• 제목/요약/키워드: In-grid Condition

검색결과 592건 처리시간 0.034초

AN ADAPTIVE FINITE DIFFERENCE METHOD USING FAR-FIELD BOUNDARY CONDITIONS FOR THE BLACK-SCHOLES EQUATION

  • Jeong, Darae;Ha, Taeyoung;Kim, Myoungnyoun;Shin, Jaemin;Yoon, In-Han;Kim, Junseok
    • 대한수학회보
    • /
    • 제51권4호
    • /
    • pp.1087-1100
    • /
    • 2014
  • We present an accurate and efficient numerical method for solving the Black-Scholes equation. The method uses an adaptive grid technique which is based on a far-field boundary position and the Peclet condition. We present the algorithm for the automatic adaptive grid generation: First, we determine a priori suitable far-field boundary location using the mathematical model parameters. Second, generate the uniform fine grid around the non-smooth point of the payoff and a non-uniform grid in the remaining regions. Numerical tests are presented to demonstrate the accuracy and efficiency of the proposed method. The results show that the computational time is reduced substantially with the accuracy being maintained.

5×5 핵연료 모의 집합체의 지지격자 스트랩 진동특성 (The Grid Strap Vibration Characteristics of the 5×5 Nuclear Fuel Mock-up)

  • 김경홍;박남규;김경주;서정민
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.619-625
    • /
    • 2012
  • Since the fuel is always exposed to turbulent flow, the grid strap shows flow induced vibration characteristics that impact on the nuclear fuel soundness. The dynamic behavior of grids in nuclear fuels is quite complex, since two pairs of spring and dimple support are contacted with rods by friction in the limited space. This paper focuses on investigation of the grid strap(test fuel strap, TFS) vibration in one cell. TFS consists of a single spring and double dimples. To identify the grid strap vibration, modal analysis of the strap is performed using finite element method(FEM). Modal testing on a $5{\times}5$ grid structure without rods is performed. The modal testing results are compared to analytic results. In addition, random test considering rod effect is performed about a $5{\times}5$ grid with rods under real contact condition in the air. Finally, the strap vibration of a $5{\times}5$ fuel bundle in investigation of flow induced vibration(INFINIT) facility is measured in real fluid velocity condition without heating. It is shown that modal frequencies from the test are almost equal to those peak frequencies in the INFINIT test.

포토에칭법에 의한 Digitron용 Grid제조에 관한 연구 (The Fabrication of Digitron Grid by Photoetching Process)

  • 김만;이종권
    • 한국표면공학회지
    • /
    • 제29권1호
    • /
    • pp.60-72
    • /
    • 1996
  • A photoetching process is widely used for small and high precision parts in machinery, electronic and semi-conductor industries. One of the high precision parts, grid is very important part of digitron which use electron display, and it is fabricated by only photoetching process because of high precision. In this study, to develop high precision digitron grid, characteristics of etching solution were investigated with electrochemical test, that was potentiodynamic test and immersion test in the ferric chloride solution and added some additives. Based on the electrochemical etching test, grid was fabricated by continuous photoetching process at various etching condition. From the result of measured line width and etching depth under-cut and etching factor were calculated. For the fabrication of 25$\mu\textrm{m}$ line width, optimal etching condition was etching temperature 40~$45^{\circ}C$, spray pressure 1.5kg/$\textrm{cm}^2$ and etching time 3~4min.

  • PDF

경수로 원전연료용 질칼로이 지지격자체의 LASER 용접품질 평가(III) (Welding Quality Evaluation on the LASER Welding Parts of the Zircaloy Spacer Grid Assembly for PWR Fuel Assembly(III))

  • 송기남;윤경호;이강희;김수성;한형준
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년도 춘계 학술대회 개요집
    • /
    • pp.42-44
    • /
    • 2006
  • A spacer grid assembly, which is an interconnected array of slotted grid straps and is welded at the intersections to form an egg crate structure, is one of the main structural components of the nuclear fuel assembly for pressurized water reactors(PWRs). The spacer grid assembly is structurally required to have enough buckling strength under various kinds of lateral loads acting on the nuclear fuel assembly so as to keep the nuclear fuel assembly straight. To meet this requirement, it is necessary to weld the welding parts carefully and precisely. In this study, a series of welding tests were carried out to find an optimum welding condition. After examining and analyzing the specimens welded from the welding conditions, a recommendable laser welding condition was selected for the KAERI designed Zircaloy spacer grid assembly.

  • PDF

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

고마하수 유동에서 Roe 해법의 문제와 해결 (Issues and Solutions of Roe Schemes for High Mach Number Flows)

  • 원수희;최정열;정인석
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.128-134
    • /
    • 2005
  • In the CFD area, the numerical analysis of high Mach number flow over a blunt-body poses many