Estimation of NO$_2$ Source Generation and Ventilation rate in Residence by Multiple Measurements

  • Won Ho, Yang;Gi Yeong, Lee
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.05a
    • /
    • pp.155-160
    • /
    • 2003
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor $NO_2$ concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential $NO_2$ deposition constant of 1.05 $hr^{-1}$, and 1.36 ACH in Seoul, with the measured residential $NO_2$ deposition constant of 0.94 $hr^{-1}$. Source strengths of $NO_2$ were 15.8 $\pm$ 18.2 ${\mu}g$/$m^3$.hr and 44.7 $\pm$ 38.1${\mu}g$/$m^3$.hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

Evaluation of Pollutants Emissions according to the Selling Store in Department Store (백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가)

  • Wang, HyeongSeok;Hwang, JunSeok;Chang, SeongJin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.1
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).

The Indoor Propagation Modeling for Indoor Wireless LAN Service (실내 무선 랜 서비스를 위한 실내 전파 모델링)

  • 김진웅;김기홍;윤영중;석재호;임재우;신용섭
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.5
    • /
    • pp.426-435
    • /
    • 2002
  • In this paper we present an indoor propagation model for indoor wireless LAN service in the ISM band. We primarily use a 3D ray tracing as well as a patch scattering model in order to take into account the indoor fixtures. Therefore input parameters such as indoor environment parameters and antenna's types, polarizations are considered. As the results, we present fading characteristics and rms delay spread from time delay spread. In order to investigate the accuracy of the presented model, comparisons of predictions with measurement and simulations are performed in indoor wireless LAN service environments. The results show that measurements and simulations are very similar. Therefore in this paper, the effect of presented indoor propagation model is confirmed.

A Study on Indoor Thermal Environment in an Tower Type Apartment House at Tropical Nights (여름철 열대야 발생시 탑상형 아파트의 실내온열환경에 대한 연구)

  • Chang, Hyun-Jae;Kim, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.

Recent Advances in Titania-based Composites for Photocatalytic Degradation of Indoor Volatile Organic Compounds

  • Raza, Nadeem;Kim, Ki-Hyun;Agbe, Henry;Kailasa, Suresh Kumar;Szulejko, Jan E.;Brown, Richard J.C.
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.217-234
    • /
    • 2017
  • Indoor air pollutants can cause severe health problems, specifically in terms of toxicological impacts on human. Every day, a complex mixture of many air pollutants is emitted from various sources and subject to atmospheric processes that can create varied classes of pollutants such as carboxylic acids, aldehydes, ketones, peroxyacetyl nitrate, and hydrocarbons. To adhere to indoor air quality standards, a number of techniques such as photocatalytic oxidation of various volatile organic compounds (VOCs) have been employed. Among these techniques, titania ($TiO_2$) based photocatalytic reactions have proven to be the best benchmark standard approach in the field of environmental applications. Over the last 45 years, $TiO_2$-based photocatalytic reactions have been explored for the degradation of various pollutants. This review discusses the indoor air quality profile, types of indoor pollutants, available indoor air cleaning approaches, and performance of $TiO_2$-based catalysts. Finally, we have presented the perspectives on the progress of $TiO_2$ induced photocatalysis for the purification of indoor air.

Evaluation of the Indoor Thermal Comfort in Naturally Ventilated Apartment During Summer (자연환기가 가능한 서울시 공동주택의 하절기 실내 온열 쾌적성 평가)

  • Lee, Seung-Jae;Cheong, Chang Heon;Hwang, Suckho;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.59-66
    • /
    • 2010
  • Natural ventilation is major strategy of 'sustainable building'. It aims to supply fresh air to the indoor, and to remove heat from the indoor during summer. In the latter point of view, natural ventilation can be grouped into two main strategies, daytime ventilation and night cooing. If we take advantage of these two natural ventilation strategies, indoor thermal comfort can be significantly improved. This study focused on grasping the current situation and problem of indoor thermal comfort of the naturally ventilated residential buildings to seek for direction of later studies. Additionally, thermal comfort of residence where the interior blind and exterior insulation were applied was analyzed. It was analyzed that the percentage of the time which satisfy the indoor acceptable operative temperature during summer was 90 ~ 95% and the heat control performance of natural ventilation has a limitation. When the interior blind and exterior insulation were applied, indoor thermal comfort was significantly improved. However, it still need more improvement.

