• Title/Summary/Keyword: Indoor Pollutant

Search Result 141, Processing Time 0.022 seconds

An Experimental Study on Indoor Pollutant Reduction of Cementitious Composite Using Charcoal and Phytoncide (숯과 피톤치드를 사용한 시멘트계 복합재의 실내 오염물질 저감에 관한 실험적 연구)

  • Jeong, Hyeon-Woo;Jeong, We-Young;Jung, Yoong-Hoon;Han, Song-Yi;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.13-19
    • /
    • 2021
  • In modern society, indoor activities time is increasing due to industrial development. Interest in indoor air quality is increasing as indoor activity time increases. The main causes of indoor air pollution are formaldehyde which a chemical cause, and fungi which a biological cause. Phytoncide effectively reduces Formaldehyde and Fungi. Charcoal which possess porous-structure has a good absorbance of pollutants. In this study, the authors manufactured functional cement matrix using by phytoncide and charcoal to remove formaldehyde and fungi. In this study, Functional cement matrix reduced formaldehyde and Fungi and effectively improve indoor air quality.

Estimating Personal Exposures to Air Pollutants in University Students Using Exposure Scenario (노출 시나리오를 이용한 대학생들의 유해 공기오염물질 노출 추정)

  • Kim, Sun-Shin;Hong, Ga-Yeon;Kim, Dong-Keon;Kim, Sung-Sam;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.47-57
    • /
    • 2013
  • Studies evaluating the health effects of hazardous air pollutants assume that people's exposure to typical pollutant level is the same as specific regional pollutant level. However, depending on social and demographic factors, time-activity pattern of people can vary widely. Since most people live in indoor environments over 88% of the day, evaluating exposure to hazardous air pollutants is hard to characterize. Objective of this study was to estimate the exposure levels of university students of $NO_2$, VOCs(BTEX) and $PM_{10}$ using the scenarios with time-activity pattern and indoor concentrations. Using data from time-use survey of National Statistical Office in 2009, we investigated time-activity pattern of university students and hourly major action. A total of 1,057 university students on weekday and 640 on weekend spent their times at indoor house 13.04 hr(54.32%), other indoors 7.70 hr(32.06%), and transportation 2.36 hr(9.83%). Indoor environments in which university students spent their times were mainly house and school. Air pollutants concentrations of other indoor environments except house and school such as bar, internet cafe and billiard hall were higher than outdoors, indicating that indoor to outdoor ratios were above 1. According to three types of exposure scenarios, exposure to air pollutants could be reduced by going home after school.

Exposure Assessments for Children in Homes and in Daycare Centers to NO2, PMs and Black Carbon

  • Lee, Jae Young;Kim, Changhyeok;Kim, Jongbum;Ryu, Sung Hee;Bae, Gwi-Nam
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.204-214
    • /
    • 2018
  • Indoor air quality was investigated in homes and daycares located in areas with heavy traffic in Seoul, South Korea from November 2013 to January 2014. Indoor and outdoor air quality measurements were collected for 48 hours in four children's homes and daycare centers. The I/O ratio (Indoor to outdoor ratio) for each major air pollutant ($NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$) was calculated, and $NO_2$ and $PM_{10}$ concentration profiles were analyzed based on indoor activity diaries recorded during the 48 hours. Most I/O ratios for $NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$ at daycare centers were less than one. At homes, I/O ratios for black carbon, $PM_{10}$, and $PM_{2.5}$ were less than one; however, most I/O ratios for $NO_2$ were greater than one due to the usage of gas stoves. The children's exposure to indoor air pollutants was calculated using a time-weighted average exposure method, and the daily intake level for each pollutant was determined.

Improvement of the Architectural Environment by Applying Photocatalyst Building Materials and Ventilation Systems (광촉매 건축자재와 환기시스템 적용에 따른 건축 환경 개선 방안)

  • Yong Woo Song;Seong Eun Kim;Se Hyeon Lim;Sung Jin Sim
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.103-110
    • /
    • 2023
  • People who spend most of their day indoors are continuously exposed to internally and externally generated indoor pollutants. According to a 2022 report from the World Health Organization (WHO), air pollution is the cause of more than 7 million deaths annually worldwide, emphasizing the seriousness of indoor air pollutants. Air pollutants include nitrogen oxides (NOx), formaldehyde (HCHO), and volatile organic compounds (VOCs), which have serious effects on the human body. Photocatalyst is a material that can remove these indoor air pollutants. Photocatalysts not only have the ability to remove dust precursors, but also have antibacterial, sterilizing, and deodorizing functions, making them effective in improving indoor air quality. This study suggests areas and methods in which photocatalysts can be applied to buildings. Fields of application include interior and exterior construction materials such as concrete, as well as organic paints and ventilation devices. If appropriate utilization plans are developed, it may be possible to improve the built environment through reduced indoor and outdoor pollutant levels.

