• Title/Summary/Keyword: IncP

Search Result 1,380, Processing Time 0.029 seconds

Optical Sensitivity of TL Glow Peaks Separated Using Computerized Glow Curve Deconvolution for RTL Quartz

  • Kim, Myung-Jin;Kim, Ki-Bum;Hong, Duk-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.114-119
    • /
    • 2018
  • Background: The retrospective dosimetry using RTL quartz can be improved by information for an optical sensitivity of sample connected with the equivalent dose determination. Materials and Methods: The quartz sample from a volcanic rock of Japan was used. After correcting the thermal quenching effect, RTL peaks of quartz were separated by the CGCD method cooperated with the general order kinetics. The number of overlapped glow peaks were ascertained by the $T_m-T_{stop}$ method. The optical sensitivity was examined by comparing the change of intensity on RTL glow peaks measured after exposure to light from a solar simulator with various illumination times. Results and Discussion: Seven glow peaks appeared to be overlapped on the RTL glow curve. The general order kinetics model was appropriate to separate glow peaks. After exposure to light from a solar simulator from a few minutes to 416 hr, the signals for peaks P4 and P5 decayed following the form of $f(t)=a_1e^{-{\lambda}1t}$, while the signals for peaks P6 and P7 decayed by the form of $f(t) = a_1e^{-{\lambda}1t}+a_2e^{-{\lambda}2t}+a_3e^{-{\lambda}3t}$. Conclusion: For dosimetric peaks, the times taken to reduce the RTL signal to half of its initial value were 70 sec for the peak P4, 54 s for the peak P5, 9,840 sec for the peak P6 and 26,580 sec for the peak P7, respectively. We conclude that the optical sensitivity of peaks P4, and P5 gives much higher than that of peaks P6 and P7.

The Effects of Crosslinking Agent and pH Controlling Agent on Adhesive Properties of Water Soluble Acrylic PSA (가교제 및 pH 조절제가 수용성 아크릴 점착제의 점착 물성에 미치는 효과)

  • Seo, In-Seon;Park, Myung Chul;Lee, Myung Cheon
    • Journal of Adhesion and Interface
    • /
    • v.4 no.3
    • /
    • pp.9-13
    • /
    • 2003
  • In this paper, the effects of crosslinking agent and pH controlling agent on adhesive properties and water solubility of water soluble acrylic pressure sensitive adhesives were studied by adding the crosslinking agents or pH controlling agents after the polymerization. the tack, cohesive strength, and peel strength were measured to evaluate adhesive properties. the turbidity was also measured to evaluate water solubility of pressure sensitive adhesives. When crosslinking agent was added less than 0.2 wt%, tack increased and cohesive strength and peel strength decreased with increasing concentration. When crossinking agent was added more than 0.2 wt%, the results were opposited. When pH controlling agent was added, tack and water solubility decreased and peel strength and cohesive strength increased with increasing concentration. the influence of pH controlling agents on adhesive properties and water solubility of pressure sensitive adhesive increased in the order of lithium hydroxide, potassium hydroxide and sodium hydroxide.

  • PDF

Pupil Data Measurement and Social Emotion Inference Technology by using Smart Glasses (스마트 글래스를 활용한 동공 데이터 수집과 사회감성 추정 기술)

  • Lee, Dong Won;Mun, Sungchul;Park, Sangin;Kim, Hwan-jin;Whang, Mincheol
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2019.11a
    • /
    • pp.1-4
    • /
    • 2019
  • 본 연구에서는 적외선 카메라 기반의 비접촉식 측정 방법을 이용하여 동공 반응 데이터를 수집하여 공감의 사회감성을 객관적이고 정량적으로 추정하는데 그 목적이 있다. 실험에는 10명(남 6명, 여 4명, M ± SD = 24.17 ± 2.16세)의 피험자가 참여하였다. 30초의 참조 데이터 측정 후, 공감 유무에 따라 과제는 얼굴 표정 모방 과제와 얼굴 표정 자발적 표현 과제로 구분되어 두 사람은 표정으로 상호작용하였고, 2번씩 반복 진행하며 적외선 카메라를 통해 동공을 촬영하였다. 이진화 및 원형 윤곽선 검출법의 영상처리를 활용하여 동공 데이터를 수집하였고, 이동 평균 기법을 활용해 눈깜빡임 노이즈를 제거하고 동공 크기 개인차로 데이터 표준화를 진행하였다. 공감 유무에 따른 동공 크기 데이터는 정규성 검증 및 독립표본 t검정을 통해 통계적 유의성을 확인하였다. 분석결과, 공감하는 경우(M ± SD = 0.508 ± 1.278)와 공감하지 않은 경우(M ± SD = 1.681 ± 0.968) 동공 크기가 통계적으로 유의미한 차이를 보였다(t(18) = -2.313, p = 0.033). 판별분석을 통해 동공 크기에 따른 공감의 유무를 추정하는 규칙을 정의하였다. 본 연구에서 제안한 동공 크기 데이터를 이용한 공감의 사회감성 추정 기술은 비접촉식 카메라 기반의 기술로 스마트 글래스와 접목되어 다양한 분야에 활용도가 높을 것으로 기대된다.

