• 제목/요약/키워드: Index of Volume

검색결과 1,439건 처리시간 0.027초

유방조직의 밀도와 체질량지수와의 상관관계 (Correlation of Breast Tissue Density and Body Mass Index)

  • 양정학;이택종
    • Archives of Plastic Surgery
    • /
    • 제37권6호
    • /
    • pp.732-735
    • /
    • 2010
  • Purpose: In performing breast reconstruction, making symmetrical breast is still a challenge. A precise estimate of the volume of the breast specimen is necessary to reconstruct a symmetrical and aesthetically pleasing breast. This study aims at finding out the relationship with breast tissue density and body mass index designed to apply for breast reconstruction. Methods: By using the Archimedes' principle, the authors calculated the volume of the breast specimen and drew a correlation between the density of breast specimen and BMI. From October 2002 to November 2004, this method was used on 197 patients to predict breast volume for TRAM flap reconstruction. Results: The mean density was 0.9954g/cc and had no correlation with BMI (p-value=0.069). There was no difference between denstiy of breast tissue after skin spared mastectomy and that of breast tissue after nipple spared mastectomy. Conclusion: These data will be helpful to predict the needed volume for breast reconstruction.

Comparison of plan dosimetry on multi-targeted lung radiotherapy: A phantom-based computational study using IMRT and VMAT

  • Khan, Muhammad Isa;Rehman, Jalil ur;Afzal, Muhammad;Chow, James C.L.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3816-3823
    • /
    • 2022
  • This work analyzed the dosimetric difference between the intensity modulated radiotherapy (IMRT), partial/single/double-arc volumetric modulated arc therapy (PA/SA/DA-VMAT) techniques in treatment planning for treating more than one target of lung cancer at different isocenters. IMRT and VMAT plans at different isocenters were created systematically using a Harold heterogeneous lung phantom. The conformity index (CI), homogeneity index (HI), gradient index (GI), dose-volume histogram and mean and maximum dose of the PTV were calculated and analyzed. Furthermore, the dose-volume histogram and mean and maximum doses of the OARs such as right lung, contralateral lung and non GTV were determined from the plans. The IMRT plans showed the superior target dose coverage, higher mean and maximum values than other VMAT techniques. PA-VMAT technique shows more lung sparing and DA-VMAT increases the V5/10/20 values of contralateral lung than other VMAT and IMRT techniques. The IMRT technique achieves highly conformal dose distribution to the target than other VMAT techniques. Comparing to the IMRT plans, the higher V5/10/20 and mean lung dose were observed in the contralateral lung in the DA-VMAT.

시간자료의 공간화를 통한 일교통량 결측대체 방법론 연구 (Missing Imputation Methodologies for Daily Traffic Counts by Transforming Time Data into Spatial Data)

  • 허태영;오주삼
    • 한국도로학회논문집
    • /
    • 제9권3호
    • /
    • pp.21-28
    • /
    • 2007
  • 본 연구에서는 결측된 일교통량의 대체를 위하여 교통공학에서 많이 활용되고 있는 기존의 선형내삽법에 공간상관성 기법을 고려한 새로운 선형내삽법을 제안하였다. 일교통량과 같이 시간적 특성을 지닌 자료를 공간위에 배치하여 공간적 상관성을 고려할 수 있도록 하였다. 공간상관성을 측정하기 위하여 일교통량의 순환성을 감안하여 같은 주의 요일간 상관성과 주별 같은 요일의 상관성을 나타내는 지표로서 Moran Index를 사용하였다. 실제 분석을 위하여 한국건설기술연구원에서 제공한 2004년 11월의 28일간의 일교통량 자료를 $4{\times}7$ 격자 형태로 배치하여 일별 교통량자료를 공간화 시켜 공간 상관성을 살펴보았으며, 여러 가지 통계적 지표를 통하여 공간 선형내삽법의 우수성을 확인하였다.

