Energy Saving Effect of the Night Purge Control using ERV in a School Building (전열교환형 환기시스템을 이용한 학교건물의 나이트 퍼지 적용 효과 분석)

  • Kim, Su-Yeon;Won, Jung-kwan;Kim, Jae-Hyung;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.421-427
    • /
    • 2016
  • The indoor temperature of a building increases during the day due to solar radiation. This behavior is significant in school buildings that are finished with high thermal capacity materials. Moreover, in school buildings, windows cannot be opened until the class has finished owing to the security policy of schools. Consequently, classrooms maintain a high temperature throughout the morning. It is thus important to remove the indoor heat before the commencement of classes in order to reduce the cooling energy needed. The Energy Recovery Ventilator (ERV) system is currently being installed in school buildings for ventilating the classrooms. Night-purge control using ERV can be a good strategy to cool the classroom in advance of the operation of the cooling system. However, the optimal operation method of the ERV for night-purge control has not yet been reported. In this study, the effect of night-purge control with ERV in school buildings is analyzed by simulation method. The results of this study showed that the energy saving effect of night-purge control with ERV is most effective in the case of 2 hours operation prior to the commencement of the first lass and when enthalpy based outdoor air cooling is used.

A study of frequency control of an inverter heat pump for indoor air temperature adjustment (실내온도조절을 위한 인버터 열펌프의 주파수 제어에 관한 연구)

  • Park, Yun-Cheol;Min, Man-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1262-1272
    • /
    • 1997
  • An experimental study on the frequency control of an inverter heat pump to get the desired indoor room temperature has been conducted for the performance characteristics during the steady, 4, 8, and 16 step frequency operations. The heat pump model used in this study was operated to meet the experimental conditions of ASHRAE standard. The performance of the system was tested by measuring the temperature and pressure of the refrigerant, and cooling capacity, power consumption, etc. of the system. As the controlling frequency steps increased, the running time of the compressor increased as well as the electric consumption of the system and the cooling energy due to the wall heating load. However, the average cooling COP was improved.

Study on the Personal Air-Conditioning System Considering Human Thermal Adaptation (인간의 열적 적응성을 고려한 퍼스널 공조시스템의 개발)

  • 송두삼
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.524-532
    • /
    • 2003
  • In this paper, a personal air-conditioning system considering the human thermal adaptability is analyzed. Although the conventional personal air-conditioner was proofed to be satisfactory in providing for the thermal comfort, it is being questioned on the term of its energy efficiency. Therefore, it is important and urgent to develop new types of personal air-conditioning system with sustainable control strategy that can ensure energy saving and thermal comfort simultaneously. In this study, we first examined the problems of the conventional personal air-conditioning system with field interview and laboratory experiment in terms of usage, management and thermal comfort, and proposed the energy-saving personal air-conditioning system considering the human thermal adaptation. Then a laboratory experiment was performed to analyze the characteristics of the human thermal comfort under severe indoor thermal conditions, which were controlled using a new personal air-conditioning unit designed according to the proposal. The results help to illustrate the alleviation effect of the new personal air-conditioning system, and indicate that the thermal alleviation time is useful to maintain the thermal comfort with efficient usage of energy.

A Study on the Environmental Performance Level Measurement in the Lecture Room during Winter Time (동계 대학강의실 환경성능수준 측정에 관한 연구)

  • Ahn, Tae-Kyung
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.2
    • /
    • pp.3-9
    • /
    • 2018
  • This study is designed to measure the indoor environment and research on the environmental situation in the lecture room where the lecture is conducted during the winter time in order to understand the level of environment in the lecture room and then suggest the method of improving the environment in the lecture room in the future. The findings are as follows. First, the number of ventilation measured at Lecture Room 1 was 1.2 times/hour while that at Lecture Room 2 was 2.2 times/hour. Second, the lighting at Lecture Room 1 and 2 was 650~700 lux while the noise at Lecture Room 1 and 2 was not more than 60dB. Third, Group 1 and Group 2 felt in the same way that the air quality in the lecture room was not good when the air quality was measured in 30 minutes after the start of lecture. Fourth, both Group 1 and Group 2 showed the lowered concentration on the class in 30 minutes after the start of the class when the room was heated. But Group 1 got less drop in the concentration when they was put in the non-heated room. Fifth, As for the change in the carbon dioxide volume during lecture, the carbon dioxide volume in the room where the windows was closed rose 1,000~1,400ppm from that at the time of start, thus showing that the indoor air quality got worsened. In addition, it is hard to control the indoor temperature due to the heating and non-heating. Accordingly, it is necessary to get the heating system which can make the ventilation in order to keep the environmental level in the lecture room to a certain level and keep the proper indoor temperature.

