• 제목/요약/키워드: Independent load operation

검색결과 58건 처리시간 0.027초

가정용 스털링엔진 열병합발전시스템 운전특성에 관한 연구 (The Operation Characteristics of Domestic Stirling Engine Cogeneration System)

  • 최재준;박병식;정대헌
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.309-314
    • /
    • 2009
  • The unpredicted worldwide oil price makes the energy efficiency technology be more importance than any other period. The small cogeneration system is one of the most representative technology among the energy efficiency technologies, and the Stirling engine cogeneration system has been concerned and investigated due to the preferable characteristics - low toxic emission, low noise and vibration level, and the various form of fuel. A tiny, 1kW of electrical output, gas fueled Stirling engine cogeneration system was investigated. The electrical efficiency and thermal efficiency of the system were measured. The experiment was executed at an independent Stirling engine mode, independent secondary burner mode, and the combined mode. Part load characteristics of the Stirling engine cogeneration system were investigated also. With the efficiency characteristics, the $O_2$ and NOx emission characteristics were measured.

  • PDF

ATM 교환기에서 연결 정보에 대한 감사 기능 제공 방안 및 성능 평가 (Audit Method Design and Performance Evaluation for Connection Information in ATM Switch)

  • 유영일;전병실
    • 대한전자공학회논문지TC
    • /
    • 제40권11호
    • /
    • pp.27-33
    • /
    • 2003
  • 데이터 감시(AUDIT) 기능이란 분산 실장 되어 있는 데이터들을 대상으로 데이터 이상을 진단하고 불일치 데이터를 검출하여 이를 일치시키는 일련의 작업을 말하는 것으로 데이터 불일치로 인해 유발되는 시스템 문제를 최소화시키는데 목적을 둔다. 본 논문에서는 ATM 교환기의 연결 데이터의 대부분을 차지하고 있는 PVC(Permanent Virtual Circuit) 데이터에 대한 감사 기능 지원 방안을 제안하였다. 즉 고속/저속 가입자 링크에 대해 일정 시간마다 감사 기능의 주기적 수행과 운용자 명령어에 의한 즉각적인 감사 기능을 제안하여 PVC 정보의 불일치로 인한 데이터의 손실 및 시스템 장애를 최소화 할 수 있게 하였다. 또한 감사 기능으로 인해 연결 제어 프로세서와 DC(Device Controller) 사이에 송수신하는 많은 IPC(Inter Processor Communication) 메시지가 연결 제어 프로세서의 부하에 어떠한 영향을 미치는지 분석하였는데, 시스템 부하와 거의 무관하게 연결 제어 프로세서의 부하가 일정함을 확인하였다.

스마트 그리드 환경 하에서 LA사업자의 DR자원 운영 시스템 설계 (DR Resource Operation System by Load Aggregator in Smart Grid)

  • 김지희;문국현;김민경;공성배;조형철;주성관;오재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.652-653
    • /
    • 2011
  • 수요반응(DR : Demand Response)은 스마트 그리드(Smart Grid)를 구성하는 핵심 요소 중 하나이다. 본 논문에서는 스마트 그리드 환경 하에서 ISO(Independent System Operator)의 수요자원시장에 참여함과 동시에 말단 수용가들을 대상으로 다수의 DR 프로그램을 운영하는 LA(Load Aggregator)사업자의 DR자원 운영 시스템에 대한 전반적인 개념 및 흐름에 대하여 기술하였다. 또한, 스마트 그리드 하에서 LA사업자의 DR자원 운영 시스템 설계 중 LA사업자의 DR자원 최적배분 전략에 대한 개념 및 예시를 제시하였다.

