• Title/Summary/Keyword: Indoor environment

Search Result 2,579, Processing Time 0.031 seconds

Adaptive Indoor Location Tracking System Based on IEEE 802.15.4a (IEEE 802.15.4a 기반의 환경 적응형 위치 추적 시스템에 관한 연구)

  • Jeon Hyeon-Sig;Woo Sung-Hyun;Cho Sang-Do;Na Jong-In;Kim Ki-Hwan;Park Hyun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.5A
    • /
    • pp.526-536
    • /
    • 2006
  • According as Ubiquitous comes, interest for indoor location tracking system was more increased socially. However, existing indoor location tracking system doesn't correspond actively in frequent change of indoor environment, and there is a problem that correct location measurement of transfer object is difficult by NLOS property of indoor environment. Purpose of this paper proposes environment accommodation location tracking system that is improved location precision of transfer object and grasps location of indoor transfer object effectively that is essential element effectively to provide service to satisfy various user's request according as Ubiquitous comes.

Sensitivity Analysis of Indoor Environment Factors along with Changes of Outdoor Air Condition (외기상태의 변화에 따른 실내 환경인자의 민감도 분석)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.2
    • /
    • pp.125-136
    • /
    • 2010
  • The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. A sensitivity analysis of indoor environment factors was carried out to grasp influences along with changes of atmospheric conditions. An integrated multizone model was used to predict these sensitivities. This model was applied to an apartment with six zones. Airflow rates are influenced very seriously by changes of wind direct or wind velocity, but are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air temperatures are influenced very directly by changes of outdoor air temperature, but are influenced very slightly by wind direction or wind velocity and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air humidities are influenced very directly by changes of outdoor air humidity, but are not influenced at all by changes of outdoor air contaminant concentration and have little or no influence by changes of wind direction, wind velocity, or outdoor air temperature. Indoor air contaminant concentrations are influenced very seriously by changes of wind direct or wind velocity, but are influenced somewhat by changes of outdoor air contaminant concentration and are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity.

Analysis of the Indoor Environmental Characteristics of Educational Facilities (Case Study of Thermal and Acoustical Environment of Elementary School by Field Measurement) (교육시설의 실내환경 특성 분석에 관한 연구 (초등학교의 열 및 음환경 실측조사에 의한 사례연구))

  • Cho, Min-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.59-65
    • /
    • 2007
  • This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.

Analysis of Thermo Environment Change by Introduction of Indoor Water Space (실내 수공간 도입에 따른 온열 환경 변화 분석)

  • Oh, Sang Mok;Oh, Se Gyu
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.53-60
    • /
    • 2012
  • This research is an illustrative research to verify the thermo environmental change created after introduction of indoor pond through abridged model test and simulation analysis. Especially, temperature and comfort level are analyzed by adjusting factors like size of water space, distance length, and location. Summary of the research is as follows. First, the most effective size of water space is 7% of the indoor size, from southern side. Temperature reduction effect is about $1.6^{\circ}C$(5.5%), and for the comfort level, it is found that pmv index increases 8%. Second, based on the simulation of distance length with the sphere, it is more effective as it is close to the surface. If distance length is more than 0.5m, there is no effect on reduction of temperature and comfort level of indoor environment. Lastly, for the analysis by location of the introduced water space, simulation is undertaken by dividing the water space (14% of the indoor size) with front, side, rear and center types. Temperature reduction effect is found to be : front type ($-1.53^{\circ}C$), side type ($-0.82^{\circ}C$), rear type ($-0.44^{\circ}C$), center type ($-0.28^{\circ}C$), respectively. The indoor environment change data by introduction of water space, found in this research, is at initial phase, but it is deemed to be a basic data to refer when planning actual water space.

Variations of Concentration Levels of Volatile Organic Compounds in the Indoor Air due to Floor Waxing (왁스 청소에 기인한 실내 공기 중 휘발성 유기화합물의 농도변화)

  • 김만구;박춘옥;권영진;이용근;이대운
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.3
    • /
    • pp.221-229
    • /
    • 1997
  • Wax is a protectant for floors that is used widely in Korea and is considered an emission source of volatile organic compounds (VOCs) in the indoor environment. This study examined the concentration change of indoor VOCs due to waxing and also due to wiping the floor with an oiled dustcloth. VOCs were identified using a cryogenic concentration/thermal desorption system with capillary GC that utilized a liquid nitrogen cryostat and induction heating. The major components emitted from the waxing were nonane, decane, undecane, $C_2$-benzene, and $C_3$-benzene. The concentrations of nonane were 1,276 $\mu\textrm{g}$/㎥ an hour after wax applications, 832 $\mu\textrm{g}$/㎥ after 3 days, and less than 10$\mu\textrm{g}$/㎥) after 15 days. Another emission source of VOCs in indoor was the oiled dustcloth used for cleaning the floor. The oiled dustcloth gave VOCs concentrations three times higher than the normal undusted floor.

