 놀이기구 디자인 제안)

  • Song, Ji Hong;Choi, Kyung Ran
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.4
    • /
    • pp.239-249
    • /
    • 2014
  • Color is an important subject of interest for cognitive developmental stages of children and it also correlate to emotional and physical development. Children can acquire concept of color by 'play'. Color play can be experienced to children through diversity activity and theses activities contain creative craft art activity. The color-paly with art activity for kids can be called 'kids color-design play'. Recently, indoor playgrounds are rapidly grow-up because parent's concern degree that about play activity get higher. The indoor playground being enlargement and it contains various paly contents. Color-design play is also enacted animatedly in kids indoor playground. The great part of color-design plays are enacted through program that needs teaching. On the other hand, color-design play facility that children can play spontaneously is not composed sufficiently. Therefore this study aim at design proposal of 'Kids color-design playground apparatus' in indoor playground.

  • PDF