• Title/Summary/Keyword: Indoor and outdoor

Search Result 1,342, Processing Time 0.038 seconds

Environmental Noise Prediction of Power Plants (발전소 환경소음 예측)

  • 조대승;유병호
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.621-629
    • /
    • 1997
  • For computer aided design and costruction of low noisy power plants, indoor and outdoor noise prediction program has been developed. The program utilizes the predefined data of noise sources and building materials and has the faculty to estimate the source level using the empirical formula in case of the measured data not being available. In the noise prediction, the mutual noise propagation between indoor and outdoor sites are considered. The outdoor noise source in the calculation of geometric divergence effects is modelled as the omni-directional finite line or planar source according to the source geometry and the receiving points. Outdoor noise prediction is carried out to consider the diffraction effect due to plant structures as well as the attenuation effect due to atmospheric absorption and soft ground. The results of indoor and outdoor noise prediction for a recently constructed diesel engine power plant show good agreement with the measured.

  • PDF

Personal Exposure Level and Health Risk Assessment of Nitrogen Dioxide in an Industrial Area (일부 공단지역 내 이산화질소의 개인노출 농도 및 건강위해성평가)

  • Jeon, Young-Taek;Yang, Won-Ho;Yu, Seung-Do;Lee, Jong-Dae;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.199-206
    • /
    • 2008
  • This study was conducted to estimate nitrogen dioxide levels and health risk in various locations/situations for two groups. The nitrogen dioxide levels were measured for residents of a study group (industrial area within 5 km) and a control group (15 km farther), respectively using the nitrogen dioxide filter badge as a passive sampler from August, 2006 to September, 2006. The means of indoor, outdoor, work and personal levels of nitrogen dioxide were $34.65{\pm}1.95\;{\mu}g/m^3$, $34.83{\pm}11.78\;{\mu}g/m^3$, $34.98{\pm}19.11$ and $35.38{\pm}10.74$ respectively in the study area. Mean ratio of indoor to outdoor $NO_2$ concentration was 0.99. The means of indoor, outdoor and personal level of nitrogen dioxide were $23.66{\pm}7.19\;{\mu}g/m^3$, $18.22{\pm}4.06\;{\mu}g/m^3$ and $27.27{\pm}18.93\;{\mu}g/m^3$ respectively in the control area. Mean ratio of indoor to outdoor $NO_2$ concentration was 1.39. People spent 80.9% of their time in indoor at the study area and 76.9% at the control area. The percentages of time spent in outdoor were 14.9% and 20.9% at the study area and the control area respectively. The percentages of time spent in a car were 4.2% and 2.2% in the study and control areas respectively. The levels of indoor, outdoor, workplace nitrogen dioxide in the study area and the control area were found below the permissible level of health-hazardous effects.

Evaluation of Passive Monitor for the Measuring of Personal Exposure to Nitrogen Dioxide in Indoor and Outdoor Air (실내 및 실외 공기중 이산화질소의 개인 노출량 측정을 위한 수동식 시료채취기의 성능평가)

  • 양원호;이기영;백도명
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.625-631
    • /
    • 2000
  • Practical devices for measuring personal exposure to nitrogen dioxide(NO$_2$) have been made for epidemiological studies of the health effects of air pollution Standard methods for NO$_2$ measurement such as the chemiluminescent method and Saltzman method are not suitable for personal exposure because they are heavy, large and complicated to operate. In this study, a passive monitor was tested for the measurements of indoor and outdoor NO$_2$ level. Through a comparative analysis of data sets obtained by on-site chemiluminescence system, we assessed the accuracy and precision of NO$_2$ passive monitors. We also examined the possibility of passive monitor in the study of indoor, outdoor and personal NO$_2$ exposure. The accuracy and precision of NO$_2$ passive monitor were analyzed assuming measurements of on-site chemiluminescence system is reference value and using duplicated measure- ments, respectively. From these analysis the NO$_2$ passive monitor was useful for measuring indoor, outdoor and personal exposure. And NO$_2$ level from on-site chemiluminescence systems could not properly represent the personal NO$_2$ exposure as well as indoor and outdoor level of ones house. Personal exposures were correlated more strongly with indoor NO$_2$ concentrations than with outdoor NO$_2$ concentrations. Since activity pattern of each person is different, it was considered that personal daily behavior and life-style might prevent the air pollutant exposure.

