• Title/Summary/Keyword: Indirect Evaluation

Search Result 503, Processing Time 0.021 seconds

A Study on Major Factors on Patient Satisfaction of General Hospitals in Korea - Analysis of factors associated with in Health Service Evaluation Program by the Korean Government - (종합병원 입원환자와 외래환자의 만족도 요인 분석 - 의료기관 서비스평가 자료를 활용한 실증 분석 -)

  • Bae, Sung-Kwon;Nam, Eun-Woo;Park, Jae-Young
    • Korea Journal of Hospital Management
    • /
    • v.10 no.2
    • /
    • pp.26-44
    • /
    • 2005
  • The purpose of this study was to investigate these major factors on patient satisfaction, and to examine the affecting level of major factors in. The subjects in this study was 70 hospitals that were surveyed the hospital evaluation program containing the survey of patient satisfaction by KHIDI(Korea Health Industry Development Institute) from 1997 to 1999. The collected data was analysed SPSS for Windows(Ver 10.0). On basically, frequency analysis, t-test, and ANOVA was performed and, for more analysis, correlation analysis, factor analysis, multiple regression analysis, logistic regression analysis was utilized. According to this study, the major factors of inpatient satisfaction are divided 3 types facility factor, manpower factor, and service factor. And the major factors of outpatient satisfaction are analyzed 5 types; facility factor related direct medical service, facility factor related indirect medical services, manpower factor, pharmacy factor, and facility factor related utilization convenience. The importance of this study lies in the identification of major factors on hospital patient satisfaction.

  • PDF

A Study on Field Applicability Evaluation of the Hydrophobic - Low Viscosity Surface Treatment Material for Pavement Preventive Maintenance (소수성 특성을 이용한 저점도 AP 표면처리재의 현장 적용성 연구)

  • Choi, Jun Seong
    • International Journal of Highway Engineering
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 2014
  • PURPOSES : Surface treatment material for pavement preventive maintenance should be inspected field applicability. This study(Part II) aimed to checkup coating characteristics and performance analysis using lab and field tests. The hydrophobic - low viscosity filling material for pavement preventive maintenance is presented in Part I, which is a series of companion study. METHODS : Relative comparison between general asphalt mixtures and surface treatment asphalt mixtures are analyzed and measured for the field application such as indirect tensile strength ratio(TSR), abrasion resistance, crack propagation resistance, temperature resistance, coating thickness, permeability resistance and skid resistance in terms of british pendulum number(BPN). RESULTS : It is found that TSR, crack propagation resistance and permeability resistance is increased as against uncoated asphalt specimen. Abrasion resistance and temperature resistance is secured from the initial coating thickness point of view, which is about 0.2~0.3mm. Skid resistance on the surface treatment pavement is satisfied with the BPN criteria of national highway because of exposed aggregate and crack sill induced pavement deterioration and damage cracks. CONCLUSIONS : The hydrophobic - low viscosity surface treatment material for pavement preventive maintenance is validated on field applicability evaluation based on quantitative analysis of coating thickness and performance analysis using lab and field tests.

National genomic evaluation of Korean thoroughbreds through indirect racing phenotype

  • Lee, Jinwoo;Shin, Donghyun;Kim, Heebal
    • Animal Bioscience
    • /
    • v.35 no.5
    • /
    • pp.659-669
    • /
    • 2022
  • Objective: Thoroughbred horses have been bred exclusively for racing in England for a long time. Additionally, because horse racing is a global sport, a healthy leisure activity for ordinary citizens, and a high-value business, systematic racehorse breeding at the population level is a requirement for continuous industrial development. Therefore, we established genomic evaluation system (using prize money as horse racing traits) to produce spirited, agile, and strong racing horse population Methods: We used phenotypic data from 25,061 Thoroughbred horses (all registered individuals in Korea) that competed in races between 1994 and 2019 at the Korea Racing Authority and constructed pedigree structures. We quantified the improvement in racehorse breeding output by year in Korea, and this aided in the establishment of a high-level horse-fill industry. Results: We found that pedigree-based best linear unbiased prediction method improved the racing performance of the Thoroughbred population with high accuracy, making it possible to construct an excellent Thoroughbred racehorse population in Korea. Conclusion: This study could be used to develop an efficient breeding program at the population level for Korean Thoroughbred racehorse populations as well as others.