Development of Environmental Control Systems for Windowless Pig-housing (I) - Assessment of Control Performance - (무창돈사의 환경제어 시스템 개발 (I) - 제어성능의 평가 -)

  • 장홍희;장동일;임영일
    • Journal of Biosystems Engineering
    • /
    • v.24 no.5
    • /
    • pp.415-424
    • /
    • 1999
  • This study was conducted to assess performances of the developed environmental control systems under various seasons of Korea. In all trials for the environmental control systems, the manure pit ventilation system in the windowless pig-housing with partly slatted floor was used. Consequently, under all seasons of Korea, the complex environmental control systems could comfortably maintain the indoor temperature (14.8~27.2$^{\circ}C$) , concentrations of noxious gases (CO2 gas : 631~1,874ppm, NH3 gas : 0.3~3.2ppm), air velocity (0.11~0.23m/s), air movement, and so on. Therefore, the performances of the complex environmental control systems were evaluated as proper as the intended.

  • PDF

(On designing Temperature Control System of the Air-conditioner using immune system) (면역 시스템을 이용한 에어콘의 온도 제어 시스템 설계)

  • Seo, Jae-Yong;Jo, Hyeon-Chan;Jeon, Hong-Tae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • In this paper, we propose temperature inference system for indoor and outdoor temperature of the Air-Conditioner with limited sensors. The proposed system based on the network theory of biological immune system consists of indoor and outdoor temperature inference process. It is designed that on-line temperature inference is possible. This system is admirable for unlearned data as well as given input data by making efficient use of previous information.

An Study on the Evaluation of Thermal Indoor Environment and Thermal Sensations during Winter and Summer in Elderly Welfare Facilities (老人福祉施設의 冬.夏節期 室內 溫熱環境 測定 및 溫熱感 評價)

  • Kwak, Ho;Ryoo, Woo-Dong;Hwang, Kwang-Il;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2003
  • This study aims to survey the living spaces of the welfare facilities for the aged to get the objective relationships between the physical thermal environment and the users' subjective responses. The surveys were made twice in winter and once in summer during 2001 and 2002. An ambient temperature, relative humidity, air velocity, globe temperature were measured as physical elements of thermal environment and the ASHRAE Psychophysical Voting Scale were used as an evaluation index for subjective responses. As the results, the aged respond thermally comfortable, in spite of the differences among important factors such as thermal sensations, humidity sensations and air velocity sensations. Also the physical thermal environmental elements and the subjective responses indices exceed thermal comfort range calculated by PMV(Predicted Mean Vote) and PPD(Predicted Percentage Dissatisfied). It shows that the insulation of walls of the facilities is not enough for heating and cooling seasons, and the indoor environmental control is necessary.

An Experimental Study for Evaluating Performance of Radiant Floor Cooling System Integrated with Dehumidification (제습기능이 통합된 바닥복사 냉방시스템의 용 가능성에 관한 실험적 연구)

  • 이상엽;황석호;김가현;이승복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.143-152
    • /
    • 2002
  • It is critical for radiant floor cooling system using Ondol to cause condensation on a floor surface. To solve this problem, a radiant floor cooling system integrated with dehumidification was proposed and evaluated in terms of its applicability and prevention of condensation. Therresults show that the proposed system of radiant floor cooling integrated with dehumidification properly maintained the indoor setpoint temperatures and prevented the condensation on a floor surface. To achieve more stable indoor temperatures and humidity control, a further study for the operation of dehumidification panel will be needed.

A Practical Approach to the Real Time Prediction of PM10 for the Management of Indoor Air Quality in Subway Stations (지하철 역사 실내 공기질 관리를 위한 실용적 PM10 실시간 예측)

  • Jeong, Karpjoo;Lee, Keun-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2075-2083
    • /
    • 2016
  • The real time IAQ (Indoor Air Quality) management is very important for large buildings and underground facilities such as subways because poor IAQ is immediately harmful to human health. Such IAQ management requires monitoring, prediction and control in an integrated and real time manner. In this paper, we present three PM10 hourly prediction models for such realtime IAQ management as both Multiple Linear Regression (MLR) and Artificial Neural Network (ANN) models. Both MLR and ANN models show good performances between 0.76 and 0.88 with respect to R (correlation coefficient) between the measured and predicted values, but the MLR models outperform the corresponding ANN models with respect to RMSE (root mean square error).

A Study on Building Energy Saving using Outdoor Air Cooling by Load Prediction (부하예측 외기냉방에 의한 건물에너지 절약에 관한 연구)

  • Kim, Tae-Ho;Yoo, Seong-Yeon;Kim, Myung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.43-50
    • /
    • 2017
  • The purpose of this study is to develop a control algorithm for outdoor air cooling based on the prediction of cooling load, and to evaluate the building energy saving using outdoor air cooling. Outdoor air conditions such as temperature, humidity, and solar insolation are predicted using forecasted information provided by the meteorological agency, and the building cooling load is predicted from the obtained outdoor air conditions and building characteristics. The air flow rate induced by outdoor air is determined by considering the predicted cooling loads. To evaluate the energy saving, the benchmark building is modeled and simulated using the TRNSYS program. Energy saving by outdoor air cooling using load prediction is found to be around 10% of the total cooling coil load in all locations of Korea. As the allowable minimum indoor temperature is decreased, the total energy saving is increased and approaches close to that of the conventional enthalpy control.