Abstract
A comfortable indoor environment is important considering that many hours are spent in residential or office space. A humidifier is used to control the indoor humidity. In particular, an element type humidifier has the advantage of a simple structure and low energy consumption. Two types of humidifiers - stationary or rotor - are commonly used for residential purposes. In this study, performance optimization was conducted for a rotor-type humidifying element used in a residential humidifier. The optimization included the rotation speed, water submersion depth, etc. The test range consisted of an open area to the air from 57 to 90%, rotation speed from 0.2 to 2.0 rpm, frontal air velocity from 0.5 to 2.5 m/s. The results showed that the optimal open area to air was 70%. On the other hand, the effects of the rotation speed on the moisture transfer rate was negligible. On the other hand, the pressure drop increased with increasing rotation speed. As the frontal air velocity increased, both the moisture transfer rate and pressure drop increased. The humidification capacity of the present element was 0.08 ~ 0.31 kg/hr. A comparison of the data with the theoretical results was made.
Keywords
Rotor; Humidifying element; Optimization; Residential; Performance test;
Citations & Related Records
연도 인용수 순위
  • Reference
1 ASHRAE, Fundamantals, Ch. 8 Thermal Comfort, 1997.
2 I. H. Kim, K. Y. Kim, D. K. Kim, "Characteristics of bio-aerosol generation of household humidifiers by user practices", Environ. Health, vol. 38, pp. 503-509, 2012.
3 T. W. Kim, M. Kim, G. T. Kim, D. Y. Kim, B. Youn, D. K. Kim, Y. W. Han, "A theoretical study on the performance of humidification element," Proc. Summer Annual Conf., SAREK, pp. 163-166, 2015.
4 J. Wurm, D. Kosar, T. Clement, "Solid Desiccant Technology Review," Bulletin of IIR, No .2002-3, pp. 774-781, 2002.
5 A. A. Pesaran, T. R. Penny, A. W. Czandena, "Desiccant Cooling: State-of-the-Art Assessment," NREL Report (NREL-TP254-4147), 1992.
6 P. C. H. Yu, W. K. Chow, "A Discussion on Potentials of Saving Energy Use for Commercial Buildings in Hong Kong," Energy, vol. 32, pp. 83-94, 2007. DOI: https://doi.org/10.1016/j.energy.2006.03.019   DOI
7 ASHRAE Standard 41.1, Standard method for temperature measurement, ASHRAE, 1986.
8 ASHRAE Standard 41.2, Standard method for laboratory air-flow measurement, ASHRAE, 1986.
9 KARSE B 0050:2010, Indoor Humidifier.
10 ASHRAE Standard 41.5, Standard measurement guide, engineering analysis of experimental data, ASHRAE, 1986.
11 R. K. Shah, A. L. London, Laminar Flow in Ducts, Academic Press, 1989.