• Title/Summary/Keyword: Indoor air environment

Search Result 1,063, Processing Time 0.026 seconds

Analysis and Suggestion of Environment-friendly Interior Finishing Materials for Aged Apartment Remodeling (노후 공동주택 리모델링의 친환경 실내 마감재료 분석 및 제안)

  • Kim, Ki-Hyun;Kim, Kyung-Rai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.2
    • /
    • pp.118-126
    • /
    • 2007
  • Environmentally Sound and Sustainable Development (ESSD)" is a key word in recent years. The construction industry, have put a great influence on ergonomic and sustainable environment. Recently, "green building certifications", such as Indoor Air Quality (IAQ) and eco-friendly material regulation have been established. With this regard, new construction and aged-housing remodeling projects are required to meet these certification criteria. Apartment residents have great concern on eco-product, since many cases are reported that Sick Building Syndrome is caused by toxic substance from building materials. Aged-housing remodeling construction has a unique characteristic in that the residents are already determined prior to construction execution. Therefore, the analysis of resident's need for building materials in aged-housing remodeling is relatively easy compared to new building construction. As such, it is very important to analyze their preferences for eco-friendly materials prior to project execution. The purpose of this study is to find the needs of residents and priority of their needs. Based on their needs and priority, this paper provides a new strategy in using environment-friendly materials and maximizing their satisfaction level when aged housing remodeling is constructed. In addition, this paper provide new criteria in selecting new developed environmental materials in remodeling projects for the purpose of improving the safety and health level in construction industry.

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

Comparison of VOCs Concentration Characteristic According to Measurement Methods in Exhibition Hall (휘발성유기화합물(VOCs)의 측정방법에 따른 유물 전시관 내 농도 분포 특성 비교)

  • Lim, BoA;Lee, Sun Myung
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.25-44
    • /
    • 2014
  • In this study, measured annual year and seasonal concentrations of VOCs by Active type and Passive type using the measurement and analysis method in the exhibition hall and outdoor. It was compared with the correlation between the methods according the comparison of methods to measured concentrations. As a results, the annual average concentrations of TVOC in exhibition room($906.5{\mu}g/m^3$) was greater than for most of the study period, more than 1.8 times the standard in the Ministry of Environment. ${\Sigma}VOCs$ concentration of exhibition room by Active type was higher than Passive type. Some VOCs was decreased with the lapse of time a temporary increase tendencies was. The annual average I/O ratio of TVOC was 9.0, ${\Sigma}VOCs$ was confirmed to occur in a large amount inside the exhibition hall ${\Sigma}VOCs$ was studied to 34.0. Correlation coefficient of ${\Sigma}VOCs$ was 0.367. Toluene was 0.567 that the survey was the largest analysis to the relationship between the two methods.

  • PDF

Photocatalysis of o-, m- and p-Xylene Using Element-Enhanced Visible-Light Driven Titanium Dioxide

  • Kim, Jong-Tae;Kim, Mo-Keun;Jo, Wan-Kuen
    • Journal of Environmental Science International
    • /
    • v.17 no.11
    • /
    • pp.1195-1201
    • /
    • 2008
  • Enhancing with non-metallic elemental nitrogen(N) is one of several methods that have been proposed to modify the electronic properties of bulk titanium dioxide($TiO_2$), in order to make $TiO_2$ effective under visible-light irradiation. Accordingly, current study evaluated the feasibility of applying visible-light-induced $TiO_2$ enhanced with N element to cleanse aromatic compounds, focusing on xylene isomers at indoor air quality(IAQ) levels. The N-enhanced $TiO_2$ was prepared by applying two popular processes, and they were coated by applying two well-known methods. For three o-, m-, and p-xylene, the two coating methods exhibited different photocatalytic oxidation(PCO) efficiencies. Similarly, the two N-doping processes showed different PCO efficiencies. For all three stream flow rates(SFRs), the degradation efficiencies were similar between o-xylene and m,p-xylene. The degradation efficiencies of all target compounds increased as the SFR decreased. The degradation efficiencies determined via a PCO system with N-enhanced visible-light induced $TiO_2$ was somewhat lower than that with ultraviolet(UV)-light induced unmodified $TiO_2$, which was reported by previous studies. Nevertheless, it is noteworthy that PCO efficiencies increased up to 94% for o-xylene and 97% for the m,p-xylene under lower SFR(0.5 L $min^{-1}$). Consequently, it is suggested that with appropriate SFR conditions, the visible-light-assisted photocatalytic systems could also become important tools for improving IAQ.