  • PDF

A Study on the Effect of Mandibular Orthopedic Repositioning Appliance (MORA) on Back Muscle Strength (Mandibular orthopedic repositioning appliance(MORA)가 배근력에 미치는 영향에 관한 연구)

  • 현기용;이승우
    • Journal of Oral Medicine and Pain
    • /
    • v.10 no.1
    • /
    • pp.113-124
    • /
    • 1985
  • In order to observe the effect of mandibular orthopedic repositioning appliance (MORA) on body strength, the author measured back muscle strength with Digital Back Muscle DYNAMOMETER (TAKEI KIKI KOGYO Co., Tokyo, Japan) before MORA, 15 days after and 30 days after MORA in 12 men and then analysed them statistically. The subjects were weight-lifting athletes of Seoul Athletic High School without dysfunction of masticatory system. MORA was fabricated at 1.0-1.5rnm isotonically closed position (Myocentric Occlusion Position) from mandibular rest position (Myocentric Rest Position) using Myo-monitor (MyoTronics Research Inc., Seattle, Washington, USA) and-SVT C-II (Tokyo Shizaisha Inc., Tokyo, Japan). The results were as follows : 1. The mean of back muscle strength before MORA was 150 kg, that of 15 days after MORA was 165 kg (4.43% increase than before), and that of 30 days was 175 kg (10.76% increase than before). 2. There was a significant difference among back muscle strength before MORA, 15 days after and 30 days after MORA (P<0.01: repeated measures one-way ANOVA). 3. According to the result of determining mandibular position for MORA fabrication, mandibular rest position after relaxation with Myo-monitor was 3.2mm lower, 1.0mm posterior, and 0.5 mm left from centric occlusion. And the mean of the amount of lateral deviation was 0.7 mm.

  • PDF

Expression of Yeast Cyclophilin A (Cpr1) Provides Improved Stress Tolerance in Escherichia coli

  • Kim, Il-Sup;Shin, Sun-Young;Kim, Young-Saeng;Kim, Hyun-Young;Lee, Dong-Hee;Park, Kyung-Moc;Jin, Ingn-Yol;Yoon, Ho-Sung
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.6
    • /
    • pp.974-977
    • /
    • 2010
  • Cyclophilins contain the conserved activity of cis-trans peptidyl-prolyl isomerase, which is implicated in protein folding, and function as molecular chaperones. When the yeast cyclophilin A gene (cpr1) was subcloned into the prokaryotic expression vector pKM260, it was found that the expression of Cpr1 drastically increased the cell viability of E. coli BL21 when under abiotic stress conditions, as in the presence of cadmium, copper, hydrogen peroxide, heat, and SDS. Therefore, this study illustrates the importance of Cpr1 as a molecular chaperone that can improve the cellular stress responses when E. coli cells are exposed to adverse conditions, while also demonstrating its potential to increase the stability of E. coli strains utilized for the production of recombinant proteins.

Purification and Biochemical Characterization of Recombinant Alanine Dehydrogenase fvom Thermus caldophilux GK24

  • Bae, Jung-Don;Cho, Youn-Jeung;Kim, Doo-Il;Lee, Dae-Sil;Shin, Hyun-Jae
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.4
    • /
    • pp.628-631
    • /
    • 2003
  • The recombinant alanine dehydrogenase (ADH) from E. coli containing Thermus caldophilus ADH was purified to homogeneity from a cell-free extract. The enzyme was purified 38-fold with a yield of 68% from the starting cell-free extract. The purified enzyme gave a single band in polyacrylamide gel electrophoresis, and its molecular weight was estimated to be 45 kDa. The pH optimum was 8.0 for reductive amination of pyruvate and 12.0 for oxidative deamination of L-alanine. The enzyme was stable up to $70^{\circ}C$. The activity of the enzyme was inhibited by 1 mM $Zn^{2+}$, 20% hexane, and 20% $CHCl_3$. However, 10 mM $Mg^{2+}$ and 40% propanol had no effect on the enzyme activity. The Michaelis constants ($K_m$) for the substrates were $50\;\mu\textrm{M}$ for NADH, 0.2 mM for pyruvate, 39.4 mM for $NH_4+$, 2.6 mM for L-alanine, and 1.8 mM for $NAD^+$.

