• 제목/요약/키워드: Indoor Noise Level

검색결과 139건 처리시간 0.023초

실내 소음기준 설정에 관한 실험적 연구 -동일 건물내 사업장을 중심으로- (An Experimental Study on the Establishment of Indoor Noise Criteria - Focused on Korean Complex Building-)

  • 이태강;국찬;장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.9-12
    • /
    • 2008
  • There are many place of business in complex building, and recently claims of noise have increased in those buildings. It is most desirable reducing the noise problems to establish the noise criteria considering the noise source and the receiving place of business, which are derived from the dose-response of noise and results of the actual condition. The degree of response to the transmission noise could be changed with background noise level in the receiving stores. In this research, the subjective evaluation for three different background level in receiving place of business or rooms were investigated from subjective tests. The eight business sound source including aerobic music were used for the test.

  • PDF

보건의료시설의 실내 예상 평균 온열감(PMV), 이산화탄소 농도, 소음도, 조도의 통합실내쾌적도(IEQh)를 통한 연간 실내 쾌적도 평가 (Evaluation of Annual Indoor Environment Quality in Hospitals using Various Comfort-related Factors)

  • 이보람;이대엽;반현경;이세원;김규상;이기영
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.214-222
    • /
    • 2017
  • Objectives: A hospital is a complex building that serves many different purposes. The indoor environment in a hospital plays a major role in patient well-being and the work efficiency of the hospital staff. This study was conducted to evaluate overall comfort in two major hospitals over the course of one year. Methods: Various indoor environmental conditions were measured in two general hospitals for one year (April 2014 to April 2015). Monitoring alternated between the hospitals at one month per respective monitoring session. The indoor air temperature, relative humidity (RH), mean radiant temperature and air velocity were measured in order to calculate the predicted mean vote (PMV). Carbon dioxide concentration, noise level and illumination level were concurrently measured and applied to the overall IEQ acceptance model for the hospitals (IEQh). Results: The IEQh at the two general hospitals was different at five spaces within a building. The IEQh for summer and winter were significantly different. Real-time IEQh demonstrated that indoor comfort was affected by the hospital's operating hours due to operation of the HVAC system. The percentage of indoor comfort in the hospitals was higher using PMV than IEQh. Conclusion: IEQh in the hospitals was different at locations with different purposes. Indoor comfort assessment using IEQh was stricter than with PMV. Additional research is needed in order to optimize the IEQh model.

저소음 패키지형 공기조화기의 실내기 개발에 관한 연구 (Study on the Development for Low Noise Indoor Unit Package Air-Conditioner)

  • 이재효;조성철;김태헌
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.518-523
    • /
    • 2003
  • The purpose of this study was to reduce the noise emitted from the package air-conditioner. The optimum design methods of the fans ware investigated experimentally through the analysis of noise problem caused by the conventional PAC system. New PAC system had decreased 6 dBA in overall noise level as compared with the conventional system by various technology.

주거용 건물의 실내.외 항공기소음레벨 평가 (Estimation on the Interior and Outside Aircraft Noise Level of Residential House)

  • 방민;김도형;김흥식;조창근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.687-691
    • /
    • 2007
  • It is important to increase the sound proof performance of building for reducing the influence of aircraft noise on the bais of actual survey of existed buildings. The purpose of this study is to propose the basic data for designing sound insulation of residential house. In this study, field measurement of aircraft noise Interior and outside noise level difference were carried out for 7 days in 2 residential houses. As the result, aircraft noise levels showed to be Leq $71.8{\sim}74.5$dB(A), WECPNL $82.2{\sim}83.4$ and indoor noise level were NC-55 ${\sim}63$ over acceptable NC-30 in 2 measured houses. Noise reduction effect showed to be $15.8{\sim}23.1$dB(A) in measured houses, and houses with double window were preferable to those with single window in sound proof performance. The outside sound pressure level for residential house was a little different according to the type of source. In measuring by using aircraft noise it was effected by angle and distance from measuring point, to aircraft, window area, and sound absorption of room, and so on.

  • PDF

실내 충격소음 측정시스템 구현에 관한 연구 (A study of the measurement systems implementation for the interior impulse noise)

  • 송기혁;정성학
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권6호
    • /
    • pp.93-100
    • /
    • 2014
  • 본 연구의 목적은170dB 이상의 고충격 소음원에서 실내 충격소음을 측정 평가 할 수 있는 측정시스템 구축 방법을 제안하는데 있다. 이러한 목적을 달성하기 위하여 실내충격소음 측정시스템용 시험장을 설계 및 구현하고, 충격소음 측정용 마이크로폰, Head & Torso Simulator, Ear Simulator를 구성하였다. 충격소음 측정 시 정확한 측정을 위하여 3가지 측정방법을 동시에 측정할 수 있도록 구현하였으며, 정확성과 신뢰성을 위하여 3가지의 실내충격소음 측정값을 상호 비교하였다. 3가지 측정방법에 따른 최대 음압레벨과 옥타브 밴드 결과를 비교 분석함으로써 실내 충격소음의 주파수 특성에 따른 차이점을 확인하였다. 이러한 결과는 반사파의 영향에 의한 것으로 판단된다. 이에, 시험장의 크기를 변형하면서 측정할 수 있도록 실내 충격소음 측정시스템을 구현하였다. 본 시스템 구현을 통하여, 충격 소음원의 특징분석과 해당 주파수별 스펙트럼의 반사파 영향들을 파악할 수 있을 것이며, 향후, 실내 충격소음에 대한 데이터 획득 및 분석을 위하여 유용하게 활용될 수 있을 것으로 판단된다.

