• 제목/요약/키워드: Indoor Environment

검색결과 2,581건 처리시간 0.045초

국내외 친환경건축물 인증제도 실내 환경 관련 부문 비교분석 및 개선안 연구 (A Study on the Comparative Analysis and Improvement of Indoor Environmental Factor in Green Building Rating Systems)

  • 조한
    • 한국실내디자인학회논문집
    • /
    • 제15권4호
    • /
    • pp.21-28
    • /
    • 2006
  • To promote environmentally responsible architectural practice, many nations have established their own green building rating system. Among other criteria, recently the indoor environmental quality section has been paid great attention due to Sick Building Syndrome, as this believed to caused by polluted indoor environment. In this context, indoor environmental quality is one of very important sections of each green building rating system and closely related to the very happiness of building users. The goal of this research is to compare and analyze the indoor environmental sections of three green building rating systems, GBCC, LEED v2.1, and BREEAM Office 2005, and find a direction for the improvement of GBCC. First, the three rating systems are analyzed in general to compare the importance of indoor environmental factors in each system. Second, the indoor environmental factors are reclassified within related sub-categories for the comparable analysis. Finally, based upon the comparable analysis, directions for the improvement of GBCC are as follows: 1. GBCC's h4r Environment Section needs to clarify its VOCs criteria based upon types of finish materials. 2. Sound Environment Section's noise control criteria needs to be revised based upon types of building usages and application method. 3. An indoor lighting related section needs to be included in GBCC, as even though light is the one of the most important factors in indoor environment, it has not been included in GBCC yet. 4. The sub-section of Confortable Indoor Environment Section related to the resting space and the universal accessibility are not in accord with the goal of green building rating system. These items need to be dealt within general building codes. 5. The rating evaluation structure and process need to be streamlined.

Relationship between Indoor and Outdoor Particulate Matter Concentrations in Japan

  • Nakai, Satoshi;Tamura, Kenji
    • Asian Journal of Atmospheric Environment
    • /
    • 제2권1호
    • /
    • pp.68-74
    • /
    • 2008
  • We briefly show the results of indoor and personal $PM_{2.5}$ measurements in an epidemiologic study designed to evaluate the health risks of ambient $PM_{2.5}$ in Japan and the relationship between indoor and outdoor PM concentrations. The impact of indoor and outdoor PM pollution on health is described based on one morbidity study. The results of other studies on indoor $PM_{2.5}$ measurements are also described.

거주자의 실내환경 관리행동에 교육 및 정보제공이 미치는 효과 (Changes of residents' indoor environment control behavior as a result of provided education and environmental information)

  • 배누리;최유림;전정윤
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.269-274
    • /
    • 2006
  • The purposes of this research are, first, to investigate the present condition of indoor thermal environment in winter. Second, to find out how residents' knowledge, consciousness, and behavior changed after provided with education and information of indoor climate. Finally, to reveal how this changes make alteration to their indoor environment. Thirty apartments were collected, and then divided into three groups as Control Group, Education Group, and Edu-information Group in order to conduct the purposes. Provided education and environmental information turn out to have a positive effect to residents' knowledge, consciousness, and behavior, and consequently, it leads residents to control their indoor environment more actively in some cases. Thus, it is important to provide residents with environmental education and information, and it should be conducted regularly in order to maximize the positive effect of education since it tends to decrease as time goes by.

  • PDF

전투근무지원정 격실의 실내 소음 분석 (Indoor Noise Analysis of Naval Combat Service Support Boat)

  • 박미유;한형석;조흥기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.91-96
    • /
    • 2011
  • The ship working environment of combat service support boat is very inferior to the ground working environment. For this reason, the crew of a combat service support boat suffer from an occupational disease such as hardness of hearing. Owing to its small size and low status, the improvement of its working and residential environment is occasionally ignored and its indoor noise was not fully investigated. In this study, for improving its residential environment indoor, the indoor noise of its shipboard compartments was analysed.

