• 제목/요약/키워드: In-kind Transfer

검색결과 249건 처리시간 0.027초

In Vitro Fertilization and Development of Frozen-thawed Bovine Follicular Oocytes (동결융해 소 난포란의 체외발생에 관한 연구)

  • 윤종택;이호준;한기영
    • Journal of Embryo Transfer
    • /
    • 제13권2호
    • /
    • pp.191-197
    • /
    • 1998
  • Immature nocytes and in VitrO matured Oocytes collected from the slaughtered Korean cattle were frozen slowly with 10% ethylene glycol+5% polyvinyl pyrolidine+0.05M trehalose (l0EPT), 10% ethylene glycol+5% ficoll+0.05M sucrose (1OEFS), or 10% ethylene glycol+5% ficoll+0.05M trehalose (l0EFT) by cell freezer (experiment 1). And also,They were ultra-rapidly frozen with 30% ethylene glycol+10% polyvinyl pyrolidine+0.5M trehalose (3OEPT) or 30% ethylene glycol+18% ficoll+0.5M sucrose (3OEFS) using electron microscope grid (experiment 2). In experiment 1, the cleavage rate was 23.0% when immature oocytes were frozen slowly using various cryoprotectants descrihed above, and 5.1% of cleaved oocytes developed to over morula stage after in Vitro fertilization (IVF). There were no significant differences among these groups. When matured oocytes were frozen slowly, the total cleavage rate was 19.7%, and over morula stage was 3.2%. lOEPT (4.8%) and EFS (4.4%) were slightly more effective than l0EFT (0.0%) for development in vitro. Only in l0EFT treated group, immature oocytes have higher developmental capacity than matured ones, when they were frozen slowly and IVF after thawing. In experiment 2, oocytes were ultra-rapidly frozen using the electron microscope grid with two kind of cryoprotectants described above. In immature oocyte group, the cleavage rate was 13.9% and 5.8% of cleaved oocytes developed to over morula stage after IVF, and in matured group, 25.7 and 7.6%, respectively. There were no significant differences between two kind of cryoprotectants, but in ultra-rapid freezing using electron microscope grid, the efficiency is slightly higher in matured oocyte group.

  • PDF

The Effect to a Sense of Safety by Training the Transfer Method of Paralytic on the Guardians of Paralytic: A Preliminary Study (마비 환자 보호자의 환자 이동 방법 교육이 안위감에 미치는 효과에 대한 예비 조사)

  • Park, Jum-mi
    • Journal of Digital Convergence
    • /
    • 제20권5호
    • /
    • pp.885-890
    • /
    • 2022
  • This research is to consider the training effect of effective paralytic transfer method and reduce the risk of paralytic transfer. It was questioned and interviewed the guardians of 50 patients agreed this research among the guardians of patient who hospitalized in rehabilitation ward. The contents of questions was safety grade with 1~10 point which the guardians of paralytic was feeling in case transfer the patient of paralytic. The sense of safety before and after the traning of transfer method was improved about 25% more from 5.81 point to 7.26 point on the safety. The 98% of subjector supported the needs of training for transfer method of paralytic. And also 74% of subjector replied that the safety was improved after taking the training. On the base of this research, it is needed to review this kind of traning to get reliability and propriety throuth repeatitive research.

Numerical Study on the Performance of a Microchannel Heat Exchanger with a Novel Channel Array (새로운 채널 배열을 통한 마이크로채널 열교환기 성능 향상 수치 연구)

  • Jeon, Seung-Won;Lee, Kyu-Jung;Moon, Dong-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제35권11호
    • /
    • pp.1119-1126
    • /
    • 2011
  • In conventional microchannel heat exchangers, only one kind of fluid (hot or cold) flows in each plate. The channels contain different kinds of fluid depending on the vertical position, but they have the same kind of fluid at all horizontal positions. Therefore, there is a slower heat transfer rate in the horizontal direction than in the vertical direction. We propose a microchannel heat exchanger in which hot and cold fluid flows alternately in each plate to improve the thermal performance. This novel channel array requires a special design for the inlet and outlet. The proposed channel array has a faster heat transfer rate than a conventional channel array. The thermal performance of the novel channel array increases with increasing Reynolds number and Prandtl number, but it decreases as the ratio of solid to fluid thermal conductivity increases.