  • PDF

고분자 전해질형 연료전지 자동차의 급기 시스템의 동적 모델링 및 분석 (Dyamic Modeling and Analysis of Air Supply System for Vehicular PEM Fuel Cell)

  • 장현탁
    • 한국수소및신에너지학회논문집
    • /
    • 제15권3호
    • /
    • pp.175-186
    • /
    • 2004
  • In this paper, we developed the dynamic model of a fuel cell system suitable for controller design and system operation. The transient phenomena captured in the model include the flow characteristics and inertia dynamics of the compressor, the intake manifold filling dynamics, oxygen partial pressures and membrane humidity on the fuel cell voltage. In the simulations, we paid attention to the transient behavior of stack voltage and compressor pressure, stoichiometric ratio. Simulation results are presented to demonstrate the model capability. For load current following, stack voltage dynamic characteristics are plotted to understand the Electro-chemistry involved with the fuel cell system. Compressor pressure and stoichiometric ratio are strongly coupled, and independent parameters may interfere with each other, dynamic response, undershoot and overshoot.

지하철 역사전기설비의 수용률 기준설정에 관한 연구 (A Study on the Guidelines for Demand Factor of Electrical Facilities in Subway Stations)

  • 장수용;김학련
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.844-849
    • /
    • 2006
  • The electric facilities for subway stations require reliable and safe electricity in spite of their load increases rapidly. Nevertheless, Korea Electrical Safety Corporation reports that the accidents of independent electric facilities increased greatly from 4,632 cases in 1998 to 6,024 in 1999 and 6,776 cases in 2000, while the ratio of the accidents related with transformers grew gradually. As it is, it is deemed very important to minimize the spreading effects of the electric system accidents and thereby, enhance reliability of the electric supply as well as its safety. According to the fact that the electric facilities for subway stations are important for the public safety and conveniences, it should be careful to set their capacity instead of simply applying the general capacity standard to them, and thereby, improve their economy as well as prevent their accidents. With such a basic conception in mind, this study is aimed at analyzing the characteristics of the electric load in the subway stations and thereupon, suggesting some guidelines for setting of the electric facility capacity for subway stations in terms of optimal operation and safety.

  • PDF

발전소 터빈제어 밸브시험 계통 모델 개발 (Development of Process Model for Turbine Control Valve Test in a Power Plant)

  • 우주희;최인규;박두용;김종안
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.830-837
    • /
    • 2011
  • A turbine control system which has been operated for years in a nuclear power plant was retrofitted with a newly developed digital control system. After completion of the retrofit, turbine valve tests were performed to ensure the integrity of each valve's control function. The sequence of each valve test is composed of a closing process and a reopening process. To minimize megawatt variation which normally occurs during the test sequence, we employed a kind of compensator algorithm in the new digital control system which also have been used in the old system. There were difficulties finding optimal parameter settings for our new compensator algorithm because the power plant didn't allow us to perform necessary tuning procedures while the turbine is on load operation. Therefore an alternative measure for the compensator tuning which is independent of the turbine actual operation had to be implemented. So, a process model for the test was required to overcome this situation. We analyzed the operation data of the test and implemented the process model by use of input and output variable relations. Also we verified the process model by use of another condition's operating data. The result shows that the output of model is similar to the actual operation data.

Characteristic of Induction Motor Drives Fed by Three Leg and Five Leg Inverters

  • Talib, Md. Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Hasim, Ahmad Shukri Abu
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.806-813
    • /
    • 2013
  • This paper aims to compare the performance of three phase induction motor drives using Five Leg Inverter (FLI) and Three Leg Inverter (TLI) configurations. An Indirect Field Oriented Control (IFOC) method using a TLI is well established and incorporated for high performance speed drives in various industries. The FLI dual motor drive system on the other hand shows good workability in the independent control of two induction motor drives simultaneously. In this experiment, the IFOC method is utilized for both drive systems, and Space Vector Pulse Width Modulation (SVPWM) is used to generate pulses for both inverters. For the FLI, the Double Zero Sequence (DZS) Injection technique is used to generate the modulation signal. The complete experiment setup is done by using a DSpace 1103 controller board. The individual motor performances are analyzed using similar schemes, equipment setups and controller parameter values. The results show similar speed performance response capability between the single motor operation using a TLI system and the two motor operation using a FLI system based on the variable speed range either in forward or reverse operation. They also show similar load rejection abilities. However, the single motor with a TLI has a better power quality aspect such as ripple current and total harmonics distortion (THD).

