A Voltage Regulation System for Independent Load Operation of Stand Alone Self-Excited Induction Generators

  • Kesler, Selami;Doser, Tayyip L.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1869-1883
    • /
    • 2016
  • In recent years, some converter structures and analyzing methods for the voltage regulation of stand-alone self-excited induction generators (SEIGs) have been introduced. However, all of them are concerned with the three-phase voltage control of three-phase SEIGs or the single-phase voltage control of single-phase SEIGs for the operation of these machines under balanced load conditions. In this paper, each phase voltage is controlled separately through separated converters, which consist of a full-bridge diode rectifier and one-IGBT. For this purpose, the principle of the electronic load controllers supported by fuzzy logic is employed in the two-different proposed converter structures. While changing single phase consumer loads that are independent from each other, the output voltages of the generator are controlled independently by three-number of separated electronic load controllers (SELCs) in two different mode operations. The aim is to obtain a rated power from the SEIG via the switching of the dump loads to be the complement of consumer load variations. The transient and steady state behaviors of the whole system are investigated by simulation studies from the point of getting the design parameters, and experiments are carried out for validation of the results. The results illustrate that the proposed SELC system is capable of coping with independent consumer load variations to keep output voltage at a desired value for each phase. It is also available for unbalanced consumer load conditions. In addition, it is concluded that the proposed converter without a filter capacitor has less harmonics on the currents.

A Study on the Modeling and Operation Algorithm of Independent Power System for Carbon Free (Carbon Free를 위한 도서지역용 독립전원계통의 모델링 및 운용알고리즘에 관한 연구)

  • Wang, Jong-Yong;Kim, Byung-Ki;Park, Jea-Bum;Kim, Byung-Mok;Kim, Eung-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.760-768
    • /
    • 2016
  • Recently, as one of the policies for carbon free operation method of independent power system replacing diesel generator with renewable energy such as wind power and photovoltaic(PV) system has been presented. Therefore, this paper proposes an operation algorithm and modeling of independent power system by considering CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage, LC(load control) ESS for demand and supply balancing and SVC(static var compensator) for reactive power compensation. From the simulation results based on the various operation scenario, it is confirmed that proposed operation algorithm and modeling may contribute stable operation and carbon free in independent power system.

A Study on the Independent Operation and Connected Operation of Microgrid (마이크로그리드의 독립운영 및 연계운영에 관한 연구)

  • Oh, Hyun-Ju;Park, Sung-Jun;Park, Seong-Mi;Kim, Chun-Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_3
    • /
    • pp.1199-1206
    • /
    • 2022
  • Fossil fuels are one of the various energy sources used by humans, and industrial development has been achieved by relying on fossil fuels for a long time in the past. In order to respond to the depletion of fossil fuels and climate change, the world is trying to build an eco-friendly energy ecosystem. Research on efficiency improvement using renewable energy and ESS in various ways for energy conversion is being promoted. In this paper, a microgrid for industrial complexes was designed, constructed, and demonstrated. It was operated in two modes: an independent mode that each plant generates and uses independently and a connected operation mode that allows energy sharing between factories. In the case of independent mode, PV and PCS were intermittently stopped and restarted according to the status change of SoC section of each site. But, in the case of the connected operation mode, stable power supply was confirmed through power transaction through the operation of the entire SoC. This paper presented and verified an algorithm to stably supply power to industrial complexes consisting of various consumers with different load characteristics.

Economic Profit Analysis for Centralized Operation of Economic Load Dispatch Problem (경제급전문제의 통합운영에 관한 경제적 이득 분석)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.181-188
    • /
    • 2016
  • This paper demonstrates that centralized economic load dispatch optimization is much more economical than independent optimization carried out by individual power generating companies. The algorithm applied here optimizes by balancing the generation power at the valve-point, then readjusting generation power by comparing incremental operating cost incurred by marginal increase in the generation power and decremental operating cost likewise incurred by marginal decrease in the generation power. Upon comparing 3 individual optimization cases of 10, 13, and 40 generators respectively with centralized optimization of 63 generators, centralized operation for economic load dispatch optimization has proven to maximize economic benefits by markedly reducing operation costs of individual optimization.

A Takagi-Sugeno fuzzy power-distribution method for a prototypical advanced reactor considering pump degradation

  • Yuan, Yue;Coble, Jamie
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.905-913
    • /
    • 2017
  • Advanced reactor designs often feature longer operating cycles between refueling and new concepts of operation beyond traditional baseload electricity production. Owing to this increased complexity, traditional proportional-integral control may not be sufficient across all potential operating regimes. The prototypical advanced reactor (PAR) design features two independent reactor modules, each connected to a single dedicated steam generator that feeds a common balance of plant for electricity generation and process heat applications. In the current research, the PAR is expected to operate in a load-following manner to produce electricity to meet grid demand over a 24-hour period. Over the operational lifetime of the PAR system, primary and intermediate sodium pumps are expected to degrade in performance. The independent operation of the two reactor modules in the PAR may allow the system to continue operating under degraded pump performance by shifting the power production between reactor modules in order to meet overall load demands. This paper proposes a Takagi-Sugeno (T-S) fuzzy logic-based power distribution system. Two T-S fuzzy power distribution controllers have been designed and tested. Simulation shows that the devised T-S fuzzy controllers provide improved performance over traditional controls during daily load-following operation under different levels of pump degradation.

