Analysis on Characteristics and Related Factors of Indoor Air Quality in Newly Built Wooden Houses (신축목조주택의 실내공기질 특성 및 관련요인 분석)

  • Choi, Yoon-Jung;Lee, Jae-Kyung;Cha, Ye-Rang
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.23-32
    • /
    • 2015
  • The purpose of this research is to analyze characteristics and related factors of IAQ (Indoor Air Quality) in newly built wooden houses by measuring pre and post occupancy. The subjects were five wooden houses which were built with similar materials and completed from July to December 2013. Measuring factors were TVOC, HCHO, PM10, $CO_2$, CO, indoor temperature, and relative humidity. As the result of pre occupancy measuring, the houses that revealed the lowest TVOC concentration or HCHO concentration were satisfied with "the standard for newly built apartment houses". Therefore, IAQ by the wooden structures is considered to be in good condition. However, in cases of partial value exceeded the standard, the reason is analyzed to be the materials of molding, wrapping doors, built-in closet, or kitchen furniture, etc. rather than structure materials. Most PM10 concentration level showed slightly below "the standard for occupied multi-use facilities". Remaining of construction dust was considered to be the reason. As the result of post occupancy measuring, every value except of one subject's TVOC concentration was lower than pre occupancy, explaining the importance of natural ventilation.

A Study on the Dew Condensation According to the Operational Conditions of a Heat-Recovery Ventilator (전열교환 환기시스템의 운전 상태에 따른 결로 발생에 관한 연구)

  • Jeon, Byung-Heon;Kim, Jong-Won;Lee, Seung-Kap;Lee, Young-Ju;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.10
    • /
    • pp.529-533
    • /
    • 2013
  • Heat-recovery ventilators are being adopted in most newly built apartment houses for energy reduction and indoor environment improvement. In winter, however, the dew condensation resulting from the difference between the indoor and outdoor temperatures may reduce the ventilator's performance and threaten the health of indoor residents. This study analyzes the occurrence of dew condensation according to the ventilator's operational conditions and the changes of temperature and products. The experimental results show that condensations is formed at $26^{\circ}C$ and 60%R.H, which is an unfavorable climatic condition, and when the damper is not closed tightly. Therefore it is important to ensure damper performance to prevent back flow.

Experimental Study on Cooling and Heating Operation Characteristics of Inverter type Multi-Heat Pump (인버터형 멀티 히트펌프의 냉난방 운전특성에 대한 실험연구)

  • Park, B.K.;Seo, D.N.;Um, Y.S.;Kwon, Y.C.;Ko, K.W.
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.618-622
    • /
    • 2007
  • In the present study, the cooling and heating operation characteristics of a multi-heat pump have been experimentally investigated for the number of the indoor units(A, B, C) and the operating conditions. The heat pump was controlled by an inverter scroll compressor. The performance of the heat pump was measured by the multi-calorimeter of an air enthalpy method. Cooling and heating capacities and COPs were obtained at the cooling and heating temperature conditions and the setting temperatures of an indoor unit. With increasing the operation frequency of the compressor, the cooling and heating capacities of the heat pump increased linearly. The operation frequency region of the compressor was different as the combination of the indoor unit and the cooling/ heating condition.

  • PDF

Study on Application of Shaft Box type Balcony for Improvement of Ventilation Performance in Apartment (공동주택의 환기성능 개선을 위한 Shaft Box형 발코니의 적용성 검토)

  • Roh, Ji-Woong;Kim, Gon
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, because of the continuous rise of international oil price, energy saving is strongly demanding. So, Ecological technics of architecture such as use of natural energy have been actively explored in the field of building. In the method of utilizing natural energy, the key point is to saving energy effectively as not lowering the comfort of indoor environment, various systems investigated. Many papers about double skin facade system have been reported, it is announced broadly that the system is very effective in improvement of natural ventilation and indoor thermal environment, and also protecting outdoor sound. The shaft box facade is a special form of box window construction. It consists of a system of box windows with continuous vertical shafts that extend over a number of stories to create a stack effect. The facade layout consists of an alternation of box windows and vertical shaft segments. This research investigated the natural ventilation performance of shaft box type balcony which conform the shaft box type double skin to the exiting balcony construction. First, analyzed various types of exiting apartments, proto-type was decided. By using virtual environment Program, modeling the proto-type, compared the contribution of air temperature and the effect of outdoor air cooling. by this research, we confirmed that shaft box type balcony had many possibility for improvement of indoor environment.