Application of Field and Laboratory Emission Cell (FLEC) to Determine Formaldehyde and VOCs Emissions from Wood-Based Composites

  • Kim, Sumin;Kim, Jin-A;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.24-37
    • /
    • 2007
  • The Korean Ministry of Environment started controlling indoor air quality (IAQ) in 2004 through the introduction of a law regulating the use of pollutant emitting building materials. The use of materials with formaldehyde emission levels above $1.25 mg/m^2{\cdot}h$ (JIS A 1901, small chamber method) has been prohibited. This level is equivalent to the $E_2$ grade ($>5.0mg/{\ell}$) of the desiccator method (JIS A 1460). However, the $20{\ell}$ small chamber method requires a 7-day test time to obtain the formaldehyde and volatile organic compound (VOC) emission results from solid building interior materials. As a approach to significantly reduce the test time, the field and laboratory emission cell (FLEC) has been proposed in Europe with a total test time less than one hour. This paper assesses the reproducibility of testing formaldehyde and TVOC emissions from wood-based composites such as medium density fiberboard (MDF), laminate flooring, and engineered flooring using three methods: desiccator, perforator and FLEC. According to the desiccator and perforator standards, the formaldehyde emission level of each flooring was ${\le}E_1$ grade. The formaldehyde emission of MDF was $3.48 mg/{\ell}$ by the desiccator method and 8.57 g/100 g by the perforator method. To determine the formaldehyde emission, the peak areas of each wood-based composite were calculated from aldehyde chromatograms obtained using the FLEC method. Formaldehyde, acetaldehyde, propionaldehyde, butyraldehyde and benzaldehyde were detected as aldehyde compounds. The experimental results indicated that MDF emitted chloroform, benzene, trichloroethylene, toluene, ethylbenzene, m,p-xy-lene, styrene, and o-xylene. MDF emitted significantly greater amounts of VOCs than the floorings did.

An Evaluating of Daylighting Performance by Venetian Blind Shapes Type Change - Centre on Radiance Program (베네치안 블라인드 슬랫각도 형태변화에 따른 주광성능에 관한 연구 - Radiance Program 중심으로)

  • Lim, Tae Sub;Park, Jong Myung;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Current Architectural Facade Designs have been trending to increased glass areas resulting in increasing impact on interior lighting and daylighting. In regards to indoor environmental quality, the increase in window space has a large impact on the daylighting received which ultimately impacts the liveability of a space. Especially when considering seasons, in the summer, excessive daylighting can result in glare as well as put an increased load in conditioning the air space further reducing energy efficiency. As a result, in order to improve the sustainability performance of a building, it is important to limit the natural lighting exposure to properly meet the needs and conditions of the building occupants. One of the most representative features to limit excessive sunlight exposure, is to incorporate operable blind systems. To this end, this research has been based on simulations performance through the Radiance Program. Radiance is capable of analyzing performance of daylight and impact of sunlight. Through analysis of different slat angles and blind shapes, impact and minimization of energy usage was evaluated. Furthermore, seasonal analysis was performed in order to understand the effects of seasonal climate factors. Ultimately this research provides an analysis of operable blinds optimization and effects of blind shape, control factors and angle of shading.

Characteristic of Cabin Temperature According to Thermal Load Condition of Heat Pump for Electric Vehicle (전기자동차용 히트펌프의 열 부하 조건에 따른 캐빈온도 특성)

  • Park, Ji Soo;Han, Jae Young;Kim, Sung-Soo;Yu, Sang Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.2
    • /
    • pp.85-91
    • /
    • 2016
  • The Positive Temperature Coefficient (PTC) is used for cabin air heating of a battery electric vehicle, which is different from conventional vehicles. Since the PTC heater consumes a large quantity of power in a parasitic manner, many valuable studies have been reported in the field of alternative heat pumps. In this study, a model for an R134a heat pump taking into account the thermal environment of the cabin was developed for a MATLAB/SIMULINK(R) platform. Component and cabin models are validated with reference values. Results show that the heat pump is more competitive for parasitic power consumption over all ambient temperature conditions. Additionally, the method of waste heat recovery to overcome disadvantages when temperatures are below zero is applied to efficiently operate the heat pump.