  • PDF

사물인터넷 기반 실내 환경 관제시스템 설계 및 구현 (Indoor Environment Monitoring and Controlling System design and implementation based on Internet of Things)

  • 박재운;김대식;주낙근
    • 한국정보통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.367-374
    • /
    • 2016
  • 오늘날 많은 사람들은 공동의 실내 공간에서 학업이나 업무 등의 다양한 일을 수행한다. 그러나 이렇게 함께 공동으로 사용하는 공간은 여러 가지 오염 요인에 의해 업무의 효율 뿐 만아니라 건강에도 좋지 않은 영향을 미치게 될 수 있다. 그래서 무엇보다도 공동으로 사용하는 공간에 대한 쾌적한 환경의 유지가 중요한 요소로 인식되고 있다. 본 논문에서는 이러한 공동으로 사용되는 사무실이나 도서관, 강의실 등의 공간을 보다 쾌적한 환경으로 만들기 위해서 환경적으로 유해한 요소들을 분석하고, 이러한 유해 요소들을 관리하여 보다 좋은 생활환경을 제공하기 위한 통합 실내 환경 관제시스템을 설계 구현한다. 제안된 실내 환경 관제시스템은 실내 환경의 상태를 실시간으로 모니터링 할 수 있고 액추에이터를 구동시킴으로써 쾌적한 환경을 제공할 것이다. 또한, 각종 실내 공간에 적용할 수 있을 뿐만아니라 사람들의 실내 환경오염 인지도 역시 높이는 방안이 될 것이다.

실내 공간별 미세먼지농도 비교 데이터의 시각화 (Visualization of the Comparison between Airborne Dust Concentration Data of Indoor Rooms on a Building Model)

  • 이상익;이진국
    • 한국주거학회논문집
    • /
    • 제26권4호
    • /
    • pp.55-62
    • /
    • 2015
  • The international concern on the inhalable fine dust is continuing to increase. In addition to the toxic properties of the fine dust itself, it can be more dangerous than other environmental factors since the dust pollution is hard to be detected by human sense. Although the information on outdoor air condition can be acquired easily, the indoor dust concentration is another problem because the indoor air condition is influenced by the architectural environment and human activity. It means occupants may be exposed to indoor dust pollution over a long period without being aware. Therefore the indoor dust concentration should be measured separately and visualized as an intuitive information. By visualizing, the indoor dust concentration in each space can be recognized practically in compare with the degree of pollution in adjacent spaces. Besides the visualization outcome can be used as base data for related research such as an analysis of the relation between indoor dust concentration and architectural environment. Meanwhile, with the development of network and micro sensing devices, it became possible to collect wide range of indoor environment data. In this regards, this paper suggests a system for visualization of indoor dust concentration and demonstrates it on an actual space.

국내 라돈 취약가구에 대한 주거공간의 실내 라돈 농도에 관한 연구 (A Study on Indoor Radon Concentration among Vulnerable Households in Korea)

  • 주덕현;박기호;정희원;임형준;복동석;윤동원;민경환;문경덕;김정운;이지민;최원용;김성윤
    • 한국환경보건학회지
    • /
    • 제41권2호
    • /
    • pp.61-70
    • /
    • 2015
  • Objectives: The purpose of this research was to examine radon exposure in terms of the relationship between the living environment and indoor radon concentrations among vulnerable households. Methods: Nationwide, 1,129 subjects were selected using personal questionnaires for adequately understanding the living environment, installation of E-PERM radon gas detectors, and investigation of the structure of the housing. Results: The mean concentration of indoor radon for all subjects was $130.2Bq/m^3$ (GM=101.7), and a total of 438 subjects (38.8%) exceeded the recommended standards ($148Bq/m^3$) for public facilities by the Ministry of the Environment. By location, the highest concentrations ($164.3Bq/m^3$, GM=124.1) were seen in North Chungcheong Province. In the case of the Seoul/Gyeonggi Province metropolitan area, they showed $125.6Bq/m^3$ (GM=105.1) and $118.9Bq/m^3$ (GM=96.5), respectively. By type of housing, indoor radon concentrations in single-family housing were higher than in row/multi-family housing (p<0.01). Although indoor radon concentrations raised in accordance with year of construction (p<0.05), the difference between indoor radon concentrations in underground residences was not observed to be statistically significant (p=0.633). Conclusion: More studies are necessary in the future regarding the difference in indoor radon concentrations that may occur due to different of types of indoor construction, building materials, and the amount of building materials.

