Development of an Integrated Multizone Model for Indoor Air Environment Prediction  

Cho, Seok-Ho (Department of Environmental Administration, College of Applied Science, Catholic University of Pusan)
Publication Information
Journal of Environmental Science International / v.17, no.9, 2008 , pp. 993-1003 More about this Journal
Abstract
Interior space in most buildings is divided into several zones. The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. An integrated multizone model to predict these environmental factors simultaneously was developed. Also, a computer program for this model was written by the language of VISUAL BASIC. The proposed model was applied to a apartment with five rooms that had been tested by Chung. Comparison of predicted results by this study with measured results by Chung showed that their variations were within 14% for airflow rates, 1% for temperatures, 12% for humidities, and 5% for concentrations. It was seen that the opening operation schedule of building has a significant effect on the air moisture md contaminant removal. Thus, this model may be available for predicting the indoor air environment and may be contributed to design the ventilation plan for controling of indoor air quality.
Keywords
Indoor air environment; Multizone model; Thermal model; Airflow model; Humidity model; Concentration model;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Ohira N., Yagawa N., Gotoh N., 1993, Development of a measurement system for multizone infiltration, ASHRAE Transactions, 99, 692-698
2 Walton G. N., 1982, Airflow and multiroom thermal analysis, ASHRAE Transactions, 88(2), 78-91
3 Walton G. N., 1984, A computer algorithm for prediction infiltration and interoom airflows, ASHRAE Transactions, 90(1B), 601-610
4 Walton G. N., 1989, Airflow network models for element- based building airflow modeling, ASHRAE Transactions, 95(2), 611-620
5 Diasty R., Fazio P., Budaiwi I., 1992, Modelling of indoor air humidity : the dynamic behavior within an enclosure, Energy and Building, 61-73
6 Waters J. R., Simons M. W., 1987, The evalution of contaminant concentrations and airflows in a multizone model of a building, Building and Environment, 22(4), 305-315   DOI   ScienceOn
7 Chung K. C., 1996, Development and validation of a multizone model for overall indoor air environment prediction, HVAC & R Research, 2(4), 376-385   DOI   ScienceOn
8 조석호, 양성환, 이봉헌, 정성욱, 이병호, 1998, 실 내공기질 평가를 위한 2구획 모델의 개발, 한국환경과학회지, 7(6), 745-751
9 조석호, 2000, 다구획 모델에 의한 실내공기질의 평가, 지산대학 논문집, 18, 181-192
10 조석호, 2001, 다구획 실내환경에서의 공기유동량 의 예측, 부산가톨릭대학교 논문집, 1, 175-183
11 Zhang J. S., 2005, Combined heat, air, moisture, and pollutants transport in building environmental systems, JSME International Journal, Series B, 48(2), 182-190   DOI   ScienceOn
12 Wadden R. A., Scheff P. A., 1983, Indoor air pollution, John Wiley & Sons, Inc., 105-132
13 Axley J. W., 1989, Multi-zone dispersal analysis by element assembly, Building and Environment, 24(2), 113-130   DOI   ScienceOn
14 Bauman F. S., Faulkner D., Arens E. A., Fisk W. J., Johnston L. P., McNeel P. J., Pih D., Zhang H., 1992, Air movement, ventilation, and comfort in a partitioned office space, ASHRAE Transactions, 98(1), 756-780
15 Shair F. H., Heitner K. L., 1974, Theoretical model for relating indoor pollutant concentrations to those outside, Environ. Sci. Tech., 8, 441-451   DOI   ScienceOn