• Title/Summary/Keyword: Indoor Comfort

Search Result 355, Processing Time 0.022 seconds

Indoor Environment Due to Multi-cultural Complex Space Structure Impact on the Choice of Guests (복합 문화공간 구조에 따른 실내환경이 이용객의 선택에 미치는 영향)

  • Kang, Jin-Young;Won, Young-Suk;Cha, Jung-Hoon;Kim, Su-Min
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.4
    • /
    • pp.278-286
    • /
    • 2011
  • Today, people are becoming more conscious regarding environmental-friendliness, and the society as a whole is becoming more aware of it. With such phenomenon, the purpose of this research is to examine how comfort and pleasantness of indoor environment influences when selecting a place for multi-cultural complex. To demonstrate the stated hypothesis, I have preceded the experiment by selecting the C multi-cultural complex of closed-type structure and T multi-cultural complex of open-type structure. The next step I took, in order to validate the public's awareness of environmental-friendliness, was conducting a survey. I then deducted a conclusion through comparison and analysis of experiment measures with survey result. As a result of the research, the experiment measures of each air, light, heat condition of the T multi-cultural complex of open-type structure had a higher measurement for the comfort and pleasantness than the C multi-cultural complex of closed-type structure. Moreover, after validating the consciousness of the public through the survey, they had a tendency preferring T multi-cultural complex of open-type structure over C multi-cultural complex of closed-type structure in terms of comfort and pleasantness. To summarize, it is proper to conclude that the criteria - comfort and pleasantness of indoor environment - has influenced significantly when it comes to selecting a multi-cultural complex through both the experiment and the survey result.

  • PDF

A Seasonal Indoor Thermal Conditions of a Newly-launched Training Ship

  • Hwang, Kwang-Il;Shin, Dong-Keol;Lee, Jin-Uk;Lee, Sang-Il
    • Journal of Navigation and Port Research
    • /
    • v.33 no.4
    • /
    • pp.289-294
    • /
    • 2009
  • The living performances of crews and passengers in cabins have been less received attention, while Korea is a top leading country in ship building industry. To develop a high value added ships like 5-star cruisers, researches on the comfort and productivity in cabins should be carried out with urgent. The purpose of this study is to measure and analyze of the ship's indoor thermal conditions in spring, summer and winter, and also to compare the seasonal differences, of which conditions are supplied from and controlled by marine HVAC The temperature, humidity and air supply volume of 5 different needs of cabins on a training ship were measured through a year, which was launched at Dec. 2005 and totally 246 crews can go on board for education. The following results were obtained: (1)In the spring, the temperature in cabins was measured as $20{\sim}25^{\circ}C$ and humidity was below 30%. (2)In the summer, the temperatures was controlled at $21{\sim}27^{\circ}C$ in almost cabins and humidity was between $40{\sim}60%$ which is known as comfort conditions. (3)In the winter, temperature and humidity was maintained between $19{\sim}26^{\circ}C$, and humidity was between $10{\sim}50%$. (4)It is clear that the humidity conditions in cabins are not properly controlled at all through a year to satisfy the Comfort Standards provided by ASHRAE and/or ISO, In conclusion, humidification and dehumidification of cabins must be treated with importance for more comfort living and working environments for crews and passengers.

Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements (PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계)

  • Sung, Jae-Yong;An, Kwang-Hyup;Lee, Gi-Seop;Choi, Ho-Seon;Lee, In-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.

Analyzing the Change of Indoor Thermal Environment with the Introduction of the Water Space in Exterior Housing (주거 외부 수공간 도입에 따른 실내 온열 환경 변화 분석)

  • Oh, Sang-Mok;Oh, Se-Gyu;Won, Hyun-Seong
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.41-48
    • /
    • 2010
  • This study shows how the water space outside the housing impacts the indoor thermal environment. CFD simulation was used for this experiment to analyze the interior environment focusing on the effect of temperature control and the thermal comfort. A shape of perfect square, which creates the very basic space formation, was used and the simulation was processed looking at the size, distance, and the location of the water space. The results of the experiment are as follows. Firstly, introducing a water space with the same floor area size of the simulation model decreased the indoor temperature by 1 Celsius (3.72%). It was determined the interior environment was considered as a comfort zone when the water space was greater than 70% of the floor area. Secondly, there was not much influence to the level of thermal comfort of the interior environment when the distance to the water space from the housing was greater than 2 meters. Lastly, interpreting the location of water space, the effect of controlling the total areas' temperature was the greatest following with the surrounding of the formation. There barely was any change to the temperature considering the side and the rear of the area.

A Measurement and Evaluation on the Indoor Thermal Conditions in Spring of a New Training ship (신조 운항실습선의 봄철 실내 온열환경 실측평가)

  • Shin, Dong-Keol;Lee, Jin-Uk;Lee, Hyong-Ki;Park, Youn-Cheol;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.939-946
    • /
    • 2007
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those, supplied and controlled by ship's HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured on a newly-launched training ship during 2nd through 5th of April, 2007. Followings are the results of this study. (1)Because only partial loads are needed in spring season, the air volume from diffusers are measured as below 20%. (2)The temperatures are ranged between $20{\sim}25^{\circ}C$ and those are within comfort temperature range proposed by AHREA. (3)But humidities in cabins are very low and it could be the reason of a cold and/or a skin disease. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of low humidity, only 16.1% among the measured data are satisfied with the comfort standard range proposed by ASHREA. To improve the predictability and the comfort, HVAC should maintain the humidity as $40{\sim}60%$.

