• 제목/요약/키워드: Indian design

검색결과 347건 처리시간 0.025초

Analysis of the Foam Generated Using Surfactant Sodium Lauryl Sulfate

  • Ranjani, G. Indu Siva;Ramamurthy, K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제4권1호
    • /
    • pp.55-62
    • /
    • 2010
  • The performance evaluation of a sodium lauryl sulfate to qualify as a foaming agent is presented in this paper. When new surfactants are used a systematic study of production parameters on the foam characteristics needs to be undertaken unlike proprietary foaming agents and foam generator for which manufacturer has predefined the parameters. The relative influence of the foam parameters and optimization of factors were carried out through a systematic experiment design. The foam production parameters namely foam generation pressure and dilution ratio of foaming agents are observed to have significant effect on all foam characteristics with the exception of foam output rate on which only foam generation pressure has influence. The foam with good initial foam density need not necessarily be stable foam. The optimum levels of foam production parameters are determined for the surfactant Sodium lauryl sulfate which can be used to produce stable foam for foam concrete production.

Two-loop Hysteretic Control of $3^{rd}$ Order Buck Converter

  • Veerachary, M.;Sharma, Deepen
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.310-317
    • /
    • 2007
  • In this paper, an analysis and hysteretic controller design of a $3^{rd}$ order buck converter is presented. The proposed hysteretic controller consists of an inner current-loop, just like the conventional cascade control scheme, and an outer voltage-loop for load voltage regulation. Although it is possible to include an inner current loop from different branches of the converter, from the feasibility and operational point of view, the load side capacitor current would be the better choice. The addition of an inner current-loop improves the dynamic performance of the converter while preserving the robustness of the hysteretic control. The controller formulation and closed-loop converter performance analysis are validated through computer simulations. Few experimental results of the proposed converter are given and compared with the buck converter.

Analysis of Kinetic Data of Pectinases with Substrate Inhibition

  • Gummadi, Sathyanarayana-N.;Panda, T.
    • Journal of Microbiology and Biotechnology
    • /
    • 제13권3호
    • /
    • pp.332-337
    • /
    • 2003
  • Enzyme kinetics data play a vital role in the design of reactors and control of processes. In the present study, kinetic studies on pectinases were carried out. Partially purified polymethylgalacturonase (PMG) and polygalacturonase (PG) were the two pectinases studied. The plot of initial rate vs. initial substrate concentration did not follow the conventional Michaelis-Menten kinetics, but substrate inhibition was observed. For PMG, maximum rate was attained at an initial pectin concentration of 3 g/l, whereas maximum rate was attained when the initial substrate concentration of 2.5 g/l of polygalacturonic acid for PG I and PG II. The kinetic data were fitted to five different kinetic models to explain the substrate inhibition effect. Among the five models tested, the combined mechanism of protective diffusion limitation of both high and inhibitory substrate concentrations (semi-empirical model) explained the inhibition data with 96-99% confidence interval.

A Distribution Automation System Simulator for Training and Research

  • Gupta R. P.;Srivastava S. C.
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.159-170
    • /
    • 2005
  • This paper presents the design and development of a scaled down physical model for power Distribution Automation (DA) system simulation. The developed DA system simulator is useful in providing hands-on experience to utility engineers / managers to familiarize with the DA system and gain confidence in managing the power distribution system from the computer aided distribution control center. The distribution automation system simulator can be effectively used to carry out further research work in this area. This also helps the undergraduate and graduate students to understands the power distribution automation technology in the laboratory environment. The developed DA simulator has become an integral part of a distribution automation lab in the Electrical Engineering Department at Indian Institute of Technology Kanpur in India.

Microstrip Coupled-Line Lowpass Filter with Wide Stopband for RF/Wireless Systems

  • Velidi, Vamsi Krishna;Mandal, Mrinal Kanti;Sanyal, Subrata
    • ETRI Journal
    • /
    • 제31권3호
    • /
    • pp.324-326
    • /
    • 2009
  • We present the design of a compact microstrip lowpass filter with a wide stopband which is up to ten times the cutoff frequency. The filter is based on a coupled-line configuration and shunt open stubs. The open stubs create additional transmission zeros, which are used to extend the stopband of the filter without any additional components or cascaded units. A prototype lowpass filter with a 3 dB cutoff frequency of 0.428 GHz and a 15 dB stopband extended up to 4.77 GHz is fabricated to validate the theoretical predictions.