Development and Characterization of Ru CMP Slurry (Ru CMP Slurry의 개발 및 특성평가)

  • Kim, In-Kwon;Kwon, Tae-Young;Park, Jin-Goo;Park, Hyung-Soon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.57-58
    • /
    • 2006
  • In MIM (metal insulator metal) capacitor, Ru (ruthenium) has been suggested as new bottom electrode due to its excellent electrical performance, a low leakage of current and compatibility to the high dielectric constant materials. In this case of Ru bottom electrode, CMP (chemical mechanical planarization) process was needed m order to planarize and isolate the bottom electrode. In this study, the effect of chemical A on polishing and etching behavior was investigated as functions of chemical A concentration, abrasive particle and pressure. Chemical A was used as oxidant and etchant. The thickness of passivation layer on the treated Ru surface increased with the increase of chemical A concentration. The etch rate and removal rate of Ru were increased by the addition of chemical A. The removal rate was highest m slurry of pH 9 with the addition of 0.1 M chemical A and 2 wt% alumina at 4 psi. The maximum removal rate is about 80 nm/min.

  • PDF

Economic Feasibility Study for Peak Load Control (최대부하제어(最大負荷制御)의 경제적(經濟的) 타당성(妥當性) 검토(檢討))

  • Yu, Sung-Chul;Yoon, Kap-Koo;Cho, Soon-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.19-22
    • /
    • 1993
  • Demand side management (DSM) is the planning and implementation of those utility designed to influence customer use of electricity in ways that will produce desired changes in the utility's load shape. It is conspicuous that the peak load control of DSM is efficiently adopted. In this paper, the package type air conditioner(A/C) mounted radio controlled switch. During the summer of 1990 KEPCO conducted tests in Seoul areas to determine the economic feasibility of interrupting A/C units for short periods of time during peak load periods. These tests were performed between July 30 and September 20 and were limited to the hours of between 1 and 6 p.m. These tests indicated that each A/C contributes approximately 4.5kW to the system peak and can be switched off 10 minutes out of each 1/2 hour without causing the customer any discomfort. Switching each A/C off for 10 minutes out of each 1/2 hour results in a peak load demand reduction of one kW per unit.

  • PDF

Post-Processing of Speech Recognition Using Phonological Variables and Improved Edit-distance (발음 변이와 개선된 편집 거리를 이용한 음성 인식 후처리)

  • Kim, Yejin;Park, Youngmin;Kang, Sangwoo;Jung, Sangkeon;Lee, Cheongjae;Seo, Jungyun
    • Annual Conference on Human and Language Technology
    • /
    • 2014.10a
    • /
    • pp.9-12
    • /
    • 2014
  • 본 논문에서는 오인식된 고유명사의 후처리 방법을 제안한다. 최근 음성 인식 후처리를 위해 통계적 방법을 이용하는 연구가 활발히 진행되어 왔다. 하지만 고유명사의 음성 인식 후처리는 대용량의 데이터 수집에 많은 비용이 필요하므로 통계적 방법을 효과적으로 적용하기 어렵다. 따라서 본 논문에서는 발음 변이 현상을 고려하여 편집 거리 알고리즘을 개선한 기법을 제안한다. 본 논문에서는 고유명사의 음성 오인식 교정 성능을 검증하였고, 그 결과 P@3의 결과가 비교 모델보다 55%의 성능 향상률을 보였다.

  • PDF

Imaging Characteristics of Plastic Scintillating Fiber Screens for Digital Mammography

  • Choi, Won-Young;Walker, James K.;Jing, Zhenxue
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.165-172
    • /
    • 1996
  • A scanning slot digital mammography system Luing a plastic scintillating fiber screen (SFS) is currently being developed To improve the x-ray interaction efficiency and absorption efficiency of an SFS, high Z elements can be added into the scintillating fiber core. In this paper, we investigated theoretically the zero spatial frequency detective quantum efficiency, DQE(0), and modulation transfer function, MTF(f), of three 2 cm thick SFSs made of polystyrene, polystyrene loaded with 5% by weight of lead, and polystyrene Loaded with 10% by weight of tin scintillating fibers. X-ray interaction efficiency, scintillating light intensity distributions and line spread functions were generated using Monte Carlo simulation. DQE(0) and MTF(f) were computed for x-ray energies ranging from 15 to 50 keV. Loading high Z elements into the SFS markedly increased the DQE(0). For x-ray energies used for mammovaphy, DQE(0) values of both high Z element loaded SFSs are about a factor of three higher than the DQE(0) of an Min-R screen. At mammographic x-ray energies, MTF(f) values of all three SFSs are Venter than 50% at 25 Ip/mm spatial frequency, and were found to be dominated by the 20 um individual scintillating fiber diameter used The results show that both hiP DQE(0) and spatial resolution can be achieved with the high Z element loaded SFSs, which make these SFSs attractive for use in a scanning slot detector for digital mammography.

  • PDF