A Study on the Thermal Performance of Embossing Surface Sandwich Panel During the Summer (여름철 엠보싱 샌드위치 패널의 열적 성능에 관한 연구 -평판 샌드위치 패널과 비교를 중심으로-)

  • 손철수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제12권10호
    • /
    • pp.917-924
    • /
    • 2000
  • The purpose of this research is to investigate the thermal performance of embossing surface sandwich panel and flat surface sandwich panel during the summer. To do this research, thermal performances in summer season at the six points of embossing surface sandwich panel and flat surface sandwich panel are investigated focusing on the temperature. Three kinds of embossing surface sandwich panel and one kind of flat surface sandwich panel are used for this research. At the same size of sandwich panel, the average temperature differences of flat surface sandwich panel between average temperature at the 0.5 mm below copper plate and average outside air temperature and surface temperature are higher than those of embossing surface sandwich panel. The average heat transfer rate of flat surface sandwich panel is higher than that of embossing surface sandwich panel. More study will be needed about the size of diameter and height of embossing, and materials of embossing surface sandwich panel.

  • PDF

Development of Analysis Model for Down Scaled Two Phase Catalytic Reactor (초소형 촉매 이상 분해 반응기 해석 모델 개발)

  • Lee, Dae-Hoon;Kwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제28권1호
    • /
    • pp.24-30
    • /
    • 2004
  • Analysis model for the two-phase catalytic reactor is presented. With the progress in development of micro thermofluidic devices, needs fur understanding of the phenomena in two phase reaction in cm scale has been arisen. To investigate thermal and reactive performance of down scaled two phase reactor simple analysis model that is a kind of lumped flow model is proposed. Analysis model presented is based on the experiment on mm scale model reactor. Target experiment is catalytic decomposition of 70wt% hydrogen peroxide with existence of perovskite L $a_{0.8}$S $r_{0.2}$Co $O_3$ catalyst. It is composed of balance equations of mass and energy. Each phase is considered to be a species fur the simplicity. Axial diffusion and transversal distribution of properties are neglected. Two phase catalytic reaction is modeled as successive gasification of liquid lump around catalyst and reaction in gas phase. Heat transfer is modeled by model function ofNu number. Modeled Nu is expressed as Nu=N $u_{0}$ (1+ $a_1$( $a_2$ $T^{-}$ $a_3$)exp( $a_4$ $T^{-1}$)exp( $a_{5}$ z). Transfer coefficients are determined by the comparison of experimental results. With the model, heat transfer characteristics are investigated. Also by the mass transfer coefficient, characteristics in mass transfer is investigated. With the result basic understanding on design and analysis of mm scale two-phase reactive device is obtained. Also it can be further applied to micro scale reactive device fabricated by micromachining.ing..

Photonic K-Band Microwave Bandpass Filter with Electrically Controllable Transfer Characteristics Based on a Polymeric Ring Resonator (전기적으로 가변되는 전달특성을 갖는 폴리머 링 광공진기를 이용한 마이크로웨이브 대역통과 필터)

  • Kim, Gun-Duk;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • 제17권5호
    • /
    • pp.475-479
    • /
    • 2006
  • An integrated photonic K-band microwave bandpass filter has been proposed and demonstrated by incorporating a polymeric ring resonator. Its transfer characteristics were adjusted by shilling the resonance wavelength of the ring resonator via the thermooptic effect. The achieved performance of the filter includes the center frequency of 20 GHz, the attenuation of ${\sim}15dB$, the bandwidth of 2 GHz, and the corresponding quality factor of 10. The microwave output power within the passband of the device was adjusted at the rate of about 6.7 dB/mW in the range of 27 dB. This kind of device with electrically controllable transfer characteristics can be applied to implement microwave switches and other devices.

A Simulation Study on the Transfer Characteristics of the Talbot Pattern Through Scintillation Screens in the Grating Interferometer (격자 간섭계에서 탈봇 패턴의 섬광체 스크린 투과 시 전달 특성에 대한 시뮬레이션 연구)

  • Kim, Daeseung;Kim, Youngju;Lee, Seho;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • 제42권1호
    • /
    • pp.67-75
    • /
    • 2019
  • Grating interferometry based imaging technology is a kind of radiation imaging system, which can acquire not only absorption image but also phase difference and dark field image using the Talbot pattern. However, because of the technological difficulties and high cost of fabricating the gratings that make up the system, much efforts are being made to look for ways to replace them. The is a preliminary study to see how the Talbot pattern transfer through various kinds of scintillators and if the optical grating can be a way to replace the conventional absorption gratings. The geometry of the interferometer, the scintillator model, and the scintillator thickness are the main inputs for our simulation. We have used the concept of modulation for quantitative analysis of the contrast ratio of the Talbot pattern. This research is expected to provide very useful information on the design of optical gratings, which is an alternative way to analyze the Talbot pattern, which we have filed a patent on.