Indirect evaluation of the shear wave velocity of clays via piezocone penetration tests

  • Vinod K., Singh;Sung-Gyo, Chung;Hyeog-Jun, Kweon
    • Geomechanics and Engineering
    • /
    • v.31 no.6
    • /
    • pp.623-635
    • /
    • 2022
  • This paper presents the re-evaluation of existing piezocone penetration test (CPTu)-based shear wave velocity (Vs) equations through their application into well-documented data obtained at nine sites in six countries. The re-evaluation indicates that the existing equations are appropriate to use for any specific soil, but not for various types of clays. Existing equations were adjusted to suit all nine clays and show that the correlations between the measured and predicted Vs values tend to improve with an increasing number of parameters in the equations. An adjusted equation, which comprises a CPTu parameter and two soil properties (i.e., effective overburden stress and void ratio) with the best correlation, can be converted into a CPTu-based equation that has two CPTu parameters and depth by considering the effect of soil cementation. Then, the developed equation was verified by application to each of the nine soils and nine other worldwide clays, in which the predicted Vs values are comparable with the measured and the stochastically simulated values. Accordingly, the newly developed CPTu-based equation, which is a time-saving and economical method and can estimate Vs indirectly for any type of naturally deposited clay, is recommended for practical applications.

Environmental impact evaluation and improvement measure of incineration plant by life cycle assessment (전과정평가를 이용한 소각시설의 환경영향평가 및 개선방안)

  • Kim, Hyeong-Woo;Kim, Kyeong-Ho;Park, Hung-Suck
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.4
    • /
    • pp.88-100
    • /
    • 2013
  • This study evaluated the direct and indirect environmental impacts of various unit operations of a industrial waste incineration plant by using the life cycle assessment tool and reviewed the improvement plan. During the incineration process, the direct environmental impact was decreased with decrease in emission of various air pollutants by incorporating an air pollution prevention facilities. However, an increase in indirect environmental impacts was observed as a consequence of resources and energy of consumption at the various operational facilities. Consequently, quantitative direct and indirect impact were 89.1%, 10.9%, respectively. The environmental impact analysis of system revealed the highest impact of incineration followed by the impacts of other unit processes such as semidry reactor, and bag-filter. The various air pollutants and ashes generated during the incineration process caused the most significant environmental impact. Among the various categories of environmental impact, global warming accounted the highest impact(more than 85%) followed by eutrophication, and abiotic depletion. As a result of the avoided impact by the utilization of heat generated during the waste incineration process, using an incineration heat for steam and electricity obtained the impact reduction of 45.5%, 19.8%. So, during siting of new incineration plant, the utilization of steam generated from the waste combustion is highly considered to reduce the environmental impact.

COMPARATIVE STUDY OF DIGITAL AND CONVENTIONAL RADIOGRAPHY FOR THE DIAGNOSTIC ABILITY OF ARTIFICIAL PROXIMAL SURFACE CARIES (디지털방사선사진과 구내방사선사진의 인접면 인공우식진단능에 관한 비교연구)

  • Cho, Young-Gon;Park, Si-Seung
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.113-121
    • /
    • 2002
  • Conventional intraoral radiography continues to be the most widely used image modality for the diagnosis of dental caries. But, conventional intraoral radiography has several shortcomings, including the difficulty of exposing and processing intraoral film of consistently acceptable quality. In addition, radiographic retaking that was the result of processing errors, may result in increased discomfort and radiation dose to the patient. Recently, various digital radiographies substitute for conventional intraoral radiography to overcome these disadvantages. The advantages of digital radiography are numerous. One of advantages Is the elimination of processing errors. In addition, the radiation dose for digital system is approximately 20% to 25% of that required for conventional intraoral radiography Another potential advantage of digital imaging is the ability to perform image quality enhancements such as contrast and density modulation, which may increase diagnostic accuracy. The purpose of this study was to compare the diagnostic ability of artificial proximal defects to conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). Artificial defects were made in proximal surfaces of 60 extracted human molars using #1/2, #1, #2 round bur. Five dentists assessed proximal defects on conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). ROC(Receiver Operating Characteristic) analysis and Two-way ANOVA test were used for the evaluation of detectability, and following results were acquired. 1. The mean ROC area of conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital Image(Digora$^{\circledR}$) were 0.6766, 0.7538, 0.6791(Grade I), 0.7176, 0.7594, 0.7361(Grade II), and 0.7449, 0.7608, 0.7414(Grade III), respectively. 2. Diagnostic ability of direct digital image was higher than other image modalities. But, there was no statistically significant difference among other imaging modalities for Grade I, II, III lesion(p>0.05). In conclusion, when direct and indirect digital system are comparable with conventional intraoral radiography. these systems may be considered an alternative of conventional intraoral radiography for the diagnosis of proximal surface caries.

An Exploratory Study on the Relationship with Previous Project Risk Evaluation and Project Performance (사전 프로젝트 리스크 평가와 프로젝트 성과와의 관계에 관한 탐색적 연구)

  • Hosnag, Kim;Kyungsik Yang
    • Journal of Service Research and Studies
    • /
    • v.12 no.3
    • /
    • pp.70-92
    • /
    • 2022
  • Project risk assessment is the most important activity performed at the beginning of a project because it can judge the performance of the project in advance. In this study, We were evaluated risk with traditional risk factors such as technology and schedule, etc, and Indirect risks factors such as financial, strategic, and special risks. and then, we analyzed what kind of relationship these risk evaluation factors have on business performance and customer satisfaction. As a result of the research, it was found that the risk evaluation items had a relationship with performance and customer satisfaction. However, It is possible that the performance may differ depending on how risks are managed after risk assessment. Therefore, follow-up studies should be conducted, including information on risk management practices. This study is meaningful that presenting practical risk evaluation items and at the same time identifying the relationship with performance. We plan to further the study in future studies including the evaluation of risk management process.

