• Title/Summary/Keyword: Index ion

Search Result 197, Processing Time 0.03 seconds

Electrochemical Properties of Kaolinite in Aqueous Suspension (수용액중(水溶液中)에서의 Kaolinite 입자(粒子)의 전기화학적(電氣化學的) 성질(性質))

  • Lim, Hyung-Sik;Baham, J.;Volk, V.V.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.16 no.4
    • /
    • pp.318-324
    • /
    • 1983
  • Electrochemical properties of Georgia kaolinite in aqueous suspension were studied by ion adsorption, potentiometric titration, and electrophoretic mobility measurements. Kaolinite in 0.001 M and 0.1 M NaCl solution showed qualitatively both pH independent and pH depender negative and positive charges through pH range 2.5-11.0 when dissolved aluminum ions from kaolinite were considered as well as $Na^+$ and $Cl^-$ as index ions. Electrophoretic mobilities (EM) of 0.02 wt. % kaolinite suspension in distilled water and 0.001 M NaCl solution were approximately constant against mobility measuring time consumed in the electrophoresis cell at different pH values, and isoelectric points(IEP) were around pH 4.7. EM values in 0.1 M NaCl solution were positive and constant against mobility measuring time below pH 4; but above pH 4, EM values were negative for the first 10 seconds followed by positive values which became approximately constant through stepped changes after 10 minutes. Hydrated cations may bind to the six- member oxygen ring sites having multiple partial negative charges on the exterior tetrahedral layer surface by both electrostatic and hydrogen bonding force while hydrated anions bind to the partially positively charged hydrogen atoms on the exterior octahedral layer surface. Parts of the aluminol groups on the exterior octahedral layer surface as well as edge faces may be involved in complex reactions and have both anion and cation exchange capacities in the electrolyte solution above pH 4.

  • PDF

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

Effects of Formula (JR-22) Maybe Containing Traditional Herbs on Maximal Exercise Performance and Antioxidant Meterials in Murine Model (생약조성물 투여가 지구력 향상과 항산화 물질에 미치는 영향)

  • 홍성길;양동식;강봉주;이홍석;윤유식
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.7
    • /
    • pp.1076-1081
    • /
    • 2003
  • The effects of dietary supplementation of JR-22, formula containing distilled extracts of traditional herbs on maximal exercise performance and endurance were evaluated in mouse and rat model. In acute forced swimming test with 4%∼8% of the body weight attached to the tail, it was shown that dietary JR-22 supplementation increased endurance in exercise performance. There was no change of blood lactic acid, ammonia, inorganic phosphorous ion and creatine kinase activity, however ATP concentration in muscle was increased by JR-22 supplementation. Also, insulin-like growth factor-l (IGF-1) concentration in blood was significantly increased by JR-22 supplementation. In addition, the oxidative damage induced by exercise was reduced by JR-22 supplementation. In these results, we suggested that JR-22 supplementation enhanced maximal endurance exercise performance by the mechanism of increasing ATP and IGF-1 concentration and reducing oxidative damage.

Effects of Submersion Aging in Chilled Water on Tenderness and Microbial Growth of Vacuum-Packed Hanwoo Meat (냉수침지 숙성법이 진공포장 한우육의 연도 및 미생물 증식에 미치는 효과)

  • 주선태;이한기;강근호;신철우;양한술;문성실;이정일;김영환;박구부
    • Food Science of Animal Resources
    • /
    • v.22 no.3
    • /
    • pp.228-233
    • /
    • 2002
  • To investigate the effects of submersion aging in chilled water on tenderness and microbial growth of vacuum-packed beef, the semimembranosus muscles of Hanwoo (Korean cattle) was sampled at a commercial meat plant at 24 hrs postmortem. The samples were cut to 2.5 cm thick steaks and randomly assigned to following two treatments. The samples were stored in conventional refrigerator at 4$^{\circ}C$ after vacuum packaging for control whereas the other vacuum-packed samples were submersed in chilled water at 1$^{\circ}C$ for treatment, and both samples were stored for 14 days to measure total plate counts (TPC), sarcomere length, free calcium concentration, shear farce value and myofibrillar fragmentation index (MFI). The sarcomere length of treatment was significantly (p<0.05) longer than that of control at 3 days aging. Result suggested that submersion in chilled water of vacuum-packed beef might be effective to improve tenderness of meat compared to storage in conventional refrigerator. There were no significant differences in the shear force and MFI between control and treatment during storage. However, the free calcium concentration of samples from treatment was significantly (p<0.05) higher than that of control at 7 days of ageing. This result indicated that the lower shear force value and the longer sarcomere length of samples from treatment might be due to increasing the free calcium ion concentration in sarcoplasm during storage. On the other hands, samples from control showed significantly (p<0.05) higher number of microbial (TPC) compared to treatment during storage. from results obtained, submersion in chilled water of vacuum-packed beef could be recommended as a desirable aging method to improve tenderness of Hanwoo compared to aging in conventional refrigerator.

