Classification of Pollution Patterns in High School Classrooms using Disjoint Principal Component Analysis (분산주성분 분석을 이용한 고등학교교실 내 오염패턴분류에 관한 연구)

  • Jang, Choul-Soon;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.808-820
    • /
    • 2006
  • In regard to indoor air quality patterns, the government introduced various polices that were about managing and monitoring quality of indoor air as a major assignment, and also executed 'Indoor Air Quality Management Act' which was presented in the May, 2004. However, among the multi-usage facilities controlled by the Act, the school was not included yet. This study goal was to investigate PM 10 pollution patterns of the high school classrooms using a pattern recognition method based on cluster analysis and disjoint principal component analysis, and further to survey levels of inorganic elements in May, June, and September, 2004. A hierarchical clustering method was examined to obtain possible objects in pseudo homogeneous sample classes by transformation raw data and by applying various distance. Following the analysis, the disjoint principal component analysis was used to define homogeneous sample class after deleting outliers. Then three homogeneous Patterns were obtained as follows: the first class had been separated and objects in the class were considered to be sampled under semi-open condition. This class had high concentration of Ca, Fe, Mg, K, Al, and Na which are related with a soil and a chalk compounds. The second class was obtained in which objects were sampled while working air-conditioners and was identified low concentration of PM 10 and elements. Objects in the last class were assigned during rainy day. A chalk, soil element and various types of anthropogenic sources including combustions and industrial influenced the third class. This methodology was thought to be helpful enough to classify indoor air quality patterns and indoor environmental categories when controlling an indoor air quality.

Practitioners' Awareness of Planning Features for Environment-Friendly Apartment unit (공동주택 단위주거의 친환경 계획요소에 대한 전문가 의식조사)

  • Kwon, O-Jin;Lee, Yeun-Sook
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.11-18
    • /
    • 2003
  • The purpose of this study was to find out awareness of the environment-friendly planning elements for residential unit space among practitioners. The respondents in this questionnaire survey were 140 practitioners in architecture and interior design field. The major findings of this study were as follows; most of the respondents were aware of the impact of indoor built environment on residents' wellness. In addition, the survey respondents viewed that the factors for planning environment-friendly high-rise apartments were represented by gardening and energy-saving while their perception on the concept excluded comprehensive components affecting residents' life quality. Over 50% of respondents had an experience of applying environment-friendly planning elements in their works, and high frequency appeared on the general planning elements which had been applied special awareness as pro-environmental features. The respondents considered environment-friendly planning elements as important. Specially, space planning and system were considered more likely important in interior design field. In application of environment-friendly planning elements, cost, lack of consumers' awareness of and underdevelopment of environment-friendly materials were of concern. Therefore, the consumer's cognition needs to be improved for wide application about environment-friendly planning element, and then consumers are willing to pay additional construction cost of environment-friendly apartments. At the same time, the current practice that housing developers pass the additional cost on to residents needs to be changed. Then, the quality of life in high-rise residential settings can be improved. More importantly, the exchange and development of the reliable information on environment-friendly planning elements need to be made, and technical support and long-term policy for the development are required. This research showed current status of knowledge and practice in sustainable planning of unit apartment and proved basic information for future direction.

자연에너지와 건축조경계획

  • Jo, Gyun-Hyeong
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.22-29
    • /
    • 1993
  • Indoor thermal environment and energy consumption of buildings are preferentially affected by the microclimate around buildings. It is the first method to improve energy conservation effect of buildings and the ways to utilize natural energy for the comfortable residential environment that the difference between the microclimate condition and the indoor thermal condition is made in minimum as far as possible. There are many factors to control and minimize the difference, but landscape element is the major one among the factors. In this respect, the report analyzes landscape elements and their function to control microclimate and presents basic data for the desirable landscape planning mehtods to improve energy conservation effect of buildings and to attain the comfortable residential environment.