  • PDF

A High Performance Three-Phase Telecom Supply Incorporating a HF Switched Mode Rectifier with a Phase Shifted PWM Controller

  • Shahani, Arushi;Singh, Bhim;Bhuvaneshwari, G.
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.219-227
    • /
    • 2010
  • Telecom supplies need to conform to low Total Harmonic Distortion (THD) and high Power Factor (PF) as per IEC 61000-3-2 and IEEE 519-1992 standards. These high rating power supplies use a three phase utility in which low THD and high PF are realized via various passive and active wave shaping schemes. In this paper, a new design for three phase telecom power supplies is presented with circuit parameter values optimized for high performance in terms of a low THD, high PF, low ripple and high line and load regulation using a suitable combination of various strategies. The performance of the power supply is validated by extensive simulations.

Flow Analyses Inside Jet Pumps Used for Oil Wells

  • Samad, Abdus;Nizamuddin, Mohammad
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권1호
    • /
    • pp.1-10
    • /
    • 2013
  • Jet pump is one type of artificial lifts and is used when depth and deviation of producing wells increases and pressure depletion occurs. In the present study, numerical analysis has been carried out to analyze the flow behavior and find the performance of the jet pump. Reynolds-averaged Navier Stokes equations were solved and k-${\varepsilon}$ turbulence model was used for simulations. Water and light oil as primary fluids were used to pump water, light oil and heavy oil. The ratios of area and length to diameter of the mixing tube were considered as design parameters. The pump efficiency was considered to maximize for the downhole conditions. It was found that the increase in viscosity and density of the secondary fluid reduced efficiency of the system. Water as primary fluid produced better efficiency than the light oil. It was also found that the longer throat length increased efficiency upto 40% if light oil was used as primary fluid and secondary fluid viscosity was 350 cSt.

객차용 BOOST형 보조전원장치에 관한 연구 (Development of the Boost Type Auxiliary Coach Converter)

  • 김태완;박건태;정기찬;이성목;김두식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.727-732
    • /
    • 2000
  • This paper is on the development of a auxiliary power supply for the coach of Indian Railways. The auxiliary power supply system supplies the power for air-conditioners, air-compressors, lighting equipments, controllers, etc. It converts the input voltage, DC 110V which is supplied from battery, to AC 3${\Phi}$ 415V of 30kVA capacity. This is a low voltage-high current type converter system and largely consists of boost chopper and 3 phase inverter. Adopting a optimal control algorithm and simple power circuit, we realized the more reliable and competitive system for satisfaction of Indian Railway's strict requirement for vibration, temperature and dust. We completed the design, the manufacture and the field test of the system successfully and proved the system performance and reliability as a result of those tests.

  • PDF

Analog CMOS Performance Degradation due to Edge Direct Tunneling (EDT) Current in sub-l00nm Technology

  • Navakanta Bhat;Thakur, Chandrabhan-Singh
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제3권3호
    • /
    • pp.139-144
    • /
    • 2003
  • We report the results of extensive mixed mode simulations and theoretical analysis to quantify the contribution of the edge direct tunneling (EDT) current on the total gate leakage current of 80nm NMOSFET with SiO2 gate dielectric. It is shown that EDT has a profound impact on basic analog circuit building blocks such as sample-hold (S/H) circuit and the current mirror circuit. A transistor design methodology with zero gate-source/drain overlap is proposed to mitigate the EDT effect. This results in lower voltage droop in S/H application and better current matching in current mirror application. It is demonstrated that decreasing the overlap length also improves the basic analog circuit performance metrics of the transistor. The transistor with zero gate-source/drain overlap, results in better transconductance, input resistance, output resistance, intrinsic gain and unity gain transition frequency.

Numerical Analysis of Centrifugal Impeller for Different Viscous Liquids

  • Bellary, Sayed Ahmed Imran;Samad, Abdus
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권1호
    • /
    • pp.36-45
    • /
    • 2015
  • Oil and gas industry pumps viscous fluids and investigation of flow physics is important to understand the machine behavior to deliver such fluids. 3D numerical flow simulation and analysis for different viscous fluids at different rotational speeds of a centrifugal impeller have been reported in this paper. Reynolds-averaged Navier Stokes (RANS) equations were solved and the performance analysis was made. Standard two equation k-${\varepsilon}$ model was used for the turbulence closure of steady incompressible flow. An inlet recirculation and reverse flow in impeller passage was observed at low impeller speeds. It was also found that the higher viscosity fluids have higher recirculation which hinders the impeller performance.