Analyses of the current market trend and research status of indoor air quality control to develop an electrostatic force-based dust control technique (정전기적 힘을 이용한 실내공기 미세부유먼지 제거 요소기술의 개발을 위한 기술별 시장현황 및 연구 동향 분석)

  • Yoon, Young H.;Joo, Jin-Chul;Ahn, Ho-Sang;Nam, Sook-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6610-6617
    • /
    • 2013
  • This study examined the current and future Indoor Air Quality (IAQ) control device markets and analyzed the recent studies on indoor air pollutantr emoval to develop a new technology for fine dust control. Currently, the mechanical filter technique occupies the bulk of the IAQ control market but the electronic technique is emerging as an alternative to control fine dust efficiently. Among the gaseous VOCs and fine dust particles contaminating the indoor air quality, fine dust particles are more problematic because they threaten human health by penetrating deep into the body and producing secondary contaminants by chemical reaction with VOCs. The electronic IAQ control device using dielectrophoretic and electrostatic forces is a good option for public spaces where many people pass, and at the same time, it needs to consider temperature, humidity, and the particle properties of specific areas to highlight the control efficiency. Electronic-related technology is expected to be used widely in many public/private spaces wherever a dust-free environment is required.

The Assessment and Recognition on Indoor Air Quality at Schools in Korea (전국 일부 학교 건축물 내의 실내 공기 및 인식도 조사)

  • Sohn Jong-Ryeul;Yoon Seung-Uk;Kim Jong-Hyuk;Lee Yong-Sik;Choi Han-Young;Kim Young-Sung;Son Bu-Soon;Yang Won-Ho;Kim Min-Hoi
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.1-9
    • /
    • 2005
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the healthy effectsrelated to IAQ, specially in schools in Korea. Therefore, objectives of this study in this study were to measure and compare the perception of TAQ of selected air pollutants in Seoul from April to September 2004. Measurement place measured 2 schools of Seoul and local 9 schools (by Kyonggi Province, Chungchong-bukdo Chungchong-namdo, Chollado-bukdo, Cholla-namdo, Kyongsang-bukdo, Kyongsang-namdo, Kwangju, schoolin Pusan each 1 place). Temperature, humidity, illumination, carbon monoxide, carbon dioxide, TBC (total bacteria count), noise, PM10, TVOC(total volatile organic compounds), HCHO (formaldehyde) were measured simultaneously. Also, we Performed a questionnaire survey of 250 students and 50 teachers about their awareness for the importance of IAQ in their schools. Among this article, we handled noise, carbon monoxide, carbon dioxide, TBC, TVOC, HCHO, PM 10 in our conclusion. Major results were as follows ; Carbon monoxide (CO) was lower than indoor air standard of Korea. Carbon dioxide $(CO_2)$ appeared that 4 schools among our sample target school exceeded in normal standard. 4 schools were almost similar with normal standard. TBC appeared that 7 schools among 11 schools were higher than standard. Noise measured school's mean value passed exceeded standard. And school which passed over standard appeared to 7 schools among 11 schools. HCHO was exceeded 4 schools by standard that excess and certainly interrelation between school's establishment year and facilities of construction was detected. PM10 was exposed all schools by fitness in standard. TVOC appeared that 9 schools among 11 measurement school was exceeded health effect standard of Japan.