Optimization of Wind Louver Angle By CFD Simulation

  • Piao, Gensong;Shon, Donghwa;Kim, Youngwoo;Lee, Jungwon;Choi, Jaepil
    • Architectural research
    • /
    • v.18 no.4
    • /
    • pp.137-144
    • /
    • 2016
  • The objective of this study was to determine the optimal angle of a wind louver that would induce the optimal wind speed for indoor. Being controlled to have an optimized angle depending on the direction from which wind is blowing and the wind speed, the wind louver to be installed on the building envelop comes to create indoor comfort through a constant wind speed using the function that reduces the indoor wind speed by changing the angle when the wind speed is not lower than a certain level and makes wind flow into the room to the maximum when the wind direction is adverse to catching the wind or the wind speed is not higher than a certain level. To determine the optimal wind louver angle, a core-centered office building with cross-ventilation problems in the climate of Seoul, Korea, which experiences four distinct seasons, was considered for analysis in this study. A module 1 office space model was used for the CFD simulation to analyze the average indoor wind speed with respect to the outdoor wind speed (varied between 1 and 8 m/s), the wind louver angle, and the outdoor wind direction (varied between $0^{\circ}$ and $180^{\circ}$ in steps of $10^{\circ}$).

A Study on the Estimate of Thermal Environment and the Subjective Responses of the Aged during Summer in the Welfare Facilities -Focused on the Welfare Facilities for the Aged in Taegu- (노인복지시설의 하절기 실내 온열환경과 노인의 주관적 반응평가에 관한 연구 -대구광역시 소재 노인복지시설을 중심으로)

  • 이형우;홍원화
    • Journal of the Korean housing association
    • /
    • v.13 no.2
    • /
    • pp.23-29
    • /
    • 2002
  • The purpose of this study was to find out the present condition of indoor thermal environment and to investigate the environmental needs of the elderly through the measurement of outdoor and indoor physical thermal environment elements and the questionary survey of the response to thermal environment in two welfare facilities for the aged in Taegu during summer in 2001. The 38 residents among the total of 134 residents were asked to record their feelings. The result of this study was as follows. The indoor thermal environment in the facilities subjected leer this study was seemed to be comfortable comparatively. But the values of mean indoor temperature measured were about 1.6-1.8$^{\circ}C$ higher than that of a existing domestic research suggested as thermal comfort zones for the elderly during summer, and most residents fe1t somewhat hot in inner space. And the value of indoor relative humidity in one facility was out from the range of comfort humidity(40-70%). Also there were differences by the geographical location between the two.

An Analysis of Performance Assessment Factors of Indoor Environmental Quality in Multi-Family Housing Using Post Occupancy Evaluation (거주후 평가를 통한 공동주택의 실내환경 성능평가요소 분석에 관한 연구)

  • Lee, Si-Nae;Park, Jin-Chul;Rhee, Eon-Ku
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.128-134
    • /
    • 2011
  • The objective of this study is to analyze the major factors of indoor environment that affect the satisfaction of the occupancy in multi-family residential buildings. The results of this study can contribute to improving the comfort of the residents effectively as they are applied preferentially at the design and construction stages. The indoor environment factors investigated for the analysis included thermal, light, air and the acoustic environment. The individual factors were derived from the 'indoor environment' assessment indices of the green building certificate systems of various countries. Based on these, a questionnaire was prepared to conduct the Post Occupancy Evaluation. The survey results were statistically analyzed.

Development of an IAQ Index for Indoor Garden Based IoT Applications for Residents' Health Management (실내거주자 건강 관리를 위한 IoT기반 실내정원용 IAQ지수 개발)

  • Lee, Jeong-Hun;An, Sun-Min;Kwak, Min-Jung;Kim, Kwang Jin;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.421-432
    • /
    • 2018
  • Objectives: In this study, we started to develop an indoor garden integrated IoT solution based on IAQ (indoor air quality) and interconnection with an environmental database for smart management of indoor gardens. The purpose of this study was to develop and apply an integrated solution for customized air purification from an indoor garden through big data analysis using IoT technology. Methods: An IoT-based IAQ monitoring system was established in three households within a new apartment building. Based on real-time and long-term data collected, $PM_{2.5}$, $CO_2$, temperature, and humidity changes were compared to those of indoor garden applications and the analyzed results were indexed. Results As a result of the installation, all three households had no results exceeding the standard for indoor air pollution on average $PM_{2.5}$ and $CO_2$ indices. In the case of indoor garden installation, the IAQ index increased to the "Good" section after the installation, and readings in the "Bad" section shown before the installation disappeared. The comfort index also did not dip into the "Uncomfortable" section, where it had been preinstallation, and significantly lowered the average score from "Uncomfortable for sensitive groups" to "Good". Overall, the IAQ composite index for the generation of installations decreased the "Good" interval, but "Bad" did not appear. Conclusions In this study on developing an integrated solution for IAQ based on IoT indoor gardens, big data was analyzed to determine IAQ and comfort indexes and an IAQ composite index. Through this process, it became understood that it is necessary to monitor IAQ based on IoT.

A NUMERICAL INVESTIGATION OF INDOOR AIR QUALITY WITH CFD

  • Sin Vai Kuong;Sun Ho I
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.87-93
    • /
    • 2005
  • Macao, a city with three sides bounded by water, is hot and humid in weather in more than six months of a year. This uncomfortable weather induces the frequency of operating air-conditioners. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In the paper, investigation of distribution on carbon dioxide, room air temperature and velocity, as well as air diffusion performance index (ADPI) of a single bedroom in Macao is studied by using the computational fluid dynamics (CFD) software FLOVENT 3.2. Simulations of locating the air-conditioner at 4 different walls will be done and comparisons and analyses of the results will be performed to decide a proper location for the air-conditioner for obtaining good thermal comfort.