The Experimental Study of Various Salts on the Characteristics of Heat Transfer in Indirect Moxibustion with Salt (염(鹽)의 종류(種類)에 따른 격염구(隔鹽灸)의 열전달(熱傳達) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Geon-mok;Lee, Gun-hyee;Seo, Eun-mi
    • Journal of Acupuncture Research
    • /
    • 제21권1호
    • /
    • pp.119-135
    • /
    • 2004
  • Objective: The purpose of this study is to investigate the mechanism and effect of moxibustion with salt objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with salt. Methods: We have selected of the moxibustion with salt of indirect moxibustion. We make a comparative study of the thermodynamic characteristics of moxibustion with salt as a kind of the 4 salt. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results: 1. We make out that it is not significantly change the time of thermal conduction of moxibustion with salt as a kind of 4 salt. 2. The heating period of Refined Salt was long and that of Sun-dried Salt was a short time respectively. The heating period of maximum tamperature is high Sun-dried Salt, Mechanical Salt and Refined Salt orderly. Maximun heating speed in the heating period was $0.151{\sim}0.184^{\circ}C/sec$ and at the same tendency of the maximum temperature in the heating period. 3. The retaining period was shorter than the heating period respectively, that is 15~24% of the combustion time of in the heating period. We make out that it is not significantly different the time of the retaining period as a kind of 4 salt. The mean temperature of retaining period was $43.2{\sim}48.1^{\circ}C$, that was extraordinarily high temperature. 4. We make out that it is not significantly different the time of the cooling period as a kind of 4 salt. The cooling period was measured 223~233sec. Beacuse the same density and size of moxa combustion was made an experiment. 5. The effective combustion time of Refined Salt is longer(259sec) than that of Sun-dried Salt(173sec). It is significantly different the time of the combustion time as a kind of 4 salt. 6. It is significantly different the Sample deviation of the combustion time as a kind of 4 salt because of the water content of the 4 salt individually. Conclusions: As the base on this study, we obtained the conclusion as the follows. The salt of moxibustion with salt was fitted for Sun-dried Salt due to making to Mechanical Salt recently. The Refined Salt is composition rate to another and small size comparatively. So It was fitted for the salt of moxibustion with salt. It is necessary to study continuously about the more suitable moxibustion with salt and quantitative analysis about the moxibustion with salt.

  • PDF

ANALYSIS OF WAVE VELOCITY FOR TEMPERATURE PROPERGATION IN A MECHANICAL FACE SEAL (기계평면시일에서 온도전파를 위한 파속도의 이론적해석)

  • 김청균
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 한국윤활학회 1987년도 제5회 학술강연회초록집
    • /
    • pp.50-56
    • /
    • 1987
  • A mechanical face seal is most commonly used to seal liquids and gases at various speeds, pressures and temperatures. The primary seal ring is in sliding contact with the seal seat and as a result heat in the vicinity of the interface is generated. Local temperatures at points along the circumferential direction will fluctuate as asperities on the surfaces pass. This kind of fluctuation of temperature has been investigated to take place. This may lead to the hot spots phenomenon between the contacting asperities. Sibley and Allen showed photographic evidence of systemically moving hot spots in the contact zone. The appearance of such a temperature disturbance has been attributed to a kind of thermoelastic instabilities between two surfaces: This involves a feedback loop which comprises localized elevation of frictional heating, resultant localized thermal bulding, localized pressure increase as the result of the bulging and futher elevation of frictional heating as the result of the pressure increase. The heating of hot spots will be continued until the expanded material due to the frictional heating is worn off. Therefore to predict the speed of temperature propagation into the body is essential to the analysis of heat transfer on the edge of the seal.

  • PDF

A Study on the Measurement System Design for the Resin Flow and Curing in the Vacuum Assisted Resin Transfer Molding(VARTM) Process Using the Long Period Fiber Bragg Grating (삽입된 장주기 광섬유 격자를 이용한 VARTM 공정에서의 수지이동 및 변형 과정 예측 시스템 설계에 관한 연구)

  • Yoon, Young-Ki;Chung, Seung-Hwan;Lee, Woo-Il;Lee, Byoung-Ho;Byun, Joon-Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제28권5호
    • /
    • pp.489-494
    • /
    • 2004
  • Long Period Gratings (LPG) is currently receiving considerable attention because of their consistent measuring results fur pressure, temperature, strain and flow. LPG is easier to prepare and has a high sensitivity compared with Fiber Bragg Gratings (FBG). In addition, this kind of optical fiber sensors could be used for implementations in various structures. In this paper, LPG was used to monitor in situ the resin flow and the curing process in VARTM (Vacuum Assisted Resin Transfer. Molding). In order to demonstrate the effectiveness of the method, FBG is inserted into the glass mat to monitor the resin flow using optical spectrum analyzer (OSA). The curing reactions in VARTM are also observed using the same method. From the results, the attenuation wavelength shift and the loss change of attenuation band can be obtained from the status of the RTM (Resin Transfer Molding) sample owing to the internal variations of the .effective index, temperature, and pressure. It is shown that the proposed LPG is more effective in monitoring the curing reaction than FBG.