효과적인 결측치 보완을 통한 다층 퍼셉트론 기반의 전력수요 예측 기법 (A Multilayer Perceptron-Based Electric Load Forecasting Scheme via Effective Recovering Missing Data)

  • 문지훈;박성우;황인준
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제8권2호
    • /
    • pp.67-78
    • /
    • 2019
  • 정확한 전력수요 예측은 스마트 그리드의 효율적인 운영에 있어 매우 중요하다. 최근 IT 기술이 획기적으로 발전되면서, 인공지능 기법을 이용한 빅 데이터 처리를 기반으로 정확한 전력수요를 예측하는 많은 연구가 진행되고 있다. 이러한 예측 모델은 주로 외부 요인과 과거 전력수요를 독립 변수로 사용한다. 하지만, 다양한 내부적 또는 외부적 원인으로 전력수요 데이터의 결측치가 발생하게 되면 정확한 예측 모델을 구성하기가 어렵다. 이에 본 논문에서는 랜덤 포레스트 기반의 결측치 데이터 보완 기법을 제안하고, 보완된 데이터를 기반으로 한 다층 퍼셉트론 기반의 전력수요 예측 모델을 구성한다. 다양한 실험을 통해 제안된 기법의 예측 성능을 입증한다.

비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술 (Hybrid Energy Storage System with Emergency Power Function of Standardization Technology)

  • 홍경진
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.187-192
    • /
    • 2019
  • 수요관리와 정전에 대한 비상전원 기능을 갖춘 하이브리드 전력저장시스템으로 비상발전설비가 필요한 빌딩 및 공장건축 시에 투자비를 최소화하고, 상시 전력비를 절감함으로서 경제성을 확보할 수 있 기술을 개발함으로써 새로운 비즈니스 모델을 제시한다. 평상시에 STS(Static Transfer Switch)를 통해 부하에 계통 전력을 공급하고 PCS는 계통에 병렬로 연계되어 수요관리를 수행한다. EMS는 수요예측을 통한 전력의 효율적 운용을 위해 ESS에 충방전 지령을 PMS(Power Management System)로 하달하고 PMS는 다시 PCS 제어기로 지령을 전달하여 시스템을 운용한다. 정전시에는 STS가 계통으로부터 빠르게 이탈되면서 PCS는 독립 전원이 되어 부하 측에 정전압/정주파수의 전력을 공급할수 있는 구조이다. 따라서 하이브리드 ESS에 대한 실 계통 연계 및 독립 운전 성능 검증을 통한 신뢰성을 확보할수 있고, 저탄소 녹색성장 기술의 효율적 전력망과 연계 운영이 가능하게 함으로써 ESS 연계를 통한 신재생에너지 발전에 의한 불규칙한 전력 품질개선, 피크부하 기여도 제고가 가능하다. 또한 현재 석탄 화력이 담당하고 있는 주파수추종 예비력을 ESS로 대체함에 따라 연료비가 높은 LNG 발전기 가동비용을 절감할 수 있는 기대효과가 있다.

비정상 상황에서 '놀람과 깜짝놀람의 영향(Surprise and Startle Effect)'이 헬리콥터 조종사의 작업부하(Workload)에 미치는 영향에 관한 연구 - 자격증명(자가용 및 사업용) 조종사의 비교 - (A Study on the Helicopter Pilot's Workload Influences by 'Surprise and Startle Effect' in the Abnormal Situation - Comparison by Pilot Certificate (Private and Commercial) -)

  • 이석종;이강석;박원태
    • 한국항공운항학회지
    • /
    • 제30권2호
    • /
    • pp.44-54
    • /
    • 2022
  • An empirical analysis was conducted on the workload of helicopter pilots flying in high-risk flight environments such as ground obstacles and weather effects at low altitudes. To evaluate the workload, an independent sample t-test was performed using the NASA-TLX evaluation method most suitable for the aviation field, and the workload score was calculated by applying the analytical stratification method (AHP) to compare and analyze private and commercial pilots. There is a significant difference in mean between private and commercial pilots and the result of work load was obtained over 70%. This paper studied the 'surprise and startle effect' on the helicopter field for the first time. In the future, it is intended to contribute to the safe operation of helicopters by presenting a method for effective safety management by utilizing it in the field of education and training for helicopter pilots and providing basic data for preventing accidents caused by human error.