휴대용 단말기의 근거리 무선통신을 이용한 실내 환경모니터링 시스템 (Indoor Environment Monitoring System Using Short-range Wireless Communication in Mobile Devices)

  • 예성현;한순희
    • 한국정보통신학회논문지
    • /
    • 제17권9호
    • /
    • pp.2167-2173
    • /
    • 2013
  • 최근 실내 공기오염으로부터 발생되는 많은 문제점에 대한 관심이 증가하고 있으며, 실내 환경정보를 측정하여 사용자에게 사전 조치를 취할 수 있는 시스템에 대한 필요성이 점차 증대되고 있다. 이와 관련하여 본 논문에서는 휴대용 단말기, 환경 센서를 이용하여 각종 실내 환경정보를 측정할 수 있는 근거리 무선통신을 이용한 실내 환경정보 모니터링 시스템을 설계하고 구현하였다. 제안하는 시스템은 사용자의 휴대 단말기로 센서노드가 설치되어 있는 실내 환경 정보를 사전 인지하고, 위험 요소가 인지될 경우 적절한 대비를 취할 수 있는 장점이 있다.

울산지역의 대기오염 환경의 차이가 거주자의 실내환경 평가 및 인식에 미치는 영향 (The Influence of Air Pollution Level on Resident's Evaluation and Cognition for Indoor Environment in Ulsan)

  • 유복희
    • 한국주거학회논문집
    • /
    • 제21권3호
    • /
    • pp.87-94
    • /
    • 2010
  • The aim of this study was to evaluate the influence of air pollution level in industrial and residential district of Ulsan on resident's evaluation and cognition for indoor environment. The evaluation of air pollution materials (as $SO_2$, $NO_2$, $O_3$, CO, PM10) were investigated to understand the distributional characteristics in survey area, and air quality monitoring data from 2007 to 2009 were used. The data was applied in a realtime measurement of industrial and residential area respected to difference of the pollution level in Ulsan. The questionnaire of this survey for resident's cognition was to find out characteristics on perception of indoor environment and outdoor air quality recognition based on the distinct characteristics of the areas. The results of this study shows that resident's satisfaction at clean level outdoor air and indoor environment were different whether it was residential area or industrial area and outdoor air pollution level has direct influence on resident's satisfaction in indoor environment.

교육시설 친환경 인증에서 실내 빛환경 항목 개선방안에 관한 연구 - G-SEED, LEED, BREEAM, CASBEE를 중심으로 - (A Study on the Improvement Method of Indoor Light Environment Items in Environmental Certification for Educational Facilities - Focusing on G-SEED, LEED, BREEAM, CASBEE -)

  • 이세원;이경선;김수란
    • 대한건축학회논문집:계획계
    • /
    • 제34권5호
    • /
    • pp.61-69
    • /
    • 2018
  • The goal of this study is to compare the evaluation results of indoor daylight environment for each certification and propose improvement points. As the importance of indoor daylight environment has increased, foreign countries have been aware of this and have changed the light environmental certification items. On the other hand, Korea environmental certification systems have not been able to follow the current situation. In order to improve this, this study intended to find evaluation criteria for each category by comparing and analyzing indoor daylight environment certification items in Korea's G-SEED, LEED in the United States, BREEAM in the UK, and CASBEE in Japan. After that, this study simulated 3D models of three spaces about classroom, reading room and club room of Yanghyun elementary School which is scheduled to be constructed for the evaluation of indoor daylight environment, and the results were analyzed to suggest for improvement.