• 제목/요약/키워드: Indirect evaluation method

검색결과 183건 처리시간 0.025초

Temperature change around a LNG storage predicted by a three-dimensional indirect BEM with a hybrid integration scheme

  • Shi, Jingyu;Shen, Baotang
    • Geosystem Engineering
    • /
    • 제21권6호
    • /
    • pp.309-317
    • /
    • 2018
  • We employ a three-dimensional indirect boundary element method (BEM) to simulate temperature change around an underground liquefied natural gas storage cavern. The indirect BEM (IBEM) uses fictitious heat source strength on boundary elements as basic variables which are solved from equations of boundary conditions and then used to compute the temperature change at other points in the considered problem domain. The IBEM requires evaluation of singular integration for temperature change due to heat conduction from a constant heat source on a planar (triangular) region. The singularity can be eliminated by a semi-analytical integration scheme. However, it is found that the semi-analytical integration scheme yields sharp temperature gradient for points close to vertices of triangle. This affects the accuracy of heat flux, if they are evaluated by finite difference method at these points. This difficulty can be overcome by a combination of using a direct numerical integration for these points and the semi-analytical scheme for other points distance away from the vertices. The IBEM and the hybrid integration scheme have been verified with an analytic solution and then used to the application of the underground storage.

Proposing a Method for Robustness Index Evaluation of the Structures Based on the Risk Analysis of Main Shock and Aftershock

  • Abdollahzadeh, Gholamreza;Faghihmaleki, Hadi
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1710-1722
    • /
    • 2018
  • Investigating remained damages from terrible earthquakes, it could be concluded that some events including explosion because of defect and failure in the building mechanical facilities or caused by gas leak, firing, aftershocks, etc., which are occurred during or a few time after the earthquake, will increase the effects of damages. In this paper, by introducing a complete risk analysis which included direct and indirect risks for earthquake (the main shock) and aftershock, the corresponding robustness index was created that called as "robustness index sequential critical events risk-based". One of the main properties of the intended robustness index is using progressive collapse percentage in its evaluation. Then, in a numerical example for a 4-storey moment resisting steel frame structure, a method is presented for obtaining all effective parameters in robustness index evaluation based on the intended risk and at last its results were reported.

국내 공공 공사 하도급계약 공기연장 추가간접비 산정방안 (The Calculation Method for Prolongation cost of Sub-Constract in Domestic Public Construction Project)

  • 정기창;이재섭
    • 한국건설관리학회논문집
    • /
    • 제19권4호
    • /
    • pp.61-69
    • /
    • 2018
  • 원도급계약에서의 공기연장 추가간접비에 대한 연구는 지속되어왔다. 그러나 하도급계약에서의 공기연장 추가간접비 산정방식에 대한 연구는 거의 없는 실정이다. 본 연구는 기존 현장에서 사용되고 있는 공기연장 추가간접비 산정방식과 선행연구에서 제안된 공기연장 추가간접비 산정방식에 대해 고찰하고 모형사례를 분석하여 산정방식을 비교하였다. S-curves형태의 간접비 발생을 반영한 모형사례의 발생상황을 사례별로 제시하여 선행연구에서 제시된 공기연장 추가간접비 산정방식별 산출결과를 비교하였다. 산정방식의 문제점을 고찰하는 과정에서 원사업자의 공기연장 추가간접비 산정방식으로 타당한 것으로 연구된 바 있는, 지연기간 평균실비산정방법이 수급사업자의 공기연장 추가간접비 산정에도 타당하다는 결론을 도출하여 보편적으로 적용될 수 있음을 입증하였다.

간접 힘 측정 방법과 가상 역행렬을 이용한 힘 예측 (Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique)

  • 안병하;심재술
    • 한국정밀공학회지
    • /
    • 제19권6호
    • /
    • pp.43-50
    • /
    • 2002
  • In the design of structure, the forces acting on tai structure are key parameter fur noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. So, it is necessary to find out Indirect force evaluation method. In this paper, forces have been measured with In-situ vibration responses and system information. And, three existing techniques of indirect force measurement, vita. direct inverse. principal component analysis and regularization have been compared. This paper shows that multi-vibration responses are essential for talc precise estimation of the forces. To check these conditions, rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It alas also been obtained that relatively higher force is transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate.