  • PDF

Trace Element Analysis and Source Assessment of Parking Lot Dust in Large Shopping Mall (대형유통업소주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Song, Hee-Bong;Ahn, Jeong-Eem;Jung, Yeoun-Wook;Yoon, Ho-Suk;Keum, Jong-Lok;Do, Hwa-Seok;Kim, Sun-Suk;Kim, Jong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.168-176
    • /
    • 2012
  • A total of 48 dust samples were collected from large shopping mall parking lots in Daegu metropolitan city in March 2011. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were affected by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were affected by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic trace element concentrations of ground roof dust were higher than those of ground and underground indoor dust. A large percentage of trace elements came from natural sources rather than anthropogenic sources. The percentage composition of chemicals of ground roof dust were higher than those of ground and underground indoor dust. This study showed that investigated parking lots were rarely contaminated with hazardous heavy metals. The heavy metal pollution of ground roof were higher than those of ground and underground indoors. The correlation analysis among trace elements suggest that components in ground roof were more highly correlated than those in ground and underground indoor. Also anthropogenic trace element levels were well correlated with parking lot age and parking density.

The Importance and Preference of Eco-Friendly Design Elements Related to Residential Space - Focused on the Residents in Gimhae - (주건공간 관련 친환경 디자인 요소의 중요도와 선호 - 김해지역 아파트 거주자를 대상으로 -)

  • Park, Jin-Kyoung;Oh, Chan-Ohk
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.1
    • /
    • pp.86-94
    • /
    • 2012
  • The purpose of this study was to examine the importance of eco-friendly design elements related to residential space by residents and what element they prefer. To achieve this, 18 eco-friendly design elements related to residential space were selected from the Green Building Certification Criteria and the relevant research papers. These elements were categorized into four areas; the ecological environment area (4 elements), the indoor environmental climate one (4 elements), the energy and resource saving one (6 ones), and the material one(4 ones). On the base of these 18 elements, the importance degree of each element was examined by using 5-point Likert scale. The subjects were 299 housewives living in apartment houses in Jangyu new town, Gimhae. The subjects perceived strongly the importance of eco-friendly design elements, but many of them did not know about Green Building Certification Criteria. Overall importance of 18 elements by the residents was very high. Also, the indoor environmental climate area was considered as the most important one, followed by the energy and resource saving area, the material area, and the ecological environment one.

  • PDF

A Study on the Residential Satisfaction of Indoor Environment of Urban Traditional House in Gyeongju (도시형한옥의 실내 환경에 대한 주거 만족도 분석)

  • Choi, Moo-Hyun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.3
    • /
    • pp.99-106
    • /
    • 2011
  • The purpose of this paper is to examine their degree of housing satisfaction in Gyeongju, focused on indoor environment of urban traditional houses. Mostly built during time period from 1930's to 1980's in Seoak-dong, Bomun-dong, Namsan-dong, Sajeong-dong, and Hwangnam-dong, Gyeongju' Hanok reveals the evolutionary development to fit into the urban settlement. Urban traditional house has important meaning as a type of residence maintaining tradition of Korean residential culture, and it is the study's first goal to derive developable element by analyzing the characteristics of urban traditional house focusing on such a feature. Residents in 5 districts in Gyeongju were classified and the self-administered questionnaires were provided to them. 187 papers were used for final analysis. The data for general trend of satisfaction was seek for after its average and standard variation were calculated.

Investigation of toxic organic solvent exposure in work places (작업장에서의 유해 유기용제 폭로에 관한 연구)

  • Jo, Young Min;Kang, Sang Wan;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.75-86
    • /
    • 2000
  • The purpose of this work was to document the conditions regarding organic solvent exposure to the workers in paint industry. Air concentrations of organic solvents were measured by passive personal samplers and analyzed by a gas chromatography. Urine samples for hippuric test were also taken from 330 workers who have worked at seven domestic factories for more than two years. Amongst 25 organic elements detected in the indoor environment of working places, toluene was the most common element, and methanol showed the highest mean concentration(18.2ppm). A few elements including methylethyl ketone and toluene partially exceeded the Korean Permissible Exposure Limit. A lack of environmental facilities such as exhaust ventilation, automatic cleaning system, and personal safety devices at present work plaus brings about various occupational diseases.

