• 제목/요약/키워드: Indirect Bonding

검색결과 87건 처리시간 0.024초

복합재 주익 무인항공기의 낙뢰보호 설계와 피격영역 해석 (Protection Design and Lightning Zone Analysis for Unmanned Aerial Vehicle with Composite Wings)

  • 우희채;김용태
    • 한국군사과학기술학회지
    • /
    • 제26권3호
    • /
    • pp.302-312
    • /
    • 2023
  • This paper describes the analysis of lightning strike zoning, the indirect lightning data simulation and the protection design for lightning indirect effects of equipment by lightning strike for unmanned aircraft consisting of composite wings. Through the analysis of lightning strike zoning according to the external shape of unmanned aerial vehicles, the structure areas that should be protected during lightning strike is derived, and the protection requirements of lightning indirect effects for flight critical equipments and equipment that must be operated upon lightning strike was derived. Lightning protection levels according to the location of mounting equipment and surrounding structure materials for each equipment was derived, and the protection design of the unmanned aerial vehicle with composite structures was also proposed from direct effect of lightning. Later, the lightning protection technology will be verified by the ground test of lightning direct and indirect effects.

즉시 상아질 봉쇄와 지연 상아질 봉쇄에 따른 상아질 접착의 미세인장 결합강도 비교 (The comparison of microtensile bond strength with immediate and delayed dentin sealing)

  • 이흥배;한종현;심준성;김선재
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.372-380
    • /
    • 2008
  • 연구목적: 본 연구의 목적은 즉시 상아질 봉쇄 (immediate dentin sealing; IDS)을 시행한 경우와 지연 상아질 봉쇄 (delayed dentin sealing ; DDS)를 시행한 경우를 비교하고, 지연 상아질 봉쇄 시 상아질 접착제를 먼저 중합한 경우와 복합레진과 함께 중합한 경우에 있어서 상아질과 복합레진의 결합강도를 비교하는 것이다. 재료 및 방법: 사람의 건전한 대구치 20개의 치관부를 삭제하여 상아질 표면을 노출시켰다. 상아질 접착 후 바로 복합레진을 축조하는 과정에서 군을 4 가지로 나누었다. 대조군은 주수 하에 model trimmer를 이용하여 치관부 삭제 후 바로 2-step etch-and-rinse dentin bonding agent (ONE-STEP, Bisco, USA)를 이용하여 상아질 접착을 시행하고 복합레진 (RENEW, Bisco, USA)을 수복하였다. 실험군 A는 치아 삭제 후, Fermit을 이용한 임시수복 상태로 5일간 생리식염수에 보관하였다. 임시수복 제거 후 상아질 접착제를 도포하고 별도의 중합없이 레진을 축조하고 함께 중합하였다. 실험군 B는 치아 삭제 후, 상아질 접착제 도포 및 중합하고 임시수복을 시행하여 5일간 생리식염수에 보관하였다. 임시수복 제거 후 상아질 접착제를 도포하고 별도의 중합없이 레진을 축조하고 함께 중합하였다. 실험군 C는 치아 삭제 후, 임시수복 상태로 5일간 생리식염수에 보관하였다. 임시수복 제거 후, 상아질 접착제를 도포 및 중합하고, 레진을 축조 및 중합하였다. 각 치아를 단면적 1 $mm^2$, 길이 10-12 mm의 막대형 시편으로 절단하여, 미세인장 결합강도를 측정하였다. 측정된 결합강도는 one-way ANOVA를 이용하여 비교 분석하였으며, 사후 검증은 Scheffe test를 이용하여 분석하였다. 연구결과: 본 실험의 결과는 다음과 같다. 1. 치아 삭제 후 별도의 상아질 접착 시행 없이 임시수복하고, 레진 축조 전 상아질 접착을 도포 후 별도의 중합과정 없이 레진과 함께 중합할 경우, 상아질과의 미세인장 결합강도는 유의하게 낮은 값을 보였다 (P < .01). 2. 치아 삭제 및 임시 수복 기간 후, 상아질 접착제를 먼저 중합하고 복합 레진을 수복하는 경우와 치아 삭제 후 상아질 접착을 시행하고 수복물 장착 시 상아질 접착을 재시행하는 경우 간의 상아질에 대한 결합강도의 차이는 없었다 (P > .05).