Effect of Diesel Exhaust Particles (DEP) on the Activity of Phospholipase D (PLD) in RAW 264.7 Cells

  • Nam Hae-Yun;Shin Hyun-Yong;Ahn Eun-Kyung;Kim Hyung-Jung;Lim Young
    • Toxicological Research
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 2006
  • Diesel exhausted particles (DEP), a kind of fine particles with aerodynamic diameters less than $2.5{\mu}m$ (PM2.5), is of great concern to human health because they remain in atmosphere for long periods, invade an indoor air environment, and can be breathed most deeply into lung and reached the alveoli because of their small size ($0.1{\sim}0.4\;{\mu}m$ in diameter). Epidemiological and experimental studies suggested that DEP may play an active role in the increased respiratory mortality and morbidity. In addition to their physical characteristics, the chemical components including polyaromatic hydrocarbon (PAH) are regarded as a carcinogen causing pulmonary tumors. PLD plays an important role in cell proliferation with various physiological phenomena and affects other enzymes by activating signal transduction pathway. We investigated the cytotoxic mechanism of DEP on RAW 264.7 cells focusing on the role in activation of PLD. Our results suggested DEP induced PLD activity through a specific signaling pathway involving phospholipase $A_2$, PLC, PKC and $Ca^{2+}$ mobilization.

Research Analysis of the Therapeutic Factors in the Contact with Plant.Nature in Horticultural Therapy (원예치료에서 식물.자연 접촉이 지니는 치료적 요인 연구동향과 전망)

  • Choi, Min-Hee;Cho(Jo), Tae-Dong;Suh, Jeung-Keun
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.517-525
    • /
    • 2010
  • Horticultural therapy is a complementary therapy by trained professionals utilizing plant and horticultural activities as media to pursue the positive change of clients, which resulting from stimuli of plant nature, activities, and interaction with other people. Outdoor horticultural activities provide clients with the opportunities of the contact to nature such as fresh air and sunlight as well as plants. But the importance of plant nature to client's health has not been fully acknowledged compared to that of therapist's role and activities in horticultural therapy in Korea. In horticultural therapy it is possible for client to participate on the various levels from passive viewing to active gardening according to the client's ability. Therefore it is necessary for horticultural therapists to consider the therapeutic factors of plant nature to maximize the therapeutic effect of horticultural therapy. The purpose of the research is to clarify the therapeutic factors in the contact of client with plant nature and to emphasize those importance in horticultural therapy. From the review of the experimental researches five therapeutic factors were revealed: Natural light, plant natural view, natural sound, aroma(volatile oils of plants), and plant itself. This paper raises the importance of outdoor activities in horticultural therapy and the necessity for severely handicapped clients to the contact with plant nature, though passively.

Development of the Sentiment Indicators of Housing Welfare (주거복지지표 개발에 관한 연구 II - 수요자 측면의 주거복지체감지표와 지수를 중심으로 -)

  • Jee, Eun-Young;Eun, Nan-Soon;Hong, Hyung-Ock
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.85-92
    • /
    • 2008
  • The aim of this research is to develop the sentiment indicators of housing welfare for evaluating housing welfare policies conducted by the Korean government. The methods of this research are used by analysis of related documents, FGI (Focus Group Interview), and survey. The survey was made by experts and consumers. To analyze the survey, this research also uses confirmatory factor analysis by SPSS (Statistical Package for the Social Science) program, AHP (Analytical Hierarchy Process) by Expert Choice program, frequency, average, percentages, Factor analysis etc. As a result of this research, selected housing welfare indicators are settled as follows: In the housing welfare aspect, 11 indicators in the department of 'Housing Satisfaction' and 11 indicators in the department of 'Community Satisfaction' (22 in total) are suggested. The indicators are 1) Water Supply and Distribution Equipment 2) Heating equipment 3) the size of the exclusive residential area 4) the number of rooms 5) Ventilation and Lighting 6) Sound Insulation (Indoor Noise) 7) Air Pollution/Odor 8) House Deposit 9) Rent Paid 10) Maintenance (Dwelling) Cost 11) The length of Occupation 12) Proximity to Welfare Facilities 13) Educational Environment 14) Convenience of Facilities (shops, hospitals etc.) 15) Convenience of Transportation and Commuting 16) Distance from Workplace 17) Landscape and Green Space (Tree, Flowers, Grass etc.) 18) Vandalism (Destruction Behavior, graffiti etc.) 19) Privacy 20) Noise in Public Places (Drinking, Loudly Talking etc.) 21) Safety from Crime 22) Safety from a Disaster. As of 2007, the housing welfare sentiment index is measured by the survey of 1,000 inhabitants in the public housing, which shows 3.51.