Design and deposition of two-layer antireflection and antistatic coatings using a TiN thin film (TiN 박막을 이용한 2층 무반사 코팅의 설계 및 층착)

  • 황보창권
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.5
    • /
    • pp.323-329
    • /
    • 2000
  • In this study we have calculated an ideal complex refractive index of a TiN trim used in a layer of anl1reilecnon (I\R) coatmg, [air$ISiO_2ITiNIglass$] in the visible. Also we simulated the rellectance of lwo-layer AR coating by varying the thicknesses of TiN and $SiO_2$ layers, respecl1vely. The simolation results show that we can controllhe lowest reflectance and AR band of tile AR coating. The TIN fihns were fabricated by a RF magnetron sputtering apparalus. The chemical, structural and electrical properties of TiN fih11S were inveshgated by the Rutherford backscattering spech'oscopy (RBS), atomic force microscope (AFM) and 4-point probe. The optical properlies were inve,tigated by the spectrophotometer and vanable angle spectroscopic ellipsometer (VASE). The smface roughness of TiN flhns \vas $9~10\AA$. TIle resistivity of TiN films was TEX>$360~730\mu$\Omega $ cm. The ,toichlOllletry of TiN film was 1'1: O:N = I: 0.65 :0.95 and ilic oxygen wa~ found on ilie smface. With these experimental and simu]al1on resulLs, we deposited duo: two-layer AR coating, [air$ISiO_2ITiNIglass$] and the refleClance was under 0.5% ill the regIOn of 440-650 run. 0 run.

  • PDF

$Na^{+}/Ca^{2+}$ Exchange System in Atrial Trabeculae and Vascular Smooth Muscle of the Rabbit (토끼 심방근 및 혈관 평활근에서의 $Na^{+}/Ca^{2+}$ 교환기전에 관한 연구)

  • Kim, Hee-Ju;Moon, Hyung-Ro;Earm, Yung-E;Ho, Won-Kyung
    • The Korean Journal of Physiology
    • /
    • v.22 no.1
    • /
    • pp.13-29
    • /
    • 1988
  • In order to elucidate the regulatory mechanism of intracellular calcium ion concentrations, contractions or contractures induced by $Na^{+}-removal$, calcium-application or ouabain-treatment as an index of $Na^+/Ca^{2+}$ exchange activity were studied in atrial muscle or vascular smooth muscle (aorta and renal artery) of the rabbit. The magnitude of low sodium contractures in atrial trabeculae increased with sigmoid shape when external sodium concentrations were reduced to sodium-free condition, whereas that of calcium contracture intensified in a parabolic pattern when external calcium concentrations were elevated to 8 mM. $Na^{+}-removal$ contractures were induced in a duration-dependent manner to $K^{+}-free$ exposure and same findings were observed with ouabain treatment. $Na^{+}-free$ contractures were not affected by verapamil treatment, but stimulated by $100{\mu}M\;Mn^{2+}$ and inhibited by high concentrations of $Mn^{2+}\;(2{\sim}8mM)$ in a dose-dependent manner. Ryanodine which is known to suppress the release of calcium from internal store abolished spontaneous twitch contractions induced by $K^{+}-free$ solution, but had no effect on the development $Na^{+}-free$ contractures. Na-free contractures were not always induced in vascular smooth muscle preparations. Contractures by $O\;mM\;Na^+$ were usually seen in aorta, but not often in renal artery.$50\;mM\;K^+$, noradrenaline (NA) and angiotensin II (AII) always evoked very large contraction in all preparations of vascular smooth muscle. Contractures developed by $O\;mM\;Na^+$ were not sensitive to verapamil treatment as in atrial trabeculae, but were abolished by $100{\mu}M\;Mn^{2+}$. In contrast to $Na^{+}-free$ contractures, $Mn^{2+}(100{\mu}M)$ had no effect on the contractures induced by NA or 50 mM$K^+$. Caffeine in the concentration of 10 mM evoked transient contracture in the distal renal artery. The rate of spontaneous relaxation in caffeine contracture was dependent upon the concentrations of external sodium, and had double component of relaxation when the rate of relaxation was plotted in the semilogarithmic scale of relative tension versus time. Especially late components of relaxation had more direct relation to $Na^+$ concentrations. It could be concluded that $Na^+/Ca^{2+}$ exchange mechanism in the heart has a large capacity, inhibited by $Mn^{2+}$ but not by verapamil and ryanodine, while $Na^+/Ca^{2+}$ exchange system in vascular smooth muscle has a very low capacity especially in small artery, inhibited by low concentration of $Mn^{2+}\;(100{\mu}M)$ but not affected by verapamil and ryanodine.