Operation-sequence-based Approach for Designing a U-shaped Independent-Cell System with Machine Requirement Incorporated (설비능력과 작업순서를 고려한 U-라인상에서의 셀 시스템 설계)

  • 박연기;성창섭;정병호
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.26 no.1
    • /
    • pp.71-85
    • /
    • 2001
  • This paper considers a cost model for a U-shaped manufacturing cell formation which incorporates a required number of machines and various material flows together under multi-part multi-cell environment. The model is required to satisfy both the specified operation sequence of each part and the total part demand volume, which are considered to derive material handling cost in U-shaped flow line cells. In the model several cost-incurring factors including set-up for batch change-over, processing time for operations of each part, and machine failures are also considered in association with processing load and capacity of each cell. Moreover, a heuristic for a good machine layout in each cell is newly proposed based on the material handling cost of each alternative sequence layout. These all are put together to present an efficient heuristic for the U-shaped independent-cell formation problem, numerical problems are solved to illustrate the algorithm.

  • PDF

Bid-based Direct Load Control Framework Under Electricity Markets (전력시장 환경하에 입찰기반의 직접부하제어 운영방안)

  • Lee, Ho-Chul;Song, Sung-Hwan;Yoon, Yong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.455-461
    • /
    • 2009
  • This paper proposes Direct Load Control(DLC) operation scheme using a bidding system and the methodology to value proper quantity decided by the DLC program, which is a kind of resources for stabilization of electricity market price during peak times by managing consumer electricity demand. Since DLC program in Korea is based on the contract with the customers participating in this program, it is difficult to anticipate voluntary participation. That is, incentive for participants in DLC program is insufficient. To cope with this point, it is necessary to develop a new market mechanism and market compatible operation scheme for DLC programs. DLC market mechanism is deemed to be equipped with iterative bidding system, independent operation from energy market, and interactive with bidding information on energy market. With this market mechanism, it is important to find the optimal operation point of DLC allowing for the factors of stabilizing the electricity market price and compensating DLC implementation. This paper focuses on the mathematical approaches for the bid-based DLC operation scheme and examines several scenarios for the following technical justifications: 1) stabilization of electricity market price during peak times, 2) elasticity of demand.

Micro-Grids Reliability Enhancement Under Different Penetration Levels of Hybrid DG Units

  • Essam, M.;Atwa, Y.M.;El-Saadany, Ehab F.;Conti, Stefania;Rizzo, Santi Agatino
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1407-1418
    • /
    • 2018
  • Novel mechanism of customized adequacy formulation is proposed in order to enhance micro grids system reliability. The mechanism accounts for 2-levles of load curtailment, and is mainly based on probabilistic load profile and hybrid Distributed Generation (DG) units modeling. The two load curtailments are needed in order to ensure adequate technical constraints at steady state condition during islanding mode of operation. The effectiveness of the proposed formulation has been verified using system independent analytical expressions for the evaluation of both reliability and Expected Energy Not Served (EENS) indices. The evaluation has examined the impact of different penetration levels of Hybrid DG Units in case study islands. Results show the enhancement of the overall distribution system reliability and the recommended conditions for successful islanding mode of operation.

Technology Development for Stabilization of PV Independent System (태양광발전시스템 독립계통 안정화 기술개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.5
    • /
    • pp.181-186
    • /
    • 2019
  • In order to reduce the fossil fuels consumed in conventional commercial independent diesel generators in the same environment as the island area, it is necessary to develop a photovoltaic system that will bear more than 40% of the independent system capacity. For this development, it is necessary to develop a high-capacity inverter that can improve the stability of the independent system installed in the island area and supply high-quality power to the load. In addition, the EMS power generation control system for the independent grid photovoltaic power generation system is a parallel operation power control system of the diesel generator connected with the solar power generation system. It controls the output of the diesel generator according to the load ratio and the solar power generation, A stable supply system is needed. This independent grid photovoltaic generation system can increase the solar power supply to the independent system area and increase the power stability of the independent system and further reduce the use of fossil fuel due to the ineffective power control of the independent system. It is expected that the economy will be secured early.

Operation Scheduling of Multi-Cogeneration System with Various Thermal Load (다양한 종류의 열부하를 가진 다기열병합발전시스템의 최적운용계획 수립)

  • Jung, Ji-Hoon;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1273-1275
    • /
    • 1999
  • This paper describes the optimal operation scheduling on cogeneration systems which have thermal loads of different pressure each other. The cogeneration systems has two units and operate connecting with various auxiliary devices as heat storage tanks, independent generators and auxiliary boilers. The optimal modeling and scheduling technique proposed in this paper will be applied to industrial cogeneration systems.

  • PDF