The Characteristic of Volatile Organic Compounds(VOCs) Emission from the Type of Indoor Building Materials as the Temperature and Humidity (온.습도에 따른 건축 내장재별 휘발성유기화합물의 방출특성)

  • Seo, Byeong-Ryang;Kim, Shin-Do;Park, Seong-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.292-303
    • /
    • 2006
  • The Volatile Organic Compounds(VOCs) are emitted from various sources and have lots of different form. Recently human are spending the many times at indoor area and indoor air pollution is issued the important social problem. The emission sources of indoor air pollutants are very various, also indoor building materials are composed of very complex chemical compounds, these indoor building materials discharge very much VOCs and other hazardous compounds. In this study, we performed the small chamber test to investigate the VOCs emission concentration and characteristics involving five kinds of the indoor building materials(furniture material, wooden floor, wall paper, paint and tile) under different conditions of four temperature and relative humidity as account of the air flow rate(AFR), air exchange rate(AER), loading factor and air velocity respectively. As the result, It was showed that building materials are emitted the highest VOCs concentration at the beginning of experiment and furniture material is emitted the highest VOCs concentration. Most of the materials were affected by temperature, but paint and tile material were affected by humidity.

An Investigation and Analysis into the Architectural Conditions and Indoor Air Quality of Senior Citizens Public Welfare Institution in Incheon (인천지역 공공 노인복지시설의 건축조건과 실내공기질에 대한 실태조사 및 분석)

  • Kang, Seung A;Shin, Sung Shik;Kim, Yong Shik
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.59-64
    • /
    • 2009
  • The senior citizens population and welfare institution for them is increased. The senior citizens in welfare institution spend a long time in indoor and their health is greatly affected by the indoor environment. Therefore, the indoor environment of senior citizens welfare institution is very important. This study presents some primary data based on the survey of architectural conditions and the measurements of indoor air quality for senior citizens welfare institution. According to characteristic of region, six of Incheon Area's senior citizens public welfare institution are selected. An investigation and analysis into architectural conditions and indoor air quality including temperature, humidity, CO, $CO_2$, PM10, HCHO, TVOC are conducted. The temperature, humidity and $CO_2$ concentration is some high. The HCHO concentration is very high. The indoor flooring and furniture materials highly impacts on the concentration of HCHO and TVOC.

Indoor Network Map Matching by Hidden Markov Model (은닉 마르코프 모델을 이용한 실내 네트워크 맵 매칭)

  • Kim, Tae Hoon;Li, Ki-Joune
    • Spatial Information Research
    • /
    • v.23 no.3
    • /
    • pp.1-10
    • /
    • 2015
  • Due to recent improvement of various sensor technologies, indoor positioning becomes available. However, Indoor positioning technologies by Wi-Fi radio map and acceleration sensor and digital campus still have a certain level of errors and a number of researches have been done to increase the positioning accuracy of the indoor positioning. If we could provide a room level accuracy, indoor location based services with current indoor positioning methods such as Wi-Fi radio map and acceleration sensors would be possible. In this paper, we propose an indoor map matching method to provide a room level accuracy based on hidden markov model.

Estimation of Nitrogen Dioxide Source Generation and Ventilation Rate in Residence Using Multiple Measurements in Korea

  • Chung, Moon-Ho;Yang, Won-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.12a
    • /
    • pp.45-50
    • /
    • 2004
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Alt hough technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor NO2 concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and NO2 source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential NO2 deposition constant of 1.05 hr-1, and 1.36 ACH in Seoul, with the measured residential NO2 deposition constant of 0.94 hr-1. Source strengths of N02 were 15.8 ${\pm}$ 18.2 ${\mu}$g/m3${\cdot}$hr and 44.7 ${\pm}$ 38.1 ${\mu}$g/m3${\cdot}$hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF