Assessment of Internal Leak on RCS Pressure Boundary Valves

원자로냉각재계통 압력경계밸브 내부누설 평가

  • Published : 2001.06.27

Abstract

The internal leaks of RCS pressure boundary valves may cause thermal fatigue crack because of the TASCS in RCS branch line. After experienced unisolable piping failures in several PWR plants, many studies have peformed to understand these phenomena and various methods were applied to ensure the structural integrity of piping. In this paper, the cause of unisolable piping failures and the alternatives to prevent recurrence of failure were reviewed. Also, the severity of piping failure including susceptibility of valve leaks was evaluated for the Westinghouse 2-loop plant. The length of turbulent penetration on RHR inlet piping was measured and, thermal fluid analysis and fatigue analysis was performed for this piping. As a means of ensuring the structural integrity, temperature monitoring and specialized UT and other alternatives were compared for the further application.

Keywords