치과용 접착제가 복합레진 인레이와 레진시멘트의 결합력에 미치는 영향 (INFLUENCE OF ADHESIVE APPLICATION ON SHEAR BOND STRENGTH OF THE RESIN CEMENT TO INDIRECT RESIN COMPOSITE)

  • 송미혜;박수정;조현구;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.419-427
    • /
    • 2008
  • 본 연구는 레진시멘트의 레진인레이에 대한 접착 시 접착제 혹은 primer의 사용이 결합력에 영향을 미치는지 평가하기 위해 시행하였다. 직경 5mm,높이 4.5mm의 원기둥 형태로 제작한 레진인레이 (Tescera, Bisco, USA)의 표면을 1000번, 1500번 그리고 2000번 사포로 주수 하에서 연마하여 평편한 면을 형성한 후 레진인레이의 표면에 sandblasting을 시행한 후 표면에 1분 동안 silane을 도포하였다. 2군으로 나누어 한 군은 대조군으로, 다른 한 군은 표면에 동일한 제조사의 접착제나 프라이머를 도포한 후 중합하였다. 레진인레이 상에 3mm 직경의 구멍이 형성된 아크릴판을 고정하고, 구멍에 레진 시멘트를 주입하여 경화시켰다. 레진 시멘트는 Panavia-F (Kurary), Varolink-II(Ivoclar-Vivadent), RelyX Unicem(3M ESPE), Duolink(Bisco)와 자가중합형인 Multilink (Ivoclar-Vivadent)를 사용하였다. 제작된 시편을 만능물성시험기에 위치시고 전단결합강도를 측정하였다. 측정 결과 접착제나 프라이머를 도포한 군은 대조군에 비해 전단결합강도가 증가하였다 (p<0.05). 하지만 Variolink-II와 Panavia-F는 전단결합강도의 차이를 보이지 않았다. 대조군에서는 각 레진 시멘트간에 전단결합강도의 유의한 차이를 보였으며 (p<0.01) Variolink-II가 가장 높은 결합강도를 보인 반면, 자가중합형인 Multilink가 가장 낮은 결합강도를 보였다. 하지만, 접착제나 프라이머를 도포한 군에서는 각 제품간에 전단결합강토의 차이를 보이지 않았다. 이상의 결과 이원중합형이나 자가중합형 레진시멘을 이용하여 레진인레이 부착 시 silane 처리 후 접착제나 프라이머의 도포가 결합 강도의 증가를 위해 필요하리라 사료된다.

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

  • Park, Jae-Hyun;Choi, Jin-Young;Kim, Seong-Hun;Kim, Su-Jung;Lee, Kee-Joon;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제51권6호
    • /
    • pp.375-386
    • /
    • 2021
  • Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient's dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.

신발제조업체의 접착제 사용에 따른 직접·간접폭로 근로자들의 복합유기용제 폭로량과 자각증상 비교 (A Study on the Mixed Organic Solvent Dose and Subjective Symptoms of Direct and Indirect Bonding workers in Shoes Manufacturing Industrial)

