Analysis of Indoor Temperature and Humidity Changes with the Operation of the Condense Drying Dehumidifier (가정용 제습기의 운전에 따른 실내 온습도 변화 분석)

  • Choi, Younhee;Song, Doosam;Sohn, Won-Woo;Lim, Younghoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.12
    • /
    • pp.626-632
    • /
    • 2015
  • The purpose of this paper is to analyze the indoor temperature and humidity changes with the operation of a condense drying humidifier. This paper illustrates the principles and composition of a condense drying dehumidifier, which is broadly used in Korean households. Experiments were conducted repeatedly on rainy days in a test chamber. The results showed that the indoor RH was lowered to 40% within 2 hours while the indoor temperature was increased by approximately $4.3^{\circ}C$ with the operation of the humidifier.

A Study of Indoor Thermal and Air Quality in Middle and High School Classrooms during Winter (겨울철 학교교실의 실내열.공기환경 실태와 학생들의 주관적 반응)

  • Choi, Yoon-Jung;Na, Sun-Hee;Jo, Su-Youn
    • Korean Journal of Human Ecology
    • /
    • v.18 no.2
    • /
    • pp.509-522
    • /
    • 2009
  • This is a basic study to improve air quality of school classrooms in winter time. The purposes are to check indoor thermal and air environment in school classrooms during winter and to analyze influencing factors on indoor environment. The measurements of students' physical elements with questionnaire surveys were carried out in a total of 6 classrooms. As a result, this research shows that the temperature of one classroom was below indoor thermal standard level, three classrooms had lack of heat, and two classrooms are heated much, which induce relatively low humidity. All of 6 classrooms had lack of ventilation, being high level of $CO_2$ concentration and 2 classrooms are in condition of high PM10 concentration. The majority of students(76%) answered that the cause of their 'heated space syndrome' is because of the lack of ventilation. Students' opening windows for ventilations is hardly carried out at normal times, except that indoor temperature is over standard. That is, we can suggest one of solutions, which is to enable students to operate heating and ventilating system by themselves according to students' physical condition.

Development of an Integrated Multizone Model for Indoor Air Environment Prediction (실내공기환경 예측을 위한 통합 다구획 모델의 개발)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.17 no.9
    • /
    • pp.993-1003
    • /
    • 2008
  • Interior space in most buildings is divided into several zones. The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. An integrated multizone model to predict these environmental factors simultaneously was developed. Also, a computer program for this model was written by the language of VISUAL BASIC. The proposed model was applied to a apartment with five rooms that had been tested by Chung. Comparison of predicted results by this study with measured results by Chung showed that their variations were within 14% for airflow rates, 1% for temperatures, 12% for humidities, and 5% for concentrations. It was seen that the opening operation schedule of building has a significant effect on the air moisture md contaminant removal. Thus, this model may be available for predicting the indoor air environment and may be contributed to design the ventilation plan for controling of indoor air quality.

Estimation of Source Emission Rate on Volatile Organic Compounds and Formaldehyde Using Indoor Air Quality Modeling in New Apartment (실내공기질 모델을 이용한 신축공동주택의 VOCs 및 HCHO 배출량 추정)

  • Sim, Sang-Hyo;Kim, Yoon-Shin;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.10
    • /
    • pp.929-933
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time Indoors. Especially when indoor environments have sources of contaminants, exposure to in-door air can potentially pose a greater threat than exposure to ambient air. In this study, estimations of volatile organic compounds and formaldehyde omission rate in indoor environments of new apartments were carried out using mass balance model in indoor environment, because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. Considering the estimated emission rate of volatile organic compounds and formaldehyde, it Is suggested that new apartment should be designed and constructed in the aspect of using construction materials to emit low hazardous air pollutants.

A Study on the Indoor Air Pollution of Singing Room and PC Room (노래방과 컴퓨터 게임방 내의 실내공기오염에 관한 연구)

  • 이주상;원정일;이철민;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.67-74
    • /
    • 2002
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. Since most people spend a large majority of their time indoors, indoor air may affect human health more than outdoor air. This outline survey was carried out to investigate the extent of indoor air pollution in singing room and PC room. The concentrations of major indoor air pollutants(carbon dioxide, total suspended particulate, airborne microbes) and Thermocircumstance(temperature, relative humidity, intensity of illumination) were observed from October 1 to 31, 2001. As results of the survey, the mom values of thermocircumstance in singing room and PC room were $22.1^{\circ}C$ of temperature, 37.1% of humidity, 75 Lux of intensity of illumination and $22.0^{\circ}C$ of temperature, 52.6% of humidity, 135 Lux of intensity of illumination, respectively. The mean concentrations of carbon dioxide were 1589 ppm in singing room and 615 ppm in PC room, respectively The concentrations of carbon dioxide in singing room were higher than the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs. The mean concentrations of total suspended particulate were $0.33{\;}mg/\textrm{m}^3$ in singing room and $0.57{\;}mg/\textrm{m}^3$ in PC room respectively. The mean concentrations of airborne microbe were $16{\;}CFU/\textrm{m}^3$ in singing room and $12{\;}CFU/\textrm{m}^3$ in PC room, respectively.