석조문화재 풍화도 평가를 위한 초음파 측정의 설정과 직접-간접전달방법의 상관관계 (Establishment of Ultrasonic Measurement and Correlations of Direct-Indirect Method for Weathering Evaluation of Stone Cultural Heritage)

  • 이찬희;조영훈;전유근
    • 보존과학회지
    • /
    • 제25권3호
    • /
    • pp.233-244
    • /
    • 2009
  • 이 연구에서는 석조문화재의 초음파 측정에 적합한 탐촉자 및 접촉매질을 선정하였으며, 과학적이며 정량적인 평가기술을 개발하기 위해 암종별 직접 및 간접전달방법의 상관관계를 분석하였다. 이 결과, 석조문화재에서 초음파 측정은 유형 3의 탐촉자(UTREXTX(RX)54kHz)와 접촉매질(고무찰흙)을 사용하는 것이 가장 적합한 것으로 나타났다. 또한 이 유형 3의 직접 및 간접전달방법의 보정계수는 화강암 1.50, 반려암 1.38, 석영섬록암 1.58로 산출되었다. 이 결과는 초음파탐사의 신뢰도를 높이기 위한 최초의 연구로서 석조문화재의 초음파탐사 방법을 확립하는데 크게 기여할 것으로 판단된다. 또한 암석의 표면요철도와 다양한 접촉매질을 고려한 보완연구가 수행되어야 할 것이며, 암종별 직접-간접전달방법의 상관관계에 대한 데이터베이스도 구축되어야 할 것이다.

  • PDF

ISO 10767-1에 기초한 유압 펌프의 유량 맥동 측정 및 정밀도 평가 (Measurement of Hydraulic Pump Flow Ripple Characteristics Based on the ISO 10767-1 and the Evaluation of the Measuring Accuracy)

  • 김지웅;강만곤;이일영
    • 유공압시스템학회논문집
    • /
    • 제4권3호
    • /
    • pp.22-27
    • /
    • 2007
  • The source flow ripple and the source impedance in hydraulic pump are characteristic values showing fluid-borne vibration characteristics decisively. We cannot measure these two characteristic values directly, but can measure them by some indirect methods. One representative indirect measuring method is ISO 10767-1. The authors constructed a hardware and a software for the measuring method based on ISO 10767-1. Through the error evaluation of the measured results, accuracy of the measuring method using ISO 10767-1 was examined in detail.

  • PDF

연속 다짐 평가에 관한 연구 (Study of the Intelligent Compaction Evaluation)

  • 박근보;김주형;조삼덕
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.722-729
    • /
    • 2010
  • In this study, we considered the development for degree of compaction for intelligent compaction. In practice, any direct or indirect method can be used as a intelligent compaction method. A series of field tests was conducted using an accelerometer. This is quick and simple indirect methods of measuring soil stiffness. Each result was compared with the results from a plate load test. A prototype device for intelligent compaction was developed, and we evaluated its performance.

  • PDF

국내 산업들의 물 발자국 산정에 관한 연구 (A Study about Water Footprint Evaluation of Industrial Sectors)

  • 김준범;강헌;박기학
    • 대한환경공학회지
    • /
    • 제35권6호
    • /
    • pp.400-406
    • /
    • 2013
  • 물 발자국(Water footprint)은 단위 제품 및 단위 서비스 생산 전과정(life cycle) 동안 직접 및 간접적으로 이용되는 물의 총량지표를 나타내는 것을 의미한다. 본 연구에서는 물 발자국 산정 방법을 이용하여 국내 산업에서의 직접 및 간접적인 용수량을 산정하여 효과적인 수자원 관리를 위한 하나의 방법을 제시하고자 하였다. 연구 결과로는 원단위 용수계수가 가장 큰 산업은 농림수산품으로 약 637 $m^3/won$으로 전체 산업의 93%를 차지했다. 농림수산품 다음으로 간접적인 원단위 용수계수가 큰 산업은 석유 및 석탄 제품으로 약 13 $m^3/won$을 나타냈다. 산업연관용수량의 경우 간접적인 용수량이 가장 많은 산업 역시 농림수산품으로 직접적인 용수량이 약 25억 $m^3$인데 비해 간접적인 용수량은 약 130억 $m^3$ 정도로 나타났으며, 조사한 전체 16개 산업 중 91%를 차지했다. 화학제품의 경우 직접적인 용수량이 약 2억 $m^3$, 간접적인 용수량은 약 4억5천만 $m^3$으로 나타났다. 연구결과 직접적인 용수량보다 간접적인 용수량이 전체적으로 큰 것으로 나타났으며, 이와 같이 국가적으로 전체 산업별 물 발자국 및 용수량의 흐름을 파악함으로써, 국가의 수자원 관리 정책 수립 시 기초자료로 활용 되어질 수 있을 것으로 사료된다.

Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구 (A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System)

  • 홍선숙;김호철
    • 전자공학회논문지
    • /
    • 제50권12호
    • /
    • pp.247-253
    • /
    • 2013
  • 본 연구의 목적은 Direct DR(Digital Radiography), Indirect DR, I.I(Image Intensifier) DR에서 X선 광자 검출 방식에 따른 선량측정 및 획득된 영상을 정량적이고 객관적인 측정을 통해 DR System을 비교 평가 하는 것이다. Rando phantom을 사용하여 입사표면선량을 측정하였으며, 측정된 입사표면선량 값을 통해 PCXMC 프로그램을 사용하여 유효선량과 방사선 조사로 인한 위험을 평가하였다. 21cm 아크릴 phantom을 사용하여 SNR(Signal to Noise Ratio), NPS(Noise Power Spectrum), CNR(Contrast to Noise Ratio)을 측정하였으며, 측정값은 통계학적 분석기법을 사용하여 유의성을 평가하였다. 입사표면선량, 주요장기선량, 유효선량 모두 direct DR이 가장 낮게 측정되었으며, direct DR 선량을 기준으로 I.I type DR은 약 1.3배, indirect DR은 약 2.4배 높은 선량 비율로 측정되었다. 방사선량에 따른 위험도 역시 동일한 비율로 측정되었다. SNR 측정 결과 direct DR측정값을 기준으로 I.I DR은 약 7.25배, indirect DR이 약 1.48배 낮은 비율로 측정되었다. CNR 측정 결과 direct DR 측정값을 기준으로 I.I DR은 약 1.16배 높고, indirect DR이 약 0.87배 낮은 비율로 측정되었다. 따라서 a-selenium 검출소자를 사용하여 X선 광자를 검출하는 방식인 direct DR은 적은 선량으로 우수한 화질의 영상을 구현함으로써 선량에 민감한 소아나 생식선이 포함된 검사 등에 유용할 것으로 사료된다. 또한 많은 진단 정보를 위한 영상 평가가 요구되는 경우에는 indirect DR이 유용할 것으로 판단된다.

간접방류사업장 관련 폐수의 생태독성수준 및 특성 평가 (Evaluation of Ecotoxicity and Characteristics on Indirect Effluents and Related Wastewater)

  • 김종민;신기식;이수형;이정서;이택준
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.481-486
    • /
    • 2017
  • This paper aims to evaluate the characteristics of direct and indirect effluents'toxicity level and difference between two test durations (24 h and 48 h) of test method. The proportion of the indirect effluent samples which exceeded the ecotoxicity permit limitations (TU 1 or TU 2) showed more than 2 times higher than that of direct effluent samples. However, effluent toxicity of Wastewater Treatment Plants (WTPs) indicated less than TU 1 regardless of influent toxicity. From this results, treatment process was thought to have a good efficiency. WTP Salinity was very similar between influent and effluent. This trend could be reconfirmed by the component ratio of ion concentration between them and $Na^+$, $SO_4^{2-}$, $C^-$ lions which have a greater percentage than other ions. In addition, in case of high salinity, toxicity value also showed high level. To judge from above results, indirect effluents which were exempted from application of ecotoxicity standards, may need a new effluent limitations regardless of the treatment efficiency of WTP. According to circumstances, effective countermeasure may need to restrain the discharge of salinity-contained effluents which came from indirect-effluent factories. Test duration comparative study indicated that 48 h results were higher toxicity (exceeding rate of ecotoxicity criteria) than 24 h by the 5 to 5.4 percentage. 24 h test duration seemed to be useful in case of rapid detection, whereas 48 h test method could be applied for reinforcement of ecotoxicity regulatory system.