• 제목/요약/키워드: In-water cleaning

검색결과 648건 처리시간 0.025초

The Effect on Fouling Reduction by the Ball Cleaning System in a Compressed Type Refrigerator

  • Lee, Yoon-Pyo;Karng, Sarng-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권2호
    • /
    • pp.88-96
    • /
    • 2002
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

중수로 핵연료 봉단마개의 저항업셋 용접을 위한 용접변수 (An Investigation of Welding Variables on Resistance Upset Welding for End Capping of HWR Fuel Elements)

  • 이정원;박춘호;고진현;정성훈;정문규
    • Journal of Welding and Joining
    • /
    • 제7권2호
    • /
    • pp.60-69
    • /
    • 1989
  • The present study was aimed at investigating the effect of welding parameters such as welding current, electrode force(or squeeze force) and parts cleaning on the sound weld, and establishing the most reliable weld conditions for HWP(Heavy Water Reactor) fuel end capping with the resistance upset butt welding. Major results obtained are as follows. 1. The amount of sound weld was increased with increasing weld current(5.0-11KA) because the activated diffusion with increasing heat generation played an important role in eliminating the porosity and weld line in the weld interface. 2. It was found that weld current was not significantly influenced by the electrode force although the increase of it caused a slight increase of weld current and upset deformation. 3. Acetone rinsing before drying for the Zircaloy-4 end cap cleaning produced the reliable sound weld because it would remove the remaining solvent and surface films, and provided the uniform contact between the end cap and the tube. 4. The optimum welding conditions for fuel end capping by a resistance upset hytt welding are obtained as follows. weld current: 10-11KA, electrode force: 62-90KPa parts cleaning: vapor degreasing.rarw.water, acetone rinsing.rarw.drying.

  • PDF

레미콘 세척수에 의한 토양의 중금속 오염 (Heavy Metal Contamination of Soil by Wash Water of Ready Mixed Concrete)

  • 오세욱;이봉직
    • 한국지반환경공학회 논문집
    • /
    • 제12권5호
    • /
    • pp.51-57
    • /
    • 2011
  • 일반적으로 레미콘(ready-mixed concrete(RMC))은 시간이 경과하면 굳게 되므로 드럼내부의 잔류 콘크리트를 세척해야만 한다. 이에 따라 발생하게 되는 레미콘 세척수는 일반 토양에 그대로 방류하게 될 경우 강한 알칼리성분과 중금속에 의한 수질오염으로 생태계에 영향을 미치게 된다. 레미콘 공장에서 세척수로 사용되는 물의 약 10~15%가 토양이나 하천으로 방류되고 있으나 이로 인한 구체적인 토양오염 보고는 미흡한 실정이다. 본 연구에서는 전국 레미콘공장의 세척수를 채취 분석하고 이를 여러가지 투수성을 가진 토양에 침투시켰을 때 토양에 잔류하는 중금속 성분과 pH성분을 분석하였다. 실험에 사용된 시료는 풍화토와 각각 입경이 다른 모래를 사용하였으며, 일정한 층 두께를 유지하고 24시간 동안 침투시켰다. 세척수는 침전 처리 전(슬러지수)과 침전처리 후(상등수)로 나누어 토양에 침투시켰으며, 슬러지수를 토양에 침투시킨 결과 Cu와 Mn, Fe, Zn이 23~90% 이상 잔류하는 것으로 나타났다. 그러나 침전 처리를 거친 상등수는 풍화토에서만 Cu와 Mn이 60%이상 잔류하는 것으로 분석되었다.

AODV 알고리즘을 이용한 정수시설의 모니터링 (Monitoring of The Advanced Water Treatment Using AODV Algorithm)

  • 배종일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2015-2016
    • /
    • 2011
  • Detection of data cleaning bed of because method of communication uses AODV(Ad hoc On-demand Distance Vector) Zig-Bee communication though communication method is important being separated by several part structurally data monitor ring do it way to understand be. Although data that detect in transmitter will get into several kinds, data of each senses is detected by 4 - 20 mA conclusively and remainder data is consisted of temperature data. That is measured in transmitter in mast baud via conversion relation to do monitorring norm of data being decided to PC mistake of measured value so that can do control between enforcement compose. Speak that can manage equipment of cleaning bed by number of persons who write if detect data detection in wide cleaning bed through Zig-Bee communication and is easy because also administration of data consists of real time.