  • PDF

조선왕조실록 밀랍본 복원용지로서 전통한지의 oxidation index 분석 (The Analysis of the Oxidation Index of Korea Traditional Paper(Hanji) Which Is Used as the Rrestoration Paper of the Waxed Volume in the Annals of Joseon Dynasty)

  • 서진호;정소영;정선화
    • 펄프종이기술
    • /
    • 제40권1호
    • /
    • pp.55-61
    • /
    • 2008
  • The annals of Joseon Dynasty is the most valuable resource containing the record of Korean history and has been known as one of the UNESCO's Memory of the World Register. In some period, wax-treated paper was used in the annals of Joseon Dynasty to prevent the damage from pests. But, wax-treated volumes were discolored to brown, white or black, and partially cracked by the stiffened wax. It means that wax-treated volumes were damaged by the hardening and oxidizing of wax. The wax is considered as the first reason in damages on the wax-treated volume. Therefore, in this study we analysed the oxidation index of Korea traditional paper(Hanji) which is used as the restoration paper of the waxed volume in the annals of Joseon Dynasty by using FT-IR. As the analysis of FT-IR, the traditional two-layed stamping paper (Hanji sample F), which was treated by starch in its surface, was shown the most stable state after the accelerated ageing test.

비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가 (Evaluation of Dose Volume and Radiobiological Indices by the Dose Calculation Grid Size in Nasopharyngeal Cancer VMAT)

  • 강동진;정재용;신영주;민정환;심재구;박소현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.265-272
    • /
    • 2020
  • The purpose of this study was to investigate the dose-volume indices and radiobiological indices according to the change in dose calculation grid size during the planning of nasopharyngeal cancer VMAT treatment. After performing the VMAT treatment plan using the 3.0 mm dose calculation grid size, dose calculation from 1.0 mm to 5.0 mm was performed repeatedly to obtain a dose volume histogram. The dose volume index and radiobiological index were evaluated using the obtained dose volume histogram. The smaller the dose calculation grid size, the smaller the mean dose for CTV and the larger the mean dose for PTV. For OAR of spinal cord, brain stem, lens and parotid gland, the mean dose did not show a significant difference according to the change in dose calculation grid size. The smaller the grid size, the higher the conformity of the dose distribution as the CI of the PTV increases. The CI and HI showed the best results at 3.0 mm. The smaller the dose calculation grid size, the higher the TCP of the PTV. The smaller the dose calculation grid size, the lower the NTCP of lens and parotid. As a result, when performing the nasopharynx cancer VMAT plan, it was found that the dose calculation grid size should be determined in consideration of dose volume index, radiobiological index, and dose calculation time. According to the results of various experiments, it was determined that it is desirable to apply a grid size of 2.0 - 3.0 mm.

유방암 환자의 3D-CRT, TOMO 방법에 따른 선량 분포 평가 (Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer)

  • 김대웅;김종원;최윤경;김정수;황재웅;정경식;최계숙
    • 대한방사선치료학회지
    • /
    • 제20권1호
    • /
    • pp.11-15
    • /
    • 2008
  • 목 적: 방사선치료계획에 있어서 정상조직과 치료부위의 선량 분포는 매우 중요하다. 이에 본원에서는 유방암 환자를 대상으로 Three-dimensional conformal radiation therapy (3D-CRT), Helical tomotherapy (TOMO)의 방법으로 방사선치료계획을 세웠으며 이에 선량분포를 분석하여 실제 임상에서의 적용여부를 알아보고자 한다. 대상 및 방법: 20명의(좌측: 10명, 우측: 10명) 유방보존절제술 환자를 대상으로 시행하였으며 방법으로는 같은 조건에서 3D-CRT는 Philips사의 Pinnacle을, TOMO는 TomoTherapy사의 TOMO Planning System을 이용해 치료계획을 세웠다. Dose-Volume Histogram (DVH)의 prescribed dose (PD)에 대한 PTV의 Homogeneity index (HI)와 Conformity index (CI)를 구하였고, 정상조직의 dose- volume 관계를 비교하였다. 결 과: Homogeneity index (HI)와 Conformity, index (CI)는 TOMO에서 우수한 결과를 나타났다. $V_{-50-IB-NPTV}$ (the percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose)는 3D-CRT: 40.4%, TOMO: 18.3%, $V_{20-IL}$ (the average ipsilateral lung volume percentage receiving 20% of the prescribed dose)는 3D-CRT: 4.8%, TOMO: 14.2%, $V_{20-10H}$ (the average heart volume percentage delivered 20% and 10% of the prescribed dose in left breast cancer)는 3D-CRT: 1.6%, 3% TOMO: 9.7%, 26.3%의 결과를 보여준다. 결 론: 유방암 환자의 방사선치료계획 방법들은 PTV에서 원하는 선량분포를 보여줬다. 그러나 TOMO는 좋은 Homogeneity index (HI), Conformity index (CI)와 Breast를 보호하는 장점이 있는 반면에 Lung과 Heart에서는 많은 피폭선량이 있음을 알 수 있기에 TOMO의 방사선치료계획시 주의해야 할 점으로 사료된다.