항공기소음피해지역 설정 기준의 개선방안에 관한 고찰 : 학교를 중심으로 (A Study on the Amendment of Criteria for the Establishment of the Area Damaged by the Aircraft Noise : Criteria for School Classrooms)

  • 이준호;이기호
    • 한국환경과학회지
    • /
    • 제18권3호
    • /
    • pp.263-269
    • /
    • 2009
  • The purpose of this study is to propose an appropriate criterium for proper sound insulation service preventing school classrooms from aircraft noise. The guideline of noise level for school facility by Korean school health law is less than Leq 55 which is less stringent than that of other countries. It has been reported that many students are annoyed and disturbed for their works when they are exposed to the noise level over Leq 55. It is desirable to modify this guideline of indoor noise level for school classroom. The noise level of classroom of which windows are opened was measured relatively high in case the school is located at the outside of the official area damaged by aircraft noise. In order to minimize the influence of aircraft noise on the school classrooms in the vicinity of domestic airport, it is necessary to improve the present criteria of WECPNL 75 for the establishment of the area damaged by aircraft noise from WECPNL 70.

에어컨 실내기의 방사소음과 실외기의 투과소음에 의한 환경소음 예측 (Environmental Noise Assessment of Indoor and Outdoor Units of Air-conditioner)

  • 장서일;최진권;손진희;모진용;구형모
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.40-47
    • /
    • 2003
  • This study was conducted to determine the sound paths and transmitted sound level in house. An air-conditioner system was selected a typical sound source. The measured transmission loss data shows that the apertures have an significant effect on the transmitted noise and comparable with the existing theoretical data. Therefore the complex aperture was substitute to quantitative apertures approximately. An effective simulation method, ray tracing and mirror image source method, was employed in the prediction of transmitted sound level. The measured results were efficiently reflected on the simulated results. So it is important that measuring the acoustic parameter prior to the prediction of the transmitted sound level in the house.

저소음 목재용 회전톱날의 개발에 관한 연구 (A Study of Developing the Low Noise Circular Saw Blade)

  • 강석춘
    • 한국정밀공학회지
    • /
    • 제17권7호
    • /
    • pp.147-155
    • /
    • 2000
  • To reduce the noise from wood cutting saw at the saw mill(lumber mill) or a construction area, some multi-layer sandwich saw blades which a aluminum or copper plate was inserted between the two steel plates were developed and were tested of the wood cutting noise level at various test places. From the research, it was found that the multi-layer saw blade with copper or aluminum plate between steel plates and spot welded 60 points could reduce the wood cutting sound level about 8.3 dB(97.031 dB - 88.743 dB) at indoor test and 3.8 dB(84.805 - 81.638 dB) at field test.

  • PDF

공기조화 취출구 소음 평가를 위한 물리지수 분석 (Analysis of Physical Parameters for the Evaluation of HVAC Diffuser Noise)

  • 박현구;김항;고성석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.402-405
    • /
    • 2006
  • The diffuser noise of HVAC(heating ventilating and air-conditioning) uses dB(A) or NC as a indoor noise criteria that ASHRAE represents, and there is no specific guide line for application. According to the previous study, there are some problems like that even though the sound level of sound source is same, the NC shows different values, which makes the noise rating confused. This problem is caused by the frequency characteristics of sound source and its sound level. Therefore, appropriate evaluation method should be considered based on the subjective responses. This study aims to analyze the physical parameters appropriate for the evaluation of HVAC diffuser noise. To achieve this, recording of sound sources, calculation of physical parameters and psycho-acoustic experiment were carried out and the results were derived from the correlation analysis between physical parameters and subjective evaluatio

  • PDF

청감실험을 통한 고화질 TV set 소음평가에 관한 실험적 연구 (An Experimental Study on the noise Rating of H.D. TV sets by Psycho-acoustic Experiments)

  • 이주엽;박현구;이태강;김희진;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.862-869
    • /
    • 2006
  • The purpose of this study is to propose the proper vocabularies for evaluating H.D TV set fan noise in residential condition. To achieve this goal, psycho-acoustic experiments were carried out with TV set fan noise modulated at specific frequency band. finally, a correlation analysis between vocabularies, and a factor analysis of psycho-acoustical responses were conducted. As a result of this study, followings are suggested. Analyzing the psycho-acoustical response corresponding to the various sound level, the higher the sound levels, the higher the response values were. It is estimated that the sound level determined psycho-acoustical responses. On the degree of response to fan noise, the initial level of negative feeling is located on $35{\sim}40$ dB(A). The factor of evaluating H.D. TV set fan noise has induced three the appropriate korean adjectives; Irritate, Monotonous, stuffy and dryness. The result of this study may be used to evaluate the acoustic threshold level for indoor noise or a basis for specifying the desired acoustic environment of dwellings.

  • PDF