Clinical Evaluation of Mycoplasma pneumoniae Antibody Titer and Laboratory Tests in Acute Mycoplasma pneumoniae Pneumonia (급성기 Mycoplasma 폐렴의 항체가와 검사소견에 관한 고찰)

  • Lee, Eun Hee;Lee, So Ra;Kim, Hwa In;Kim, Jong Duck
    • Pediatric Infection and Vaccine
    • /
    • v.6 no.1
    • /
    • pp.93-100
    • /
    • 1999
  • Purpose : For evaluation of acute Mycoplasma pneumoniae(M. pneumoniae) pneumonia in children, we have studied the Mycoplasma indirect particle agglutination test, cold hemagglutinin test, ESR, CRP, and total white blood cell counts and it's differential count retrospectively. Methods : The total numbers of patients whom compatible with diagnostic criteria of acute M. pneumoniae peumonia were 56 cases from Jan. to Dec. 1997. The diagnostic criteria were 1) onset of fever(${\geq}38.0^{\circ}C$) and coughing were within 7 days, 2) rhonchi and/or role was audible on chest, 3) pneumonic infiltration on chest X-ray, and 4) M. pneumoniae indirect particle agglutination test titer was higher than 1:640, or initial titer was less than 1:640 but increased more than 4 folds after week. We classified the enrolled patients according to initial antibody titer, such as soup A(${\leq}1:640$) and group B(${\geq}1:320$). We compared group A and B by demographic findings, clinical symptoms and signs, and laboratory findings. Results : 1) The male and female sex ratio was 1:1.4, and average onset age was $5.8{\pm}2.96$ years. 2) The average body temperature on admission was $38.5{\pm}0.1^{\circ}C$ and productive coughing was noticed in 52 cases(93%). 3) The average total white cell counts were $10,470{\pm}877.0/mm^3$ in group B patients, which was significantly higher compared to $7,761{\pm}508.5/mm^3$ in group A(p<0.014). 4) The average value of ESR and CRP were within normal range in both group. 5) The most common site of pneumonic infiltration was right lower lobe of lung in both groups. 6) There were no correlation between antibody titer and cold hemagglutinine titer in patients and cold hemagglutination titer were less than 1:64 in 25 cases(45%). Conclusion : The clinical manifestations of pneumonia, findings of chest x-ray, and indirect particle agglutination test were useful on diagnosis of M. pneumoniae pnumonia onset within 7 days, but cold hemagglutinin test was a little diagnostic meaning.

  • PDF

Development of Importance Evaluation System for National Major Infrastructures using AHP Method (AHP기법을 이용한 국가 주요시설물 중요도 평가 시스템 개발)

  • Park, Jae-Woo;Kim, Seok
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.532-543
    • /
    • 2015
  • Damage of national infrastructures not only endangers the structural safety, but also has a direct and indirect influence on national economy and society. Since the influence of damage has been enhanced in the metropolitan areas, the infrastructures in danger should be identified and managed under disaster situations. This study suggests the importance factors for national infrastructures, calculates weights for the factors through AHP analysis, and develops the importance evaluation system for national infrastructures. The evaluation system provides the priority of infrastructures for local governments and facility managers and enables management based on the degree of importance in emergency situations. After disasters, the evaluation system will support a systematic decision-making for recovery priorities with a limited budget.

A study on possibility of using CST as a fouling evaluation index at MBR (MBR에서 fouling 평가지표로서 CST의 활용 가능성에 대한 연구)

  • Kim, Yun-Ji;Choi, Yun-Jeong;Sim, Tae-Suk;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.379-387
    • /
    • 2021
  • In general, trans-membrane pressure (TMP), flux, filtration resistance are used as indicators to evaluate the degree of fouling in MBR. However, they have limitations in determining the level of EPS generation, which is known as an important factor of fouling. Therefore, a new evaluation method is required to monitor the amount of EPS generation. In this study, the applicability of capillary suction time (CST), which is used to measure the dewaterability of sludge, was evaluated as an indirect fouling evaluation index. Statistical analysis was performed to evaluate the effect of EPS on CST, and to determine whether EPS has high similarity with representative fouling evaluation indicators and CST, and quantitatively compared them. As a result, the correlation coefficient between CST and bEPS was 0.7988, which was higher than the correlation coefficient between filtration resistance and bEPS. Since bEPS is a major factor inducing fouling by affecting the formation of the cake layer, it was evaluated that CST, which has a high correlation with bEPS, is suitable to represent EPS. In addition, it was evaluated that the correlation coefficient between filtration resistance and CST was high as 0.7187, which could be used as a fouling evaluation index.