Analysis of Heating and Cooling Load Profile According to the Window Retrofit in an Old School Building (노후 학교건물의 창호 교체에 따른 부하분석)

  • Lee, Ye Ji;Kim, Joo Wook;Song, Doo Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.455-462
    • /
    • 2017
  • The purpose of this study is to analyze heating and cooling load variation due to envelope retrofits in an old school building. In a previous study, envelope retrofit of an old school building resulted in annual energy consumption reduction. However, cooling energy consumption increased with the envelope retrofit. This is because of high internal heat generation rates in school buildings and internal heat cannot escape through windows or walls when the envelope's thermal performance improves. To clarify this assumption, thermal performance changes due to envelope retrofits were analyzed by simulation. Results revealed indoor temperature and inner window surface temperature increased with high insulation level of windows. Indoor heat loss through windows by conduction, convection and radiation decreased and resulted in an increase of cooling load in an old school building. From results of this study, energy saving impact of envelope retrofits in an old school building may not be significant because of high internal heat gain level in school buildings. In case of replacing windows in school buildings, local climate and internal heat gain level should be considered.

Effect of Carbonization Temperature on Hygric Performance of Carbonized Fiberboards

  • Lee, Min;Park, Sang-Bum;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.615-623
    • /
    • 2014
  • Increases of public attention on healthy environment lead to the regulation of indoor air quality such as Clean Healthy House Construction Standard. This standard covers emission of total volatile organic compounds (TVOCs) (e.g., formaldehyde, benzene, and toluene), ventilation, and use of environmentally-friendly products or functional products. Moisture absorption and desorption abilities are a recommended functionality for improving indoor air quality. In this study, moisture absorption and desorption capacities of carbonized board from wood-based panels and other materials were determined by using UNT-HEAT-01 according to ISO 24358:2008. Pine had higher moisture absorption and desorption capacities ($49.0g/m^2$ and $35.3g/m^2$, respectively) than hinoki cypress, cement board, gypsum board, oriented strand board, and medium density fiberboard (MDF). The moisture absorption and desorption capacities differed considerably according to the wood species. After carbonization process at $400^{\circ}C$, the absorption and desorption ability of MDF increased to 38% and 60%, respectively. However, moisture absorption and desorption capacities decreased with increasing carbonization temperature, but they were still higher than original MDF. Therefore, it is suggested that carbonization below $600^{\circ}C$ can improve moisture absorption/desorption capacities.

Theoretical Study on Heat Exchanger Performance of a Fin-tube Evaporator with Frost Growth in a $CO_2$ Refrigerator Truck (이산화탄소 냉매를 이용한 냉동탑차용 핀-관 증발기의 서리성장에 따른 열교환기 성능에 관한 해석적 연구)

  • Myung, Chi-Wook;Cho, Hong-Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.48-54
    • /
    • 2012
  • To analyze the cooling performance of fin-tube evaporator in the refrigerator truck using R744 according to frost growth, the analytical model of evaporator was developed under frost and non-frost conditions. The performance of fin-tube evaporator was investigated with frost thickness and indoor temperature. Besides, the performance of evaporator under frost condition was compared to that under non-frost condition. As a result, area of air passage and system performance were decreased as the frost thickness increased. The cooling capacity was reduced by 10%, 20%, 30% when the frost thickness was 0.7 mm, 1.1 mm, and 1.6 mm respectively. At these conditions, the block ratio was 31%, 48%, and 71%. In addition, the outlet quality of refrigerant was not over 1 when the frost thickness was 1.6 mm in spite of high indoor air temperature.

Influence Factors on Health of Dental Hygienist by Dental Office's Indoor Air Quality (치과위생사의 병원실내공기질에 의한 건강영향요인)

  • Park, Myung-Suk;Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of dental hygiene science
    • /
    • v.8 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • This survey was compared and analyzed about the primary factor that dental office's working environment effect on physical subjective symptom and based on self-filling survey, 656 dental hygienists on July through August 2006, and analyzed using descriptive statics, ANOVA and Multiple Regression Analysis. The result of satisfaction degree of hospital working environment was pretty low about office air condition. Most people have complained that office's air quality makes it difficult to their work and mentioned that they were sore and dull all over the back, shoulder, and neck. The odor is major factor to be satisfied with office environment. Proper ventilates the way open the window more often was essential to maintain fresh indoor air quality and keep the extraction materials by separator and sealing tightly for remove the odor. Other factors were temperature, lighting fixture, ventilation facilities, and freshness of air. Dental hygienist was unsatisfied with hospital air condition and this polluted air condition was the cause of physical subjective symptom in work place. Furthermore, this research would be applied for improvement of working environment by decreasing of indoor air pollution.

  • PDF