Abstract
Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time Indoors. Especially when indoor environments have sources of contaminants, exposure to in-door air can potentially pose a greater threat than exposure to ambient air. In this study, estimations of volatile organic compounds and formaldehyde omission rate in indoor environments of new apartments were carried out using mass balance model in indoor environment, because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. Considering the estimated emission rate of volatile organic compounds and formaldehyde, it Is suggested that new apartment should be designed and constructed in the aspect of using construction materials to emit low hazardous air pollutants.
Keywords
Emission rate; Indoor air duality; VOCs; HCHO; Ventilation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kraenzmer, M., 1999, Modeling and continuous monitoring of indoor air pollutants for identification of sources and sinks, Environment International, 25(5), 541-551   DOI   ScienceOn
2 Hoddinott, K. B. and A. P. Lee, 2000, The use of environmental risk assessment methodologies for an indoor air quality investigation, Chemosphere, 41, 77-84   DOI   ScienceOn
3 통계청, 1999, 생활시간조사보고서, 생활시간량편, 통계청, 1, 29-50
4 Skillas, G., C. H. Huglin and H. C. Siegmann, 1999, Determination of air exchange rates of rooms and deposition factors for fine partides by means of photoelectric aerosol sensors, Indoor Built Environment, 8, 246-254   DOI   ScienceOn
5 Jones, A. P., 1999, Indoor air quality and health, Atmospheric Environment, 33, 4536-4564
6 Cyrys, J., J. Heinrich, K. Richter, G. Wolke and H. E. Wichmann, 2000, Sources and concentrations of indoor nitrogen dioxide in Hamburg and Erfurt, The Science of the Total Environment, 250, 51-62   DOI   ScienceOn
7 환경부, 2004, 실내공기질공정시험방법, 환경부, 34-51
8 양원호, 배현주, 이기영, 정문호, 2000, 측정시간에 따른 거주지역 환기량 계산 오류에 관한 연구, 한국환경위생학회지, 26(3), 50-54
9 Yang, W., K. Lee and M. Chung, 2004, Characterization of Indoor Air Quality Using Multiple Measurements of Nitrogen Dioxide, Indoor Air, 14, 105-111   DOI   ScienceOn