The Indoor Thermal and Air Environment during Winter in One-room Type Multi-family Houses Occupied by University Students (대학생 거주 원룸형 다가구주택의 겨울철 실내열공기환경 실태)

  • Choi, Yoon-Jung;Kim, Wn-Hak
    • Korean Journal of Human Ecology
    • /
    • v.19 no.4
    • /
    • pp.745-760
    • /
    • 2010
  • The purposes of this study were to investigate the state of indoor thermal and air environment during winter in the one-room type multi-family houses occupied by university students and to analyze factors which influenced this environment. Field survey was conducted in 10 houses between 30th January, 2009 and 13th February, 2009 which measured indoor thermal and air elements as well kept records of interviews with residents and other related factors. Measured elements were air temperature, relative humidity, as well as concentrations of $CO_2$, CO, TVOC, and PM-10. The results can be summarized as follows. 1) The mean air temperature in each house ranged from 19.3 to $25.3^{\circ}C$, so most houses were not suitable for evaluation criteria($20-22^{\circ}C$). The average $CO_2$ concentration in each house was 965~3259ppm, so most houses exceeded evaluation criteria(1000ppm). The average TVOC concentration in each house were 0.00~1.17ppm, 5 houses exceeded evaluation criteria(0.12ppm). 2) Relative humidity, CO concentration, and PM-10 concentration were suitable for evaluation criteria. Therefore, indoor thermal and air environment during winter in one-room type multi-family housing occupied by university students was found to be generally uncomfortable. Important factor which were found to influence air temperature and the concentration of $CO_2$ were smaller space capacity than general house. Other factors which were found to influence the environment of these houses were the existence of a balcony as well as factors relating to the behavior of occupants such whether or not heating were operated, whether windows were opened, whether fans used, whether occupants smoked or used cosmetics, and whether the space was dusted.

Present Condition of Indoor Thermal and Air Environment by Cooling in School Classrooms (학교교실의 냉방시 실내열.공기환경 실태)

  • Choi, Yoon-Jung;Jeong, Youn-Hong;Lee, Seon-A;Kim, Hye-Kyeong;Hwang, Jin-A
    • Journal of the Korean housing association
    • /
    • v.18 no.4
    • /
    • pp.49-58
    • /
    • 2007
  • The purpose of this study were to make clear the present condition of indoor thermal and air environment by cooling in school classrooms and to analyze the relation of the living conditions with indoor environment. The measurements on physical elements and observations on living conditions were carried out in 6 classrooms of 3 middle or high schools. Measuring elements were indoor temperature, relative humidity, PM10 and $CO_2$ concentration. As results, the averages of indoor temperature each classrooms were $24.9{\sim}26.6^{\circ}C$. Most of classrooms were lower than the Maintenance standard $(26{\sim}28^{\circ}C)$ of School Health Law. The means of relative humidity were $51.3{\sim}72%$, all classrooms were ranged within the standard $(30{\sim}80%)$. The means of PM10 concentration were $3.5{\sim}23.1{\mu}g/m^3$, all classrooms were kept within the standard $(100{\mu}g/m^3)$. The means of $CO_2$ concentration were $1218.7{\sim}4705.4ppm$, all classrooms were exceed the standard (1,000ppm). The results of analysis on relations of living conditions with the physical elements are as follow; the air conditioner set of temperature, windows and doors opening elapsed time, the number of students in classrooms and activities of students had certain effect on indoor environment.

Control of Compressor and Electronic Expansion Valve for a Tandom-type Air-conditioner (텐덤형 냉방시스템의 압축기와 전자팽창밸브 제어)

  • Jung, Nam-Chul;Han, Do-Young
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.469-473
    • /
    • 2005
  • Capacities of a tandom-type air-conditioner may be modulated by turning on/off multiple compressors and adjusting positions of a electronic expansion valve. In this study. control algorithms for compressors and a electronic expansion valve were developed by using fuzzy’ logics. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature.

  • PDF

Control of Compressors and Electronic Expansion Valve considering the Safe Operation of a Tandem-type Air-conditioning system (텐덤형 냉방시스템의 안전운전을 고려한 압축기와 전자팽창밸브 제어)

  • Han, Do-Young;Kim, Jae-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.675-680
    • /
    • 2006
  • Capacities of a tandem-type air-conditioner may be modulated by turning on and off of multiple compressors, and adjusting the position of a electronic expansion valve. In this study, control algorithms for compressors and a electronic expansion valve were developed by using fuzzy logics. The pressure control algorithm was also developed for the safe operation of compressors. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature,

  • PDF

A Study of Thermal, Air-flow and Humidity Conditions in an Indoor Swimming Pool (실내수영장의 열, 기류 및 습도환경에 관한 연구)

  • 강석윤;이태구;문종선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.683-689
    • /
    • 2003
  • The thermal comfort of an indoor swimming pool is different from that of general indoor space because of the characteristics of large space and the wear conditions of swimmers. Dew condensation by humid air not only makes mold on the floor, wall and roof but also decreases the durability of buildings by penetrating into their structures. In this study, the characteristics of the flow field, the temperature field and the humidity distribution in an indoor swimming pool have been examined by the numerical method to estimate the level of thermal comfort and the generation rate of dew condensation. The results showed that the dew condensation regions were spread widely at the eastern parts of the swimming pool due to the insufficient air flow rate with low velocity and temperature. To prevent the generation of dew condensation in a region, a sufficient warm air flow rate should be supplied to make an air mixing. The values of PMV at horizontal plane of 1.5 m height have the range of -1.0∼1.2, which means the suitable level for swimmers.