• Title/Summary/Keyword: In-line monitoring

Search Result 1,355, Processing Time 0.029 seconds

Estimation Technique of Power Transmission Line Parameter by Phasor Measurement Units (송전선로 파라메터 정밀 예측을 위한 페이저 측정기의 응용)

  • Cho, Ki-Seon;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.193-195
    • /
    • 2003
  • This paper presents an approach to estimate the power transmission line parameter by phasor measurement units(PMUs), which are synchronized to 1 pps signal of GPS. Existing approaches to estimate power transmission line parameter, are mainly off-line ones, based on faults or switching events on other neighboring lines. In this paper, to obtain static and dynamic properties of power transmission line parameter in service, the prototype of pmu-based Transmission Line Parameter Monitoring System (TLPMS) is proposed. Also, an technique to estimate parameters of transmission line described as 2-port network model and the soundness of estimated parameters are addressed.

  • PDF

Development of a Flow Injection Analysis Technique for On-line Monitoring of Xylitol Concentrations (자일리톨 농도의 온라인 모니터링을 위한 흐름주입분석기술 개발)

  • 이종일
    • KSBB Journal
    • /
    • v.17 no.4
    • /
    • pp.339-344
    • /
    • 2002
  • Flow injection analysis technique for monitoring of xylitol concentrations in biological processes has been developed using xylitol oxidase (XYO) immobilized on VA-Epoxy Biosynth carrier. The immobilized XYO cartridge has been integrated into a FIA system with an oxygen electrode and systematically investigated with regards to the factors which can affect the activity of the immobilized XYO, such as pH, temperature, salt concentration etc. The activity of the immobilized XYO increased with the temperature ($19.0 - 29.0^{circ}C$) and sample injection volume ($75-250\muL$) and molarity of potassium phosphate buffer (0.1-1 M), but it reached the highest value at pH 8.5. The XYO-FIA system has been also applied for on-line monitoring of xylitol concentrations in a reactor and showed good operational stability and agreement with off-line data measured with HPLC.

A Study on Development of On-line Condition Monitoring Program of a Turboshaft Engine (터보샤프트 엔진의 온라인 상태감시 프로그램 개발에 관한 연구)

  • Kong, Chang-Duk;Kho, Seong-Hee;Ki, Ja-Young;Gu, Young-Joo;Jun, Yong-Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.6
    • /
    • pp.7-11
    • /
    • 2008
  • The helicopter flies at low level flight mode in its own operational range comparing to other aircraft categories. The low level flight means that the engine operates at variable atmospheric condition such as hot and cold temperature, snow, heavy rain, etc. Furthermore it may increase the entering possibility of engine foreign object damage particles like sand, dust, etc., i.e. this operating condition gives rise to damages of engine gas path components. An on-line condition monitoring program was developed by using SIMULINK, where measurement signals were simulated as an input module. The reliability and capability of the developed on-line condition monitoring were confirmed through application to a real helicopter engine health monitoring.

A Study on Development of On-line Condition Monitoring Program of a Turboshaft Engine (터보샤프트 엔진의 온라인 상태감시 프로그램 개발에 관한 연구)

  • Kong, Chang-Duk;Gu, Young-Joo;Kho, Seong-Hee;Ki, Ja-Young;Jun, Yong-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.163-166
    • /
    • 2008
  • The helicopter flies at low level flight mode in its own operational range comparing to other aircraft categories. The low level flight means that the engine operates at variable atmospheric condition such as hot and cold temperature, snow, heavy rain, etc. Furthermore it may increase the entering possibility of engine foreign object damage particles like sand, dust, etc., i.e. this operating condition gives rise to damages of engine gas path components. An on-line condition monitoring program was developed by using SIMULINK, where measurement signals were simulated as an input module. The reliability and capability of the developed on-line condition monitoring were confirmed through application to a real helicopter engine health monitoring.

  • PDF

Carbon fiber-based long-gauge sensors monitoring the flexural performance of FRP-reinforced concrete beams

  • Mohamed A. Saifeldeen;Nariman Fouad
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.4
    • /
    • pp.299-314
    • /
    • 2023
  • Long-gauge carbon fiber line (CFL) sensors have received considerable attention in the past decade. However, there is still a need for an in-depth investigation of their measuring accuracy. This study investigates the accuracy of carbon fiber line sensors to monitor and differentiate the flexural behavior of two beams, one reinforced with steel bars alone and the other reinforced with steel and basalt fiber-reinforced polymer bars. A distributed set of long-gauge carbon fiber line, Fiber Bragg Grating (FBG), and traditional strain gauge sensors was mounted on the tensile concrete surface of the studied beams to compare the results and assess the accuracies of the proposed sensors. The test beams were loaded monotonically under four-point bending loading until failure. Results indicated the importance of using long-gauge sensors in providing useful, accurate, and reliable information regarding global structural behavior, while point sensors are affected by local damage and strain concentrations. Furthermore, long-gauge carbon fiber line sensors demonstrated good agreement with the corresponding Fiber Bragg Grating sensors with acceptable accuracy, thereby exhibiting potential for application in monitoring the health of large-scale structures.