  • 변정식;김정윤;조영채;김동현
    • 한국산업보건학회지
    • /
    • 제5권1호
    • /
    • pp.48-58
    • /
    • 1995
  • This study was performed to find out the exposure level of mixed organic solvents, excretion of urinary hippuricacid and subjective symptoms according to the exposure of organic solvents of female workers who works on 5 shoes manufacturing industries in Taejon City from 24, september to 20, october 1993. The studied groups were divided into 3 groups that were consist of direct exposure group(48 workers), indirect exposure group(49 workers) and non-exposure group(68 workers) to the organic solvents. The exposure levels of toluene of direct exposure group which $89.86{\pm}56.20ppm$ had higher than that of indirect exposure group which had $40.23{\pm}47.21ppm$. In the exposure level of mixed organic solvent(R-value), direct exposure group was $2.84{\pm}1.53$ and exceeded approximatly 3 times the R-value. Whereas, indirect exposure group was not exceeded the R-value as $0.80{\pm}0.61$. In the excretion level of urinary hippuric acid, direct exposure group was $1.78{\pm}1.25g/l$, indirect exposure group was $1.22{\pm}0.93g/l$ and non-exposure group was $0.51{\pm}0.18g/l$ respectively. Therefore both direct exposure group and indirect exposure group were significantly higher than non-exposure group(P<0.01). In the correlation between toluene levels and urinary hippuric acid level, the direct exposure group had positive correlation(R=0.8309, P<0.01), also indirect exposure group had positive correlation(R=0.5859, P<0.05) and also in the correlation between the R value of mixed organic solvents and the urinary hippuric acid levels, the direct exposure group had positive correlation(R=0.4492, P<0.05), and indirect exposure group had ositive correlation(R=0.7911, P<0.01). In the complain rates of the worker's subjective symptoms at work, both direct exposure group and indirect exposure group were higher than non-exposure group(P<0.05, P<0.01). But the sujective symptoms of "floating sensation" of direct exposure group had significantly higher than indirect exposure group. In the percent of subjective symptoms complaints during the worker's daily life, both direct exposure group and indirect exposure group had generally more statistical significance than nonexposure group(P<0.01), direct exposure group had not statistical significant difference from indirect exposure group. As the results mentioned above, it has been analysed that the indirect at the adjacent manufaturing process are exposed to the considerable amount of solvent. Therefore, I think that there should be the betterment of surrounding through the complete working environment management to the occurrence source of the organic solvent, the changes of health management system to the indirect-exposed workers, and the systematic management of the special medical examination and the like.

  • PDF

부가적 부식 과정이 단일 접착 과정 레진 시멘트의 접착 강도에 미치는 영향 (EFFECT OF THE ADDITIONAL ETCHING PROCEDURE ON PUSH-OUT BOND STRENGTH OF ONE-STEP RESIN CEMENT)

  • 강순일;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.443-451
    • /
    • 2008
  • 이 연구의 목적은 단일 접착 과정의 레진 시멘트인 Maxcem을 제조사의 지시대로 사용하는 것과 부가적인 산 부식과정을 추가하여 접착을 시도함에 있어 그 임상적 접착 강도를 알아보고자 하는 것이었다. 치아 우식에 이환되지 않은 120개의 상하악 구치를 사용하여 간접 수복물 제작을 위한 와동을 형성하고 금인레이와 간접복합레진(Synfony) 수복물을 제작하였다. 실험군은 수복물의 종류마다 사용한 시멘트의 종류와 방식에 따라 세 군으로 분류하였다. 최종적으로 102개의 와동 시편에 수복물의 접착을 위해 Maxcem을 사용한 군, 인산으로 부가적인 산부식 후에 Maxcem을 사용한 군, 그리고 대조군으로 다단계 전-산부식 (total-etching) 시멘트인 Variolink II 를 사용하여 접착한 실험군으로 각 군 당 17개씩으로 분류하였다. 자체 제작한 만능시험기로 push-out 접착 강도를 측정하고 와동 접착 표면적으로 나누어 단위 면적당 결합력으로 산출하였다. SPSS 12.0K 프로그램을 사용하여 one-way ANOVA와 95% 신뢰도의 Scheffe's Test로 각 실험군의 접착력를 비교하였다. 이 실험의 조건하에서는 Maxcem을 사용할 때, 간접수복물의 종류에 관계없이, 제조사의 지시 외에 부가적인 산부식 과정은 접착 강도를 감소시키는 역효과를 유발하였으며 더욱 강한 접착력을 필요로 하는 경우는 다단계 접착제를 사용하여 산부식 과정과 접착제 적용, 시멘트 도포 등을 분리하여 사용하는 것이 바람직하다.