  • PDF

통행거리빈도분포를 활용한 고속도로 기능 평가 개선 연구 (A study on improving the evaluation of motorway functions using Trip Length Frequency Distribution(TLFD))

  • 권철우;윤병조
    • 도시과학
    • /
    • 제11권2호
    • /
    • pp.9-17
    • /
    • 2022
  • The purpose of this study is to develop an index for evaluating the function of a new motorway using the travel distance frequency distribution (TLFD) calculated using the vehicle travel route big data, and to overcome the limitations of the evaluation through the existing traffic volume. The mobility evaluation index of motorways was developed by applying it to the TLFD data table in 2019. The smaller the value of the mobility evaluation index of the link is calculated, the more it is a link with mainly short-distance travel, and the higher the value of the mobility evaluation index, the more it means a link with mainly long-distance travel. The accessibility evaluation index was calculated through the result of the mobility evaluation index of all motorways developed, and all motorways were grouped into three groups using K-means clustering. Group A was found to exist inside a large city and consisted of motorways with many short-distance traffic, Group B was investigated as acting as an arterial between groups, and Group C was classified as a motorway consisting mainly of long-distance traffic connecting large cities and large cities. This study is significant in developing a new motorway function evaluation index that can overcome the limitations of motorway function evaluation through the existing traffic volume. It is expected that this study can be a reasonable comprehensive indicator in the operation and planning process of motorways.

두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향 (The Effect of Volume Reduction on Computed Treatment Planning during Head and Neck IMRT and VMAT)

  • 엄기천;김가중;백금문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.239-246
    • /
    • 2023
  • In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom's body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

Effect of power law index for vibration of armchair and zigzag single walled carbon nanotubes

  • Khadimallah, Mohamed Amine;Hussain, Muzamal
    • Steel and Composite Structures
    • /
    • 제37권5호
    • /
    • pp.621-632
    • /
    • 2020
  • This research deals with the study of vibrational behavior of armchair and zigzag single-walled carbon nanotubes invoking extended Love shell theory. The effects of different physical and material parameters on the fundamental frequencies are investigated. By using volume fraction for power law index, the fundamental natural frequency spectra for two forms of single-walled carbon nanotubes are calculated. The influence of frequencies against length-to-diameter ratios with varying power law index are investigated in detail for these tubes. To discretize the governing equation in eigen-value form, wave propagation approach is developed. Complex exponential functions have been used and the axial model depends on boundary condition that has been described at the edges of carbon nanotubes to calculate the axial modal dependence. Computer software MATLAB is utilized for the frequencies of single-walled carbon nanotubes and current results shows a good stability with comparison of other studies.

Analysis of cross-talk effects in volume holographic interconnections using perturbative integral expansion method

  • Jin, Sang-Kyu
    • Journal of the Optical Society of Korea
    • /
    • 제2권2호
    • /
    • pp.58-63
    • /
    • 1998
  • Cross-talk effects in high-density volume holographic interconnections are investigated using perturbative iteration method of the integral form of Maxwell's wave equation. In this method, the paraxial approximation and negligence of backward scattering introduced in conventional coupled mode theory is not assumed. Interaction geometries consisting of non-coplanar light waves and multiple index gratings are studied. Arbitrary light polarization is considered. Systematic analysis of cross-talk effects due to multiple index gratings is performed in increasing level of diffraction orders corresponding to successive iterations. Some numerical examples are given for first and third order diffraction.