• Title/Summary/Keyword: In-line Valve

Search Result 195, Processing Time 0.027 seconds

Analysis and Design of Micro Solenoid (마이크로 솔레노이드의 해석 및 설계)

  • Jeon, Y.S.;Bae, S.K.;Kim, D.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.4
    • /
    • pp.14-20
    • /
    • 2006
  • Recently, the on-off solenoid valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for on-off solenoid valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate on-off solenoid valve using the analogy of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, flow field characteristics was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D simulation using distribution curve of the force by working the front poppet.

  • PDF

Improvement of the Degreasing Performance of Surface Treating Steel Sheet by the Automatic Control of Alkaline Degreasing Process (알칼리탈지공정 자동화관리에 의한 표면처리용 강판의 탈지능 향상)

  • 박노범;박대수;박정렬;유민수
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.2
    • /
    • pp.132-139
    • /
    • 1996
  • Experiments on the automatic control of NaOH concentration and on the spraying condition of NaOH solution in the alkaline degreasing process of a continuous hot-dip galvanizing line have been carried out in order to improve degreasing performance of a galvanizing sheet steel using laboratory degreasing and galvanizing simulators. The concentration of NaOH for the good degreasing has been determined to be 6.0% and more and this concentration has been able to be automatically well controlled within $\pm$0.1% by employing a solution electrical conductivity meter under a flow injection analysis condition rather than by employing a sodium ion selective electrode in the degreasing simulator. Frequent blocking of the spraying nozzles of the solution has been reduced considerably by the set-up and periodical operation of an automatic valve system in the nozzle system. By applying this automatic valve system and by automatic controlling the NaOH concentration and other ordinary variables in the degreasing process, the degreasing performance has been increased from the conventional 76% to the new 85%.

  • PDF

Calculation of Losses in VSC-HVDC based on MMC Topology

  • Kim, Chan-ki;Lee, Seong-doo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.47-53
    • /
    • 2018
  • VSC technology is now well established in HVDC and is, in many respects, complementary to the older Line Commutated Converter (LCC) technology. Despite the various advantages of VSC technology, VSC HVDC stations have higher power losses than LCC stations. Although the relative advantages and disadvantages are well known within the industry, there have been very few attempts to quantify these factors on an objective basis. This paper describes methods to determine the operating losses of every component in the valve of VSC-HVDC system. The losses of the valve, including both conduction losses and switching losses, are treated in detail.

Design and Characteristic of the AC Solenoid Valve (AC 솔레노이드 밸브의 설계 및 특성)

  • Kim, Dong-Soo;Jeon, Yong-Sik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3056-3061
    • /
    • 2007
  • The technology of AC solenoid valves is now considered as a core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for medical applications. And AC solenoid valves, which operate by compressed air, are characterized by high speed response, great repeatability and that the pressure on the cross sectional area of poppet is kept constant regardless of the fluctuation of the pressure exerted on the ports. In this study, AC solenoid valves that posses the high-speed responsibility and the high rate of flow have designed and analyzed through the law of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, Flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

Assessment of Internal Leak on RCS Pressure Boundary Valves (원자로냉각재계통 압력경계밸브 내부누설 평가)

  • Park, Jun-Hyun;Moonn, Ho-Rim;Jeong, Ill-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.322-327
    • /
    • 2001
  • The internal leaks of RCS pressure boundary valves may cause thermal fatigue crack because of the TASCS in RCS branch line. After experienced unisolable piping failures in several PWR plants, many studies have peformed to understand these phenomena and various methods were applied to ensure the structural integrity of piping. In this paper, the cause of unisolable piping failures and the alternatives to prevent recurrence of failure were reviewed. Also, the severity of piping failure including susceptibility of valve leaks was evaluated for the Westinghouse 2-loop plant. The length of turbulent penetration on RHR inlet piping was measured and, thermal fluid analysis and fatigue analysis was performed for this piping. As a means of ensuring the structural integrity, temperature monitoring and specialized UT and other alternatives were compared for the further application.

  • PDF

에너지 절약형 공기압 제어시스템 특성해석

  • 박재범;김동수;김형의;김기홍;염만오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.635-641
    • /
    • 1994
  • Recently, Improving the energy efficiency of a pneumatic system and reducing the consumption of compressed air were a concern of scholars at domestic and abroad. The using fields of a pneumatic system are widely used in factory automation of manufacturing line, chemical factories with explosiveness danger and petroleum industries etc. In particular, Pneumatic cylinder is applied to feeding work of workpiece, jig tools and press mechanism, reciprocation and rotary motion with rack and pinion. In this study, The experimental apparatus consisted to pneumatic cylinder, dual supply pressure regulator and solenoid valve. The dual supply pressure regulator connected to outlet port of solenoid valve. The supply pressure (4.5kgf/cm$\^$2/) of compressed air goes into the rodless chamber 1 to drive the pistion rod forward which is named working stage. The supply pressure(2kgf/cm$\^$2/) of compressed air goes into the rod chamber 2 to drive the piston rod backward which is named no-working stage. Accordingly, The research results of this study can be obtained to Energy-Saving Effects of the compressed air about 35%.

  • PDF

Identification of Noise Source from Main Steam Line in Power Plant (발전소 주증기 배관 소음 발생 원인 규명)

  • Sohn, M.S.;Lee, J.S.;Lee, S.K.;Lee, W.R.;Lee, S.K.
    • Journal of Power System Engineering
    • /
    • v.7 no.3
    • /
    • pp.23-28
    • /
    • 2003
  • In heavy nuclear power plant, high energy through main steam line is provided to turbine that generate the electric power. Since plant had generated power, high noise has been occurred. Noise make equipments and work environment worse. For finding out the location and the cause of making noise, noise was measured along main steam line at open/close test of Main Steam Isolation Valve (MSIV hereafter). As the result, it was identified that the vortex shedding in the cavity of MSIV is main noise source. The profile change of MSIV seat ring was proposed as the method of noise reduction. After filletting MSIV seat ring, the noise level reduced $10{\sim}20dB$ compared before the change of profile.

  • PDF

Effects of gas pulsation in the suction line of a hermetic reciprocating compressor on th compressor performance (밀폐형 왕복동 압축기에서 흡입라인 가스맥동이 압축기 성능에 미치는 영향)

  • Lee, Yong-Ho;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.404-409
    • /
    • 2007
  • For a hermetic reciprocating compressor, it has been known that the gas pulsation in the suction line affects the compressor performance, and suction muffler design has been focused on both of noise reduction and minimum pressure drop across the muffler. Some studies have been carried out on the mutual interaction between the gas pulsation and the cylinder pressure to investigate some supercharging effects, but their efforts were limited on rather simple geometries. In this paper, interaction of the gas pulsation in the compressor suction line with cylinder pressure via suction valve motion has been calculated; for the gas pulsation analysis, modeling of Helmholtz resonators in series was used, and for cylinder pressure calculation, energy equations was set up for the gas inside the cylinder. For demonstration of this calculation method, four different types of suction line configurations for a hermetic reciprocating compressor were compared in terms of compressor performance and gas pulsation level.

  • PDF

Life Analysis of Pneumatic Valve (공기압 밸브의 수명 분석)

  • Kang, Bo-Sik;Lee, Seung-Hun;Kim, Kyung-Soo;Lim, Nam-Gu;Kim, Hyoung-Eui
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1848-1853
    • /
    • 2007
  • In this study, we are to analyze the life and the main failure mode of pneumatic valves that are usually applied to the factory automation line. Pneumatic valves have complicated failure cause since they are organized as a complex of various elements. Therefore, in this paper, we analyzed the main failure mode of pneumatic valves, and then performed life test and performance test according to the international standards. On the basis of these processes, we estimated a shape parameter that is the main factor for the calculation of test time for the reliability of pneumatic valves by analyzing life distribution data.

  • PDF

A Study on Valve-Induced Water Hammer Characteristics for Large Pump System (밸브에 의한 대형펌프시스템의 수격특성에 관한 연구)

  • Lee, C.J.;Lim, K.S.;Cho, D.H.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2009.06a
    • /
    • pp.177-178
    • /
    • 2009
  • Hydraulic Transients would be occurred since pressure is increased or decreased when water speed inside of pipeline is rapidly changed A study on water hammer has become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. In this study, the method of characteristic line was adopted to evaluate the valve-induced water hammer phenomena in a pumps feedwater system.

  • PDF