  • PDF

Management Condition on Indoor Environment and Hygiene of Childcare Center -Focusing on Cheongju- (어린이집 보육공간의 실내환경 및 공간위생 관리실태 - 청주시를 중심으로 -)

  • Choi Yoon-Jung
    • Korean Journal of Human Ecology
    • /
    • v.9 no.2
    • /
    • pp.5-20
    • /
    • 2006
  • This study was a preliminary investigation into improving the environmental and healthy quality of childcare centers. The purpose of this study was to determine the management condition on indoor environment and hygiene of childcare centers in Cheongju. Questionnaire survey was carried out from 11st to 26th of August 2004 by mail. Respondents were consisting of 55 teachers, an executive of each childcare center in Cheongju. From the survey results, there were some problems in 'empty period after remodeling work for preventing sick house syndrome', 'humidity controling', 'glare controling', 'indoor or outdoor noise controling', 'cleaning frequency of each room', 'washing method of toys', 'laundry frequency of rag doll and bedclothes'. So, we need to establish the regulations or give some educations and informations about indoor environment and hygiene to administrators of childcare centers.

  • PDF

The Analysis of Indoor Thermal Environment at the Korean Traditional House in the Winter (실측을 통한 동절기 전통가옥의 실내온열환경 분석)

  • Hwang, Hyo-Keun;Lim, Jong-Yeon;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.324-329
    • /
    • 2008
  • Recently with the demand of well-being is increased, the demand for indoor thermal environment and air quality is increased. According to this circumstance, many people in Korea note the traditional architecture that is made by natural materials, such as a soil, stone and wood. However, few researches regarding the indoor thermal environmental characteristics of the Korean traditional houses is reported. In this study we analyzed the indoor thermal environment for Han-ok through field measurement. Moreover, based on the field measurement results. indoor thermal comfort in Han-ok is analyzed.

  • PDF

Development of an Integrated Multizone Model for Indoor Air Environment Prediction (실내공기환경 예측을 위한 통합 다구획 모델의 개발)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.17 no.9
    • /
    • pp.993-1003
    • /
    • 2008
  • Interior space in most buildings is divided into several zones. The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. An integrated multizone model to predict these environmental factors simultaneously was developed. Also, a computer program for this model was written by the language of VISUAL BASIC. The proposed model was applied to a apartment with five rooms that had been tested by Chung. Comparison of predicted results by this study with measured results by Chung showed that their variations were within 14% for airflow rates, 1% for temperatures, 12% for humidities, and 5% for concentrations. It was seen that the opening operation schedule of building has a significant effect on the air moisture md contaminant removal. Thus, this model may be available for predicting the indoor air environment and may be contributed to design the ventilation plan for controling of indoor air quality.

Study on the Temperature and Humidity Control Performance of Hwang-toh Finish (황토 마감재의 온도 및 습도 조절성능에 대한 실험적 연구)

  • Lee, Kyu-In;Yeom, Dongwoo
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.99-106
    • /
    • 2012
  • This research tried to analyze the effects of ecological materials 'hwang-toh (yellow soil)' on indoor environments. For this purpose, two full scale mock-ups were constructed: one with silk wall paper, which is generally used for indoor finishing and the other with hwang-toh, which is the ecological material for wall finishing. Comparison and performance evaluations were conducted, and the effects of hwang-toh finishing on a humid indoor environment were verified. Through this research, it was verified that a hwang-toh plaster finish is effective in maintaining the comfort of an indoor environment.

Performance Evaluation of Coordinated Multi-Point Transmission and Reception in Indoor Mobile Communication Systems

  • Lee, Woongsup;Lee, Howon
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.3
    • /
    • pp.167-172
    • /
    • 2013
  • Recently, mobile communication systems are suffering from exponentially increasing data traffic. As a promising solution to the increase in data traffic, a coordinated multi-point transmission and reception (CoMP) scheme has been proposed. Although a great deal of research has been done on this new technology, the performance of mobile communication systems with CoMP has not been evaluated properly in a typical indoor environment. To address this, we have developed a system-level simulator and evaluated the performance of mobile communication systems with CoMP. Unlike previous works, we have used an actual antenna pattern in our simulator and link-level results are properly taken into account through link-level abstraction. By using a system-level simulator, we have evaluated the performance of mobile communication systems with CoMP in an indoor environment and found that unlike an outdoor cellular environment, CoMP may not improve the performance of overall mobile communication systems in an indoor environment.