Microtensile bond strength of repaired indirect resin composite

  • Visuttiwattanakorn, Porntida;Suputtamongkol, Kallaya;Angkoonsit, Duangjai;Kaewthong, Sunattha;Charoonanan, Piyanan
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.38-44
    • /
    • 2017
  • PURPOSE. The objective of this study was to investigate the effect of surface treatments on microtensile bond strengths (MTBSs) of two types of indirect resin composites bonded to a conventional direct resin composite. MATERIALS AND METHODS. Indirect resin composite blocks of Ceramage and SR Nexco were prepared in a plastic mold having a dimension of $10{\times}10{\times}4\;mm$. These composite blocks were divided into three groups according to their surface treatments: Group1: Sandblast (SB); Group2: Sandblast and ultrasonically clean (SB+UL); Group3: Sandblast plus silane (SB+SI). After bonding with direct resin composite, indirect-direct resin composite blocks were kept in distilled water for 24 hours at $37^{\circ}C$ and cut into microbars with the dimension of $1{\times}1{\times}8\;mm$. Microbar specimens (n = 40 per group) were loaded using a universal testing machine. Failure modes and compositions were evaluated by SEM. The statistical analyses of MTBS were performed by two-way ANOVA and Dunnett's test at ${\alpha}=.05$. RESULTS. Surface treatments and brands had effects on the MTBS without an interaction between these two factors. For SR Nexco, the MTBSs of SB and SB+SI group were significantly higher than that of SB+UL. For Ceramage, the MTBSs of SB and SB+SI were significantly higher than that of SB+UL. The mean MTBS of the Ceramage specimens was significantly higher than that of SR Nexco for all surface treatments. CONCLUSION. Sandblasting with or without silane application could improve the bond strengths of repaired indirect resin composites to a conventional direct resin composite.

Experimental investigation on CFRP-to-concrete bonded joints across crack

  • Anil, Ozgur;Belgin, Cagatay M.;Kara, M. Emin
    • Structural Engineering and Mechanics
    • /
    • 제35권1호
    • /
    • pp.1-18
    • /
    • 2010
  • Bonding of carbon fiber reinforced polymer (CFRP) composites has become a popular technique for strengthening concrete structures in recent years. The bond stress between concrete and CFRP is the main factor determining the strength, rigidity, failure mode and behavior of a reinforced concrete member strengthened with CFRP. The accurate evaluation of the strain is required for analytical calculations and design processes. In this study, the strain between concrete and bonded CFRP sheets across the notch is tested. In this paper, indirect axial tension is applied to CFRP bonded test specimen by a four point bending tests. The variables studied in this research are CFRP sheet width, bond length and the concrete compression strength. Furthermore, the effect of a crack- modeled as a notch- on the strain distribution is studied. It is observed that the strain in the CFRP to concrete interface reaches its maximum values near the crack tips. It is also observed that extending the CFRP sheet more than to a certain length does not affect the strength and the strain distribution of the bonding. The stress distribution obtained from experiments are compared to Chen and Teng's (2001) analytical model.

An effect of immediate dentin sealing on the shear bond strength of resin cement to porcelain restoration

  • Choi, Yu-Sung;Cho, In-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권2호
    • /
    • pp.39-45
    • /
    • 2010
  • PURPOSE. The aim of this study was to determine differences in shear bond strength to human dentin using immediate dentin sealing (IDS) technique compared to delayed dentin sealing (DDS). MATERIALS AND METHODS. Forty extracted human molars were divided into 4 groups with 10 teeth each. The control group was light-cured after application of dentin bonding agent ($Excite^{(R)}$ DSC) and cemented with $Variolink^{(R)}$. II resin cement. IDS/SE (immediate dentin sealing, $Clearfil^{TM}$ SE Bond) and IDS/SB (immediate dentin sealing, $Adapter^{TM}$ Single Bond 2) were light-cured after application of dentin bonding agent ($Clearfil^{TM}$ SE Bond and $Adapter^{TM}$ Sing Bond 2, respectively), whereas DDS specimens were not treated with any dentin bonding agent. Specimens were cemented with $Variolink^{(R)}$. II resin cement. Dentin bonding agent ($Excite^{(R)}$. DSC) was left unpolymerized until the application of porcelain restoration. Shear strength was measured using a universal testing machine at a speed of 5 mm/min and evaluated of fracture using an optical microscope. RESULTS. The mean shear bond strengths of control group and IDS/SE group were not statistically different from another at 14.86 and 11.18 MPa. Bond strength of IDS/SE group had a significantly higher mean than DDS group (3.14 MPa) (P < .05). There were no significance in the mean shear bond strength between IDS/SB (4.11 MPa) and DDS group. Evaluation of failure patterns indicates that most failures in the control group and IDS/SE groups were mixed, whereas failures in the DDS were interfacial. CONCLUSION. When preparing teeth for indirect ceramic restoration, IDS with $Clearfil^{TM}$ SE Bond results in improved shear bond strength compared with DDS.