2차 공기 주입각도에 따른 소각로 내부의 재순환 영역 변화 (The change of recirculation zone with the inlet angle of secondary air in an incinerator)

  • 김성준;박민주;전봉준
    • 산업기술연구
    • /
    • 제20권B호
    • /
    • pp.55-62
    • /
    • 2000
  • The purpose of this research is to find out how the inlet angle of secondary air affects the formation of recirculation zone inside a small incinerator. A commercial code, PHOENICS, is used to simulate the flow field of an incinerator. The computational grid system is constructed by Multi-Block technique. Numerical experiments are done with the five different angles of secondary air inlet. The formation of recirculation zone is evaluated by checking velocity fields. The computational results show that recirculation zone is clearly formed from 60 degree of inlet angle and the zone of recirculation is widen as angle of recirculation is increased to $75^{\circ}$.

  • PDF

선박용 소각로 이젝터의 배출온도 변화에 따른 유동과 배기특성 (The Stream and Exhaust Gas Characteristics for Variation of Exhaust Gas Temperature of Marine Incinerator Ejector)

  • 김태한
    • 한국해양공학회지
    • /
    • 제14권2호
    • /
    • pp.60-64
    • /
    • 2000
  • An experimental study was performed to investigate the optimal ejector and operating condition of vessel incinerator. Exhaust gas temperature and secondary air which makes vacuum pressure at ejector throat regions were considered as an important factor. According to the measurement of pressure temperature and nitrogen oxides between non combustion and combustion we found the stream and exhaust gas characteristics of incinerator. This results can give us the exhaust gas temperature control system air pollutant reduction method and the optimum ejector design.

  • PDF

소각로의 연소 공기 유동 해석 (Analysis of Combustion Air Flow in Incinerator)

  • 이동혁
    • Design & Manufacturing
    • /
    • 제16권2호
    • /
    • pp.26-32
    • /
    • 2022
  • It is known that the fluidized bed incinerator, which is the subject of analysis, shows excellent performance in heat and mass transfer due to excellent mixing and contact performance between fluidized sand and fuel, and also shows relatively good combustion characteristics thanks to good mixing and long residence time for low-grade fuels. have. In this study, air flow analysis is performed to understand the characteristics of co-firing of sludge, waste oil and solid waste in the fluidized bed incinerator, flow characteristics of flue gas, and discharge characteristics of pollutants.The fluidized bed incinerator subject to analysis is a facility that incinerates factory waste and general household waste together with sludge, with a processing capacity of 32 tons/day. to be. In addition, the operation method was designed for continuous operation for 24 hours. As a result, it can be seen that the lower combustion air and the introduced secondary air are changed to a strong turbulence and swirl flow form and exit through the outlet while rotating inside the freeboard layer. The homogeneous one-way flow form before reaching the secondary air nozzle has very high diffusivity with the high-speed jet flow of the nozzle.

폐기물 소각시설 배가스에서의 수은 배출특성 (The Characteristics of Mercury Emission from Municipal Solid Waste (MSW) Incinerator Stack)

  • 이한국
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.378-387
    • /
    • 2004
  • This study was carried to investigate the emission characteristics of mercury from domestic and industrial MSW (municipal solid waste) incinerator stacks. The mercury concentration levels of flue gas from 32 MSW incinerators stacks selected were above the criteria level ($5{\mu}g/S\;m^3$). MSWI facilities exceeding the criteria levels in Korea are due to the poor units comparison of combustion chamber(CC)-cyclone(CY)-stack. So, the mercury from MSW incinerators stack were suspected to contaminate the natural system unless the MSW incinerators were properly controlled. Mean-while, the relationship between mercury concentration and temperature of flue gas in MSW incinerator stacks were examined at two temperature ranges (Group A : $29.85{\sim}327.63^{\circ}C$, Group B : $446.9{\sim}848.15^{\circ}C$). The mercury concentration in flue gas with high temperature range was higher than that of flue gas with low temperature rage. This mean that the temperature of flue gas plays an important role in mercury control in MSW incinerator. The emission characteristics oi mercury was also evaluated by using the correlation matrix between the mercury and NOx, $PM_{10}$, moisture (MO.) at both low temperature and high temperature flue gas ranges. The mercury concentration was mainly affected by NOx, $PM_{10}$. moisture (MO.) at low temperature range, while the mercury concentration at high temperature flue gas was mainly affected by NOx, moisture (MO.). From these results, it was suggested that the temperature of cooling system and the air pollution control device should be properly regulated in order to control mercury of flue gas in MSWI incinerator.

쓰레기 소각재 사용 콘크리트의 품질특성에 대한 실험적 연구 (An Experimental Study on the Quality of Concrete with Municipal Solid Waste Incineration Ash)

  • 김재우;최재진;문대중
    • 한국건설순환자원학회논문집
    • /
    • 제2권4호
    • /
    • pp.335-344
    • /
    • 2014
  • 쓰레기 소각재(소각재)를 콘크리트용 재료로 재활용하기 위하여 소각재의 품질특성에 대하여 분석하였으며, 소각재를 사용한 콘크리트의 유동특성 및 강도특성에 대하여 검토하였다. 소각재의 화학성분은 CaO 성분이 50%이상을 차지하고 있었으며, 소각재의 누적입도분포 50%의 평균입경은 $25{\mu}m$ 정도를 나타내었다. 소각재 IA1의 입자형상은 미세입자가 뭉쳐져 구형상을 나타내고 있으며, 소각재 IA2의 입자형상은 미세입자가 판상 형상으로 겹쳐져 있는 구조로 제조공정에 따라 다르게 나타났다. 소각재를 사용하므로써 콘크리트의 품질특성에도 크게 영향을 미쳤으며, 소각재 IA2를 사용한 경우 슬럼프가 증가하고 고성능감 수제 사용량이 감소하였으나, 압축강도 발현은 저하하였다. 소각재 IA2와 규조분말을 병용하여 혼합하므로써 목표슬럼프를 얻기 위한 고성능감수제의 사용량은 증가하였으나, 재령 28일 압축강도는 향상되는 효과가 있었다. 또한, 압축강도와 인장강도와의 비는 CEB-FIP 코드의 85%~105% 범위내에 있었다.

Risk perceptions of a population living near a municipal waste incinerator and associated factors with the prevalence of environmental disease

  • Dong Hyun Kim;Chae Kwan Lee;Jeong Ho Kim;Byung Chul Son;Chunhui Suh;Kunhyung Kim;Byeong Jin Ye
    • Annals of Occupational and Environmental Medicine
    • /
    • 제34권
    • /
    • pp.38.1-38.9
    • /
    • 2022
  • Background: This study investigated the risk perceptions, prevalence of environmental diseases (EDs) and associated factors with the prevalence of environmental disease among the population living near an incinerator Methods: Study area were divided into 3 local areas near the incinerator by distance (A, B, C) and control area (D) by distance and geographic isolation. A Questionnaire was conducted with 1,380 in local residents (A, B, C) and 390 in control area (D), gathered information of demographic characteristics, lifestyle, perception of damage by incinerators, experience of EDs (atopic dermatitis, allergic rhinitis, asthma) diagnosed by physician. Analysis of variance, χ2 test, and Kruskal Wallis test was applied to determine the difference by area. Logistic regression analysis was performed to identify factors associated with the prevalence of allergic rhinitis. Results: Residents residing closer to the incinerator had negative perception in most items in questionnaire compared with control. The prevalence of allergic rhinitis was higher as they lived nearby the incinerator (p = 0.008). The associated factors with the prevalence of allergic rhinitis were carpet (odds ratio [OR]: 1.79, p = 0.001), residential area (marginally significant), duration of residence (OR: 1.09, p < 0.001). The perception of environmental pollution around the residential area was inversely associated with the prevalence of allergic rhinitis: perceived as very dissatisfied (OR: 4.21, p = 0.02) compared with very satisfied. Conclusions: As closer to the incinerator, the risk perception tend to negative and prevalence of EDs were increased. Carpet, residential area, duration of residence and perception of environmental air pollution around the residential area were associated with prevalence of allergic rhinitis. These results may be useful for the communication with residents to discuss the environmental problems caused by the incinerator.

국내 일부 소각장 근로자와 주변지역주민들의 PCDDs/Fs 노출과 건강 영향 평가 (Exposure Assessment of PCDD/Fs and Monitoring of Health Effects on Workers and Resident near the Waste Incinerators in Korea)

  • 홍윤철;이관희;권호장;장재연;임종한
    • Journal of Preventive Medicine and Public Health
    • /
    • 제36권4호
    • /
    • pp.314-322
    • /
    • 2003
  • Objectives : In this study, the exposure status of the hazardous substances from incinerators, such as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), were studied , and the relationship between the exposure of these hazardous substances and their heath effects on the workers and residents near municipal solid waste (MSW) incinerators and an industrial incinerator investigated. Methods : Between July 2001 and Jure 2002, 13 workers at two MSW incinerators, 16 residents from the area around the two MSW incinerators, 6 residents from the control area, and further 10 residents near an industrial incinerator, estimated to emit higher levels of hazardous substances, were interviewed. Information, including sociodemographic information, personal habits, and work history, detailed gynecologic and other medical history were collected through interviews. Blood samples were also collected from 45 subjects, and analyzed for PCDD/DFs, by high resolution gas chromatography -high resolution mass spectrometry, using the US EPA 1613 method. In addition to the questionnaire survey, urinary concentrations of 8-hydroxydeoxyguanosine (8-OH-dG) and malondialdehyde (MDA) were measured as oxidative injury biomarkers. The urinary concentrations of 8-OH-dG were determined by in vitro ELISA, and the MDA by HPLC, using u adduct with thiobarbituric acid. Results : The PCDD/DFs concentrations in the residents near the industrial incinerator were higher than those in the controls, workers and residents near the MSW incinerators. The average TEQ (Toxic Equivalencies) concentrations of the PCDD/DFs in residents near the industrial incinerator were 53.4pg I-TEQs/g lipid. The estimated daily intakes were within the tolerable daily intake range (1-4 pg I-TEQ/Kg bw/day) suggested by WHO (1997) in only 30% to the people near the industrial incinerator. Animal studies have already shown that even a low body border of PCDD/DFs, such as 10 ng TEQ/kg bw, can cause oxidative damage in laboratory animals. Our study also showed that the same body burden of PCDD/DFs can cause oxidative damage to humans. Conclusions : The exposures to PCDD/DFs and the oxidative stress of residents near the industrial incinerator, were higher than those in the controls, workers and residents near the MSW incinerators. Proper protection strategies against these hazardous chemicals are needed. Because a lower body burden of PCDD/Fs, such as 10ng TEQ/kg bw, can cause oxidative damage, the tolerable daily intake range should be restrictedly limited to 1pg I-TEQ/kg bw/day.