  • PDF

Influence of Ammonium Phosphate on Mycelial Morphology during Submerged Cultivation of Ganoderma lucidum (영지의 액체배양에 있어서 균사체 형태에 미치는 Ammonium Phosphate의 영향)

  • Lee, Kyu-Min;Lee, Shin-Young
    • The Korean Journal of Mycology
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2001
  • The mycelial morphology during submerged cultivation of Ganoderma ludium using by air-lift fermenter system were analyzed by image processing system and the characterization of mycelial morphology were investigated. In submerged culture using medium with different ammonium phosphate concentrations, the various morphological forms of G. lucidum mycelium were observed. The filamentous forms such as non-branched long filamentous mycelium, non-branched short mycelium, branched long filamentous mycelium, branched short mycelium, entangled mycelium and clump were observed, and also, and also, the pelleted forms such as smooth pellet, rough pellet and hollow rough pellet were observed. The mycelial morphology was changed from the filamentous to the pelleted forms by addition of ammonium phosphate. The fractal dimensions of pelleted and filamentous forms were 1.05 and 1.3, respectively, while the fractal dimension of mixtures of pelleted and filamentous forms was 1.16. Therefore, the fractal dimension was found to be more effective index for the detection of the mycelial morphology and morphological change during batch cultivation. The circularity was also found to be useful for evaluating the surface growth of pelleted mycelium.

  • PDF

Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy

  • Choi, Yona;Chun, Kook Jin;Kim, Eun San;Jang, Young Jae;Park, Ji-Ae;Kim, Kum Bae;Kim, Geun Hee;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.99-106
    • /
    • 2021
  • Purpose: In this study, we aimed to manufacture a patient-specific gel phantom combining three-dimensional (3D) printing and polymer gel and evaluate the radiation dose and dose profile using gel dosimetry. Methods: The patient-specific head phantom was manufactured based on the patient's computed tomography (CT) scan data to create an anatomically replicated phantom; this was then produced using a ColorJet 3D printer. A 3D polymer gel dosimeter called RTgel-100 is contained inside the 3D printing head phantom, and irradiation was performed using a 6 MV LINAC (Varian Clinac) X-ray beam, a linear accelerator for treatment. The irradiated phantom was scanned using magnetic resonance imaging (Siemens) with a magnetic field of 3 Tesla (3T) of the Korea Institute of Nuclear Medicine, and then compared the irradiated head phantom with the dose calculated by the patient's treatment planning system (TPS). Results: The comparison between the Hounsfield unit (HU) values of the CT image of the patient and those of the phantom revealed that they were almost similar. The electron density value of the patient's bone and brain was 996±167 HU and 58±15 HU, respectively, and that of the head phantom bone and brain material was 986±25 HU and 45±17 HU, respectively. The comparison of the data of TPS and 3D gel revealed that the difference in gamma index was 2%/2 mm and the passing rate was within 95%. Conclusions: 3D printing allows us to manufacture variable density phantoms for patient-specific dosimetric quality assurance (DQA), develop a customized body phantom of the patient in the future, and perform a patient-specific dosimetry with film, ion chamber, gel, and so on.

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.

Regression Modeling of Water-balance in Watershed (유역(流域) 물 수지(收支)의 회귀모형화(回歸模型化))

  • Kim, Tai Cheol
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.2
    • /
    • pp.324-333
    • /
    • 1983
  • Modeling of longterm runoff is theoritically based on waterbalance analysis. Simplified equation of water balance with rainfall, evapotranspiration and soil moisture storage could be formulated into regression model with variables of rainfall, pan evaporation and previous-month streamflow. The hydrologic response of water shed could be represented lumpedly, qualitatively and deductively by regression coefficients of water-balance regression model. Characteristics of regression modeling of water-balance were summarized as follows; 1. Regression coefficient $b_1$ represents the rate of direct runoff component of precipitation. The bigger the drainage area, the less $b_1$ value. This means that there are more losses of interception, surface detension and transmission in the downstream watershed. 2. Regression coefficient $b_2$ represents the rate of baseflow due to changes of soil moisture storage. The bigger the drainage area and the milder the watershed slope, the bigger b, value. This means that there are more storage capacity of watershed in mild downstream watershed. 3. Regression coefficient $b_3$ represents the rate of watershed evaporation. This depends on the s oil type, soil coverage and soil moisture status. The bigger the drainage area, the bigger $b_3$ value. This means that there are more watershed evaporation loss since more storage of surface and subsurface water would be in down stream watershed. 4. It was possible to explain the seasonal variation of streamflow reasonably through regress ion coefficients. 5. Percentages of beta coefficients what is a relative measure of the importance of rainfall, evaporation and soil moisture storage to month streamflow are approximately 89%, 9% and 11% respectively.

  • PDF