VALIDATION OF ON-LINE MONITORING TECHNIQUES TO NUCLEAR PLANT DATA

  • Garvey, Jamie;Garvey, Dustin;Seibert, Rebecca;Hines, J. Wesley
    • Nuclear Engineering and Technology
    • /
    • v.39 no.2
    • /
    • pp.133-142
    • /
    • 2007
  • The Electric Power Research Institute (EPRI) demonstrated a method for monitoring the performance of instrument channels in Topical Report (TR) 104965, 'On-Line Monitoring of Instrument Channel Performance.' This paper presents the results of several models originally developed by EPRI to monitor three nuclear plant sensor sets: Pressurizer Level, Reactor Protection System (RPS) Loop A, and Reactor Coolant System (RCS) Loop A Steam Generator (SG) Level. The sensor sets investigated include one redundant sensor model and two non-redundant sensor models. Each model employs an Auto-Associative Kernel Regression (AAKR) model architecture to predict correct sensor behavior. Performance of each of the developed models is evaluated using four metrics: accuracy, auto-sensitivity, cross-sensitivity, and newly developed Error Uncertainty Limit Monitoring (EULM) detectability. The uncertainty estimate for each model is also calculated through two methods: analytic formulas and Monte Carlo estimation. The uncertainty estimates are verified by calculating confidence interval coverages to assure that 95% of the measured data fall within the confidence intervals. The model performance evaluation identified the Pressurizer Level model as acceptable for on-line monitoring (OLM) implementation. The other two models, RPS Loop A and RCS Loop A SG Level, highlight two common problems that occur in model development and evaluation, namely faulty data and poor signal selection

A Development of Surface Temperature Monitoring System for Underground Tunnel Cable Joint using Wireless Sensor (무선센서를 이용한 지하전력구의 케이블 접속함 표면온도감시시스템 개발)

  • Kim, Young-Il;Song, Jae-Ju;Shin, Jin-Ho;Yi, Bong-Jae;Cho, Seon-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1879-1884
    • /
    • 2007
  • In the electric power industry, it is important that the supply of energy must be guaranteed. Many power utilities control and supervise the transmission line to avoid power failures. In case of underground tunnel, some troubles are reported in cable joint. To stabilize the power, it is needed to monitor the cable joint. Many researches of cable joint monitoring have been going on by partial discharge measurement and temperature measurement using optical cable. These methods need much cost to install and maintain, so it is only used in critical transmission line. In this research, we use wireless sensor technology, because of its low cost and easy installation. We develop the temperature monitoring system for cable joint. Temperature sensor is installed on the surface of cable joint and sends data to server through router node using wireless network. Generally Ad hoc routing is searched in wireless network. However, in this research, we design the static linear routing mechanism, which is suitable for electric power line monitoring and analyze the life time of the sensor node by measuring the amount of the battery consumption.

Development of Fiber-Optic AE Sensor for On-Line Monitoring System (광섬유를 이용한 상시감시 시스템용 음향방출센서의 개발)

  • Nam, Jae-Yeong;Jeong, Jae-Hyeon;Choe, Jae-Bung;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.12
    • /
    • pp.2891-2898
    • /
    • 2000
  • The objective of this paper is to develop a fiber-optic acoustic emission(AE) sensor applicable to on-line monitoring systems which is suitable for long-distance signal transmission. An AE sensor was developed by use of a fiber-optic cantilever and an extrinsic Fabry-Perot interferometer(EEPI). The efficiency of signal processing was improved by driving the high frequency AE signals into the low frequency ones. In order to verify the developed sensor, the tensile and the pencil lead fracture(PLF) tests were performed including the experiment showing the Kaiser effect. Form tests, AE signals were successfully detected in the elastic-plastic deformation range, especially higher signals at the crack propagation. The developed sensor was expected to be used for an on-line monitoring of crack propagation in mechanical system.

A Study on the Wear Detection of Drill State for Prediction Monitoring System (예측감시 시스템에 의한 드릴의 마멸검출에 관한 연구)

  • 신형곤;김태영
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.2
    • /
    • pp.103-111
    • /
    • 2002
  • Out of all metal-cutting process, the hole-making process is the most widely used. It is estimated to be more than 30% of the total metal-cutting process. It is therefore desirable to monitor and detect drill wear during the hole-drilling process. One important aspect in controlling the drilling process is monitoring drill wear status. There are two systems, Basic system and Online system, to detect the drill wear. Basic system comprised of spindle rotational speed, feed rates, thrust torque and flank wear measured by tool microscope. Outline system comprised of spindle rotational speed feed rates, AE signal, flank wear area measured by computer vision, On-line monitoring system does not need to stop the process to inspect drill wear. Backpropagation neural networks (BPNs) were used for on-line detection of drill wear. The output was the drill wear state which was either usable or failure. This paper deals with an on-line drill wear monitoring system to fit the detection of the abnormal tool state.

Application of On-line Diagnostic System for Oil-filled Power Transformers (대용량 변압기 예방진단 시스템 적용 사례)

  • Kim Y.H.;Lee C.R.;Hwangbo S.W.;;Shin Y.T.;Park K.S.;Lee J.B.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.590-593
    • /
    • 2004
  • This paper presents recent trends on the on-line monitoring and diagnostic systems for oil-immersed transformers. Specially, our system on YeoSu thermal power plant is introduced for high sensitivity and accuracy of ours. It is combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF