• Title/Summary/Keyword: Incremental heat rate

Search Result 6, Processing Time 0.022 seconds

A Study on the Resetting of Incremental Heat Rate Curve of Combined Cycle Unit by Combination (복합발전기 조합별 증분비 곡선 재설정에 관한 연구)

  • Hong, Sang-Beom;Choi, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.8-12
    • /
    • 2019
  • Combined Cycle Unit(CC) generates the primary power from the Gas Turbine(GT) and supplies the remaining heat of the GT to the Steam Turbine(ST) to generate the secondary power from the ST. It plays a major role in terms of energy efficiency and Load Frequency Control(LFC). Incremental Heat Rate(IHR) curves of economic dispatch(ED) of CC is applied differently by GT/ST combination. But It is practically difficult because of performance test by all combinations. This paper suggests a reasonable method for estimating IHR curves for partial combinations(1:1~(N-1):1) using IHR curves when operating with GT alone(1:0) and with all(N:1) combinations of CC.

Theoretical Performance Analysis of a Modified Rectangular Fin (변형된 사각 핀의 이론적 성능해석)

  • 강형석;김영준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.683-690
    • /
    • 2004
  • A modified rectangular fin is analyzed by two-dimensional analytic method and finite difference method. Relative error of heat loss from the modified rectangular fin between analytic method and finite difference method is presented. Comparisons of fin effectiveness and heat loss between a modified rectangular fin and a plane rectangular fin are made as a function of the non-dimensional fin length and wing height for different positions of wings by using analytic method. The ratio of the incremental rate of heat loss to that of the area of a modified rectangular fin is shown as a function of the wing height. One of the results shows that performance of a modified fin is more improved as the wing approaches the fin root.

Heat Evaluation System in Concrete Considering Evaporation Heat (기화열을 고려한 콘크리트의 온도평가시스템 개발)

  • Lee, Tae-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.12
    • /
    • pp.604-611
    • /
    • 2015
  • When the moisture in concrete member evaporates by high temperature, the evaporation heat which absorbs surrounding temperature occurs. The incremental rate of the internal temperature in concrete is reduced due to the evaporation heat in spite of continuously increasing external temperature. Therefore, this paper has proposed the evaluation algorithm for predicting the internal temperature of concrete members considering the evaporation heat under the high temperature. Finite element method is employed to facilitate thermal analysis for any position of member. To demonstrate the validity of this numerical procedure, the prediction by the proposed algorithm is compared with the test results of other researchers. The proposed algorithm shows a good agreement with the experimental results including the phenomenon that temperature is lost by the evaporation heat.

Analysis of a Modified Plate Fin for Enhanced Performance of a Plate Fin Heat Exchanger (평판 핀 열교환기의 성능 향상을 위한 변형된 평판 핀에 대한 해석)

  • 김윤하;강형석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.84-91
    • /
    • 2001
  • Comparison between performance of a plate fin and that of a modified plate fin is investigated as a function of the position, the non-dimensional width and height of wings as well as the non-dimensional fin length using a two-dimensional separation of variables method. The ratio of the incremental rate of heat loss to that of the area of a modified plate fin is also presented as a function of the height of wings. The modified plate fin is made by attaching the wings to upper and lower sides of a plate fin. One of the results shows that performance of a modified plate fin is more improved as the wings approach left (higher) thermal reservoir.

  • PDF

[ $Papridry^{TM}$ ], A New Technique for Drying of Paper and Board

  • Pikulik, I.I.
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06a
    • /
    • pp.19-29
    • /
    • 2006
  • Drying is the least developed of all unit operations of paper and board manufacture. While groundbreaking developments were Introduced during the several past decades in forming, pressing and calendering, no radical changes occurred in drying. The cylinder-drying technology is now more than 200 years old and, while it was subject to many incremental improvements, many of its inherent problems persist. We believe that conventional drying is now approaching the end of its life and the industry is ready for a major breakthrough in drying. Indeed several innovative technologies already exist at various stages of development or commercialization. In general, the novel drying technologies are striving to increase the drying rate, improve the product quality and boost the energy efficiency of drying. A novel, drying method, $Papridry^{TM}$, which combines conductive and convective heat transfer to obtain very high drying rates, is at an advanced stage of development at Paprican. The results obtained when drying printing paper ana board on a self-standing pilot $Papridry^{TM}$ machine and on the pilot paper machine equipped with a tandem of two $Papridry^{TM}$ units demonstrate both, the high drying rate and improved product quality achieved by using this drying method. A mathematical model of this operation has been developed and the software compiled with this model was used to calculate the effect of installing a $Papridry^{TM}$ unit into an existing dryer section. The model also allows to calculate the z-direction distribution of moisture and temperature at various points of the dryer section.

  • PDF

An Economic Analysis of the Effluent Heat Supply from Thermal Power Plant to the Farm Facility House (화력발전소 온배수열 활용 시설하우스 열공급 모형 경제성분석 연구)

  • Um, Byung Hwan;Ahn, Cha Su
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.6-13
    • /
    • 2018
  • Utilizing the heat of cooling water discharge of coal-fired power plant, pipeline investment costs for businesses that supply heat to agricultural facilities near power plants increase in proportion to installation distance. On one hand, the distance from the power plant is a factor that brings difficulties to secure economic efficiency. On the other, if the installation distance is short, there is a problem of securing the heating demands, facility houses, which causes economical efficiency to suffer. In this study, the economic efficiency of 1km length of standard heat pipeline was evaluated. The sensitivity of the heat pipe to the new length variation was analyzed at the level of government subsidy, amount of heating demand and the incremental rate of pipeline with additional government subsidy. As a result of the analysis, it was estimated that NPV 131 million won and IRR 15.73%. The sensitivity analysis showed that NPV was negative when the length of heat pipe facility exceeded 2.6 km. If the government supports 50% of the initial investment, the efficiency is secured within the estimated length of 5.3 km, and if it supports 80%, the length increases within 11.4 km. If the heat demand is reduced to less than 62% at the new length of the standard heat pipe, it is expected economic efficiency is not obtained. If the ratio of government subsidies to initial investment increases, the elasticity of the new bloc will increase, and the fixed investment, which is the cost of capital investment for one unit of heating demand, will decrease. This would result in a reduction in the cost of production per unit, and it would be possible to supply heat at a cheaper price level to the facility farming. Government subsidies will result in the increased economic availability of hot plumbing facilities and additional efficiencies due to increased demand. The greater government subsidies to initial investment, the less farms cost due to the decrease in the price per unit. The results of the study are significant in terms of the economic evaluation of the effectiveness of the government subsidy for the thermal power plant heat utilization project. The implication can be applied to any related pilot to come.