  • PDF

정삼투 공정의 저에너지 고효율 세정을 위한 최적 유속 평가 (Optimal Flow Rate Evaluation for Low Energy, High Efficiency Cleaning of Forward Osmosis (FO))

  • 김이향;김정빈;잔민;민다혜;홍승관
    • 멤브레인
    • /
    • 제29권6호
    • /
    • pp.339-347
    • /
    • 2019
  • 정삼투 공정(forward osmosis, FO)은 역삼투 공정(reverse osmosis, RO)에 비해 저압으로 운영되므로 오염 제어, 유지 보수, 막 세정 및 잠재적 에너지 저감 측면에서 큰 이점이 있어 다양한 분야에 적용할 수 있는 기술이다. 특히, 정삼투 공정의 막오염층이 비교적 느슨하고 분산된 특성을 가지므로 역삼투 공정과 달리 물리세정만으로도 충분한 막오염 제어가 가능하다. 하지만 기존 연구들의 경우 정삼투 물리세정에 적합한 세정 유속을 적용하지 않아 최적화 운전을 하지 못했다는 한계가 있다. 따라서 이 연구는 경제적인 에너지량으로 높은 효율의 세정을 보일 수 있는 적절한 유속의 정당성 평가를 목적으로 한다. 정삼투 공정 막오염 실험을 8.54 cm/s 순환 유속으로 유지하고 세 가지 세정유속으로 회복률과 SEC (specific energy consumption) 비교 평가하였다. 이 실험의 결과로 2배속 세정이 3배속 세정의 수투과도 회복률 만큼의 높은 효율을 보이는 동시에, 2배속 세정이 높은 세정효율 및 경제적인 SEC를 보이는 적절한 유속이라는 것을 확인하였다.

레디믹스트 콘크리트 플랜트의 회수수 농도 측정 자동화에 관한 연구 (A Study on the Automatic Measurement of Solid Content in Recycled Water in Ready Mixed Concrete Plant)

  • 최영철;문규돈;조봉석
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.123-131
    • /
    • 2014
  • Whole amount of waste water, approximately 921.6 liter, for cleaning a ready mixed concrete truck should be used to produce concrete as a mixing water or cleaning water. Recycling water for concrete mixing contains solids, which cause decrease in slump, air and compressive strengths, so it may influence on poor concrete quality. Therefore, it has been maintained to use recycling water with less than 3 percent of solids. Since no evaluation system has been constructed to directly reflect on variability of recycling water from ready mixed concrete plants, it is necessary to develop "Automatic recycling solid measuring system" for quality controls in real time. In this research, sensors measuring waste water concentration in ultrasonic and inductance methods were developed, and automatic system using the sensors were established. The accuracy of measurement sensors developed for recycling water based on various conditions of concentration was proved, and application limits were evaluated. Also, concentration of recycling water using sensors developed from ready mixed concrete plant was measured, and curing method verified the accuracy of the sensors. Moreover, measurement sensors for recycling water in various locations were installed to evaluate the effects on measuring method and spots. The automatic measuring system for recycling water concentration, which is developed in the research, will contribute to improve concrete quality safety through reliable solids maintenance.

공동주택 지하저수조 내 침전된 부유성 고형물의 발생원인 및 제어방안 (Investigating the Causes and Control Measures for Precipitated Suspended Solids in the Underground Reservoir Tank in an Apartment)