  • PDF

An Analysis on the Actual Condition of Indoor Air Quality in Rural House (농촌지역 노후주택의 실내공기환경 실태분석 연구)

  • Park, Roun;Cho, Sukyeong;Kim, Sangbum
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.9-17
    • /
    • 2020
  • The ratio of the deterioration housing in rural area was 29.6%, but it was 18.3% in urban area based on a 2018 survey. In consideration of the point, this study aims to analyze the actual condition of indoor air quality in rural houses to provide basic data for improving the indoor air environment. It was investigated 15housings of Hongseong-gun, Chungchengnam-do. To investigate the correlation between indoor air quality and housing type, both the field survey of housing type and precision diagnosis of concentration of indoor air pollutants such as HCHO, TVOC, Fine dust(PM-10, PM-2.5), CO2, Radon. The results of this study are as follows. First, according to the average value of each element of rural old housing, the construction year was distributed in 1939~2004, and 12households(80%) living in houses older than 30years have passed for about 46years. As for the housing area, more than 12houses(80%) of 60㎡ or more and 3 houses (20%) of less than 60㎡ were often living in relatively small-scale housing. Second, as a result of measuring indoor air pollutants in rural houses, substances exceeding the standard values were found in HCHO, TVOC, CO2. Third, in the case of Fine dust and Radon, none of such factors were exceeded the standard. Fourth, there was no significant difference in indoor air quality depending on housing type in rural houses. This paper is expected to contribute to the regional development projects and effective implementation of rural policies.

A Study on Lighting Environmental Evaluation of Senior Welfare Centers Based on biophilia

  • Yang, So Yeon;Lee, Tae Kyung
    • Architectural research
    • /
    • v.22 no.4
    • /
    • pp.123-133
    • /
    • 2020
  • Light is an essential environmental element for elderly people to do various activities. At senior welfare centers, healthy indoor lighting is especially necessary because the facilities are used by the elderly to perform their mostly indoor activities. The purpose of this study is to evaluate light environments at senior welfare centers for well-being lighting characteristics. We based the study on the 'Biophilia' theory, a concept related to health from happiness. Thus, this study is mainly based on literary review and survey research. For this, we conducted a location focused field study to identify the current state of the lighting environments at senior welfare centers in Busan, South Korea. First, we constructed structural questionnaire to evaluate lighting environment based on 'Light and Space' biophilia theory. Then, to survey subjective evaluation, the participant of research included total of 122 senior welfare center users. Based on the results of this research, the conclusions are as follows; 1) overall, it seems that the overall result of the light environmental evaluation seems to be high because the evaluated facilities in the case survey in large-scale were recently built elderly welfare centers. 2) most of the healing design elements are focused on the introduction of natural light and psychological influence. The satisfaction with actual natural light is evaluated to be high. Although shadow and reflected light are very important in discrimination and recognition of indoor space and wayfinding, the evaluation of reflected light and shadow was low for the study. 3) items that are related to the functionality of the light were highly evaluated, while the items that are related to the spatiality of the light were rated poorly. This study has its significance when examining the effects of light environments within the welfare center form of the perspective of senior citizens. It can be referenced when reconsidering the recognition of light environment as a major consideration factor to establish a desirable senior welfare center environment.

Optimization for the Humidification Performance of a Residential Rotor-Type Humidifying Element (가정용 로터식 가습 소자의 가습 성능 최적화)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.7-13
    • /
    • 2017
  • A comfortable indoor environment is important considering that many hours are spent in residential or office space. A humidifier is used to control the indoor humidity. In particular, an element type humidifier has the advantage of a simple structure and low energy consumption. Two types of humidifiers - stationary or rotor - are commonly used for residential purposes. In this study, performance optimization was conducted for a rotor-type humidifying element used in a residential humidifier. The optimization included the rotation speed, water submersion depth, etc. The test range consisted of an open area to the air from 57 to 90%, rotation speed from 0.2 to 2.0 rpm, frontal air velocity from 0.5 to 2.5 m/s. The results showed that the optimal open area to air was 70%. On the other hand, the effects of the rotation speed on the moisture transfer rate was negligible. On the other hand, the pressure drop increased with increasing rotation speed. As the frontal air velocity increased, both the moisture transfer rate and pressure drop increased. The humidification capacity of the present element was 0.08 ~ 0.31 kg/hr. A comparison of the data with the theoretical results was made.