  • PDF

Indoor-Outdoor Positioning Method (옥내외 겸용 측위 방법)

  • Yim Jae-Geol;Lee Gye-Young;Shim Kyu-Bark
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.9
    • /
    • pp.1222-1230
    • /
    • 2006
  • Location-Based Service (LBS) is a service provided to the user based on the user's current geographic location. Since LBS provides a higher value-added service, LBS has been applied on various businesses, industries and even on personal lives. Positioning users is the essential technology in building an LBS system. Thanks to GPS (Global Positioning System), Positioning outdoor is successfully used in practice. However, there is not a general solution for indoor positioning yet, even though many strategies for indoor positioning have been introduced. One of the reasons for the lack of successful indoor positioning is that most of the existing indoor positioning strategies require special equipments dedicated for positioning. This paper introduces an indoor positioning strategy that does not require any additional equipments. Integrating our indoor positioning strategy with GPS-based outdoor positioning, we have implemented an indoor-outdoor positioning system. Experimental results of the system is also introduced.

  • PDF

Indoor and Outdoor $NO_2$ Concentration of Shoe-stall near Busy Road and $NO_2$ Decay by Distance from Roadside - Comparative Study between Seoul and Asan - (도로변 구두수선대 실내.외의 이산화질소 농도 및 거리에 따른 이산화질소 감소 - 서울시와 아산시의 비교 연구 -)

  • 양원호;손부순;박종안;김종오
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.85-91
    • /
    • 2002
  • Workers who work at indoor and outdoor environment near busy road are suspected to be exposed to high-elevated air pollutant levels during working hours. This study evaluated the working-time nitrogen dioxide ($NO_2$) exposure for workers (repairmen and polishers) of shoe-stalls. Since shoe-stalls have particularly been located near busy road in Korea, workers might be high exposure to $NO_2$ from traffic exhaust as well as indoor sources of shoe-stall such as portable gas range (butane gas) during working hours. In this study, we measured the indoor and outdoor $NO_2$ concentrations of shoe-stalls. Simultaneously, outdoor $NO_2$ concentrations of building through sidewalk from shoe-stall were measured. High $NO_2$ exposure for workers of shoe-stalls was considered to be inflow of outdoor source of exhausted emission from vehicles and indoor source from usage of gas range to polish the shoe. Indoor/outdoor $NO_2$ concentration ratio ($0.94{\pm}0.22$) in Seoul was higher than that ($1.06{\pm}0.34$) in Asan, because ambient $NO_2$ level was high in Seoul and usage of gas range was prevalent in Asan. According to $NO_2$ concentrations by distance from roadside to building through sidewalk, $NO_2$ concentrations showed the decreased trend with distance. The results of this study can be utilized by municipal authorities in urban planning for evaluating effects of future traffic planning and land use.

GNSS-UWB Hybrid Positioning System for Indoor and Outdoor Seamless Positioning (산업현장에서의 실내외 연속측위를 위한 GNSS-UWB 하이브리드 측위 시스템)

  • Yong Jun, Chang;Joung Wook, Lee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.27 no.1
    • /
    • pp.139-142
    • /
    • 2023
  • In this paper, we propose a GNSS-UWB hybrid positioning system for indoor and outdoor seamless positioning. Fusion of GNSS and inertial sensors has been widely used as a method for estimating positions in places where GNSS reception sensitivity is low, and UWB technology, which started as a short-range wireless communication technology, is widely used indoors where GNSS is completely blocked. This paper proposes a method of mutual correction and fusion of the location information collected through GNSS and the location information collected from the UWB indoor positioning system when indoor and outdoor work occurs continuously and repeatedly, such as in an industrial site.