  • 장준영;김주원;김기팔;신현상;임병란
    • 한국물환경학회지
    • /
    • 제39권2호
    • /
    • pp.153-161
    • /
    • 2023
  • The reservoir tank in an apartment is crucial for maintaining the quality of drinking water after it has undergone treatment. Investigating the water quality and potential contaminants in the reservoir tank is essential to ensure the safety of the drinking water. This study examined the water quality and precipitated suspended solids that accumulate at the bottom of the reservoir tanks in four apartments located in Gyeonggi province. As a result of the water quality investigation, turbidity increased proportionally to the distance from the water treatment plant (WTP) to the household. Heavy metals were also detected in the reservoir tank inlet but not in the water supplied from the WTP. The precipitated suspended solids (SS) in the reservoir tank contain high levels of heavy metals and total organic carbon (TOC). The precipitated SS mainly consists of Al, Mn, and Fe, which are expected to be a combination with turbidity-inducing substances. The X-ray diffraction (XRD) analysis revealed the presence of γ-FeO(OH), MnO2, and β-Fe2O3 in the SS. Additionally, F-EEM analysis indicates that the dissolved organic matter in the SS is mainly derived from a natural water source and microorganism activities, including metal-oxidizing bacteria and biofilms that can absorb metal ions. Based on these findings, several countermeasures can be taken to prevent the inflow of SS into the household, including regularly cleaning the reservoir tank, replacing or cleaning old pipes in the water supply system, and implementing monitoring and filtering systems to manage the SS.

전자빔 인출을 위한 2차전자방출 특성 연구 (Characteristics of Secondary Electron Emission for Electron Beam Extraction)

  • 우성훈;이홍식;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.204-206
    • /
    • 2003
  • Electron beam generator of cold cathode type has been developed for industrial application, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. The characteristics of secondary electron emission are studied by comparing total cathode current with ion current.

  • PDF

폐색 저감형 산기관의 개발 및 적용성 평가 (A study on the Development and Evaluation of Sludge Occlusion Reduced Diffuser)

  • 김영훈;김관엽;이의종;남종우;이창하;전민정;김형수
    • 상하수도학회지
    • /
    • 제25권1호
    • /
    • pp.41-49
    • /
    • 2011
  • The diffuser which is conventionally adapted to MBR, has problem that decreasing the cleaning effect of membrane module by inflexible air supply due to the occlusion of sludge from diffuser hole. To solve this problem, diffuser structure of submerged module should be improved to discharge sludge which is flow into the diffuser for prevent occlusion in the diffuser. In this study, the structure of the diffuser was reformed to open lower part for preclusion the blocking. And the outlet diameter of the diffuser was drawn through the condition for the depth of water and air rate, to prevent air-leak condition of improved diffuser. Moreover, application is evaluated by comparing test with occlusion effect of the conventional and improved diffuser. From the results, air-water boundary changes are steady with changes of water depth and it shows linear relation about air rate. By using this linear numerical formula, the height of diffuser's outlet can be decided. Also, it displays that it can prevent the occlusion effect during the comparing test. Hereafter, if this diffuser is applied to practical MBR process, the occlusion problem of diffuser will be disappeared.

나노마이크로 구조의 자기세정 기능성 코팅막의 제조 (Preparation of Self-Cleaning Coating Films with Nano- and Microstructure)

  • 정아롱;김준수;윤존도
    • 한국재료학회지
    • /
    • 제22권8호
    • /
    • pp.416-420
    • /
    • 2012
  • Recently nanoscience and nanotechnology have been studied intensively, and many plants, insects, and animals in nature have been found to have nanostructures in their bodies. Among them, lotus leaves have a unique nanostructure and microstructure in combination and show superhydrophobicity and a self-cleaning function to wipe and clean impurities on their surfaces. Coating films with combined nanostructures and microstructures resembling those of lotus leaves may also have superhydrophobicity and self-cleaning functions; as a result, they could be used in various applications, such as in outfits, tents, building walls, or exterior surfaces of transportation vehicles like cars, ships, or airplanes. In this study, coating films were prepared by dip coating method using polypropylene polymers dissolved in a mixture of solvent, xylene and non-solvent, methylethylketon, and ethanol. Additionally, attempts were made to prepare nanostructures on top of microstructures by coating with the same coating solution with an addition of carbon nanotubes, or by applying a carbon nanotube over-coat on polymer coating films. Coating films prepared without carbon nanotubes were found to have superhydrophobicity, with a water contact angle of $152^{\circ}$ and sliding angle less than $2^{\circ}$. Coating films prepared with carbon nanotubes were also found to have a similar degree of superhydrophobicity, with a water contact angle of 150 degrees and a sliding angle of 3 degrees.