Effect of Contaminant Source Location on Indoor Air Quality

  • Lee, Hee-Kwan;Kim, Shin-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.E
    • /
    • pp.1-7
    • /
    • 1998
  • This paper presents an experimental study for understanding the indoor air quality in a room. A model room, which had a ceiling-mounted supply and a sidewall-mounted exhaust, was used to examine the effect of air exchange rate (AER) and contaminant source location (CSL) as a function of the elapsed time. A tracer gas method, using carbon monoxide tracer, gas analyzers, and a data acquisition system, was applied to study the ventilation air distribution and the tracer removal efficiency, so-called pollutant removal efficiency, in the model room. The experiment was composed of two parts; firstly the AER was varied to examine its effect on the ventilation air distribution and the ventilation effectiveness and secondly both AER and CSL were considered to determine their effect on the pollutant removal efficiency. It was found that the ventilation effectiveness in the model was proportional to AER but not linearly. It was also found that changing the CSL can improve the pollutant removal efficiency. In some cases, the efficiency improvement by increasing AER was achieved by simply changing CSL.

  • PDF

Indoor Ventilation Efficiency Depending on Diffuser Inlet Angle (급기구 유입각도에 따른 실내 환기효율)

  • Jeon, Hyun-Jun;Jang, Yong-Jun;Yang, Kyung-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.349-355
    • /
    • 2011
  • In this study, numerical simulation has been conducted to investigate dispersion of a pollutant released from a new furniture, a kind of Sick Building Syndrome (SBS). A sofa which generates formaldehyde is implemented by using an immersed boundary method. Large Eddy Simulation (LES) is employed to obtain time-dependent velocity and concentration fields. It is shown that the ventilation efficiency in this room can be improved by changing inlet angle of diffuser, even though other conditions still remain unchanged. Both active diffusion near a sofa and air flow pattern are important parameters to enhance the ventilation efficiency.

Distribution of Pollutant on the Indoor Air of Passenger Car (철도차량 객차내 오염물질의 분포경향에 관한 전산해석)

  • So, Jin-Sub;Chun, Chul-Kyun;Park, Chan-Su;Choi, Ju-Seok
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.2
    • /
    • pp.7-16
    • /
    • 2003
  • The transfer of air pollutants between passenger room and service room in train are investigated by the computational analysis. The effects of service room temperature, inlet velocity, initial concentration and heating are studied. The flow induced by the difference of density between two rooms is found to take the major role in transfer of polluted air. Low temperature of service room enhances the polluted air flow into passenger room along the floor. Exhaust fan above the door between two rooms is not effective for this case. Strong inlet flow is found to suppress polluted air flow from service room. The heating of passenger room can promote air pollution.

  • PDF

The Characteristic of the Concentration Transition of Chemical Substances in Energy Saving House and Apartment House (에너지절약 주택과 일반 아파트에서의 실내 화학오염물질 농도 변화 특성)

  • Yoo, Bok-Hee;Park, Sun-Hyo
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the indoor air pollutant. Volatile Organic Compounds $(VOC_s)$ and formaldehyde have been considered as one of the main reason that causes indoor air pollutant. This study is for introducing and designing thermal performance of super energy saving building by conducting $VOC_s$ and formaldehyde concentration in the 3Liter house. The results of the measurement for 10 months showed that $VOC_s$ and formaldehyde decreased until the guideline concentration. It took about 7 months, and it appeared right after new construction. However, their levels were showed higher concentration in comparison with the ordinary residential houses (apartment house). The main difference of between newly built 3Liter house and ordinary apartment is their air changes, which are 0.67/h for 3Liter house and 4.0/h for the apartment.

A Study on the Increasement of the Indoor Amenity on the New Apartment (신축아파트의 실내거주환경개선에 관한 연구)

  • Kang Hyun-Su;Kim Sung-woong;Cho Young-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.163-166
    • /
    • 2005
  • Amenity is an essential factor of Modern Apartment. But because of many chemical products and noxious volatile organic compound(VOC) used in the apartment, many people are exposed to them. This fact implies that there can be many disease caused by them. Therefore to reduce pollutant matters inducing sick house syndrom, measures for new furniture and apartment dweller were suggested in this study.

  • PDF

Assessment of Indoor Air Quality and the Eye Symptom of Occupants in Newly-built Office Building after Planting Indoor Plants (신축사무실 내 식물 적용 후 재실자 안구 증상 및 실내공기질 평가)

  • Kim, Hyojin;Kim, Ho-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.265-274
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate relationship between worker's ophthalmoxerosis symptom and IAQ (Indoor Air Quality) variation after planting indoor plants at newly-built office building. Methods: We selected a new office building located in Sejong-si and occupants who work in the Office for study. The indoor air pollutant was investigated according to applying indoor plants. The indoor air quality of the new building was evaluated by measuring volatile organic compounds (VOCs), aldehydes, temperature and humidity. The level of dry eye symptoms was classified into normal, mild, moderate and severe by using the Ocular Surface Disease Index (OSDI). Results: There was VOCs' reduction effect according to placing indoor plants because the concentration of VOCs in newly-built government office (Sejong-si) was highly decreased when the indoor plants was placed at the office. The occupants' SBS (Sick Building Syndrome) symptoms score was gradually decreased in accordance with applying indoor plants. However, SBS symptoms score was increased when the office was not applied indoor plants. There was not statistical significance in workers' dry eye questionnaire results. Conclusions: There was reduction effect of indoor air pollutant in applied indoor plants office. Also, in case of questionnaire results of ophthalmoxerosis and SBS (Sick Building Syndrome) symptoms score were showed positive effect. This study is needed longer-term study because of complements of difference of individual sensitivity and there are some limitations due to field survey research.