Volatile Organic Compounds Concentrations and Its Personal Exposure in Indoor and Outdoor Environments in Summer (하계 실내 및 실외환경의 공기 중 휘발성 유기화합물 농도 및 개인노출)

  • 양원호;손부순;박종안;장봉기;박완모;김윤신;어수미;윤중섭;류인철
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.967-976
    • /
    • 2003
  • Volatile organic compounds (VOCs) are present in essentially all natural and synthetic materials from petrol to flowers. In this study, indoor and outdoor VOCs concentrations of houses, offices and internet-cafes were measured and compared simultaneously with personal exposures of each 50 participants in Asan and Seoul, respectively. Also, factors that influence personal VOCs exposure were statistically analyzed using questionnaires in relation to house characteristics, time activities, and health effects. All VOCs concentrations were measured by OVM passive samplers (3M) and analyzed with GC/MS. Target pollutants among VOCs were Toluene, o-Xylene, m/p-Xylene, Ethylbenzene, MIBK, n-Octane, Styrene, Trichloroethylene, and 1,2-Dichlorobenzene. Indoor and outdoor VOCs concentrations measured in Seoul were significantly higher than those in Asan except Ethylbenzene. Residential indoor/outdoor (I/O) ratios for all target compounds ranged from 0.94 to 1.51 and I/O ratios of Asan were a little higher than those of Seoul. Relationship between personal VOCs exposure, and indoor and outdoor VOCs concentrations suggested that time-activity pattern could affect the high exposure to air pollutant. Factors that influence indoor VOCs level and personal exposure with regard to house characteristics in houses were building age, inside smoking and house type. In addition insecticide and cosmetics interestingly affected the VOCs personal exposure. Higher exposure to VOCs might be caused to be exciting increase and memory reduction, considering the relationship between measured VOCs concentrations and questionnaire (p<0.05).

Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area (대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

Temporal Characteristics of Selected Volatile Organic Compounds in Urban High-Stories Urban Apartments

  • Shin, Seung Ho;Kim, Ji-Hoon;Jo, Wan Kuen
    • Journal of Environmental Science International
    • /
    • v.24 no.10
    • /
    • pp.1273-1283
    • /
    • 2015
  • In present study, the temporal characteristics of nine selected volatile organic compounds (VOCs), including four alcohol, 2 aldehyde, and 3 ketone compounds, in high-stories urban apartments over a 2-y period were investigated. The indoor VOC concentrations had generally a decreasing trend over the 2-y follow-up period. For examples, the 2E1H indoor concentration decreased from $10.8{\mu}g/m^3$ for the first two months to $5.1{\mu}g/m^3$ for the last two months. In addition, the DCA and ACT indoor concentrations decreased from 5.0 and $14{\mu}g/m^3$ for the first two months to 2.2 and $6.4{\mu}g/m^3$, respectively, for the last two months. The indoor-to outdoor concentration ratios over the 2-y period were much greater than 1, indicating that indoor VOC concentrations were higher than the outdoor VOC concentrations. Similar to those of the individual VOCs, the indoor-to-outdoor concentration ratios of all three VOC groups were higher than 1 over the 2-y follow-up period, suggesting higher indoor concentrations of the three VOC groups than outdoor concentrations. In consistence with the results of VOC indoor concentrations, the VOC emission rates decreased gradually as time passed, due to the decreased VOC emission strengths of indoor sources. Finally, there was an initial sharp decrease in the indoor VOC concentrations followed by a slower decrease, indicating a multi-exponential decay model for the target VOCs, which was demonstrated by comparison of the residuals and the adjusted coefficient of determination associated with the one and two-exponential fits of each data set.

Comparative Study on Nitrogen Dioxide Exposure of Female Teachers from Kindergarten and House Wives (유치원 여교사(女敎師)와 전업주부(主婦)의 이산화질소 노출비교 및 평가)

  • 양원호;김순복;배현주;이영미;정문호;정문식
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Since most people spend over 80% of their time indoor, indoor air quality tends to be the dominant contributor to personal exposure. In this study, indoor and outdoor $NO_2$concentrations were measured and compared with simultaneously personal exposures of 27 house-wives and female workers of kindergarten. Time activity pattern and house characteristics were used to determine the effects of these factors on personal exposure. Since house-wives student spent most their times in indoor with mean of 89.8%, their $NO_2$ exposure was associated with indoor $NO_2$ level(r= 0.92) rather than outdoor $NO_2$ level(r= 0.87). female workers were also associated with indoor $NO_2$ level(r= 0.70) though sample number were small. Using time-weighted average model, $NO_2$ exposures of house-wives were estimated by $NO_2$ measurements in indoor home and outdoor home levels. Estimated $NO_2$ personal exposures were significantly correlated with measured $NO_2$ personal exposures (r= 0.90). These results might mean that air pollutants exposure of old and feeble persons, and infants could be estimated by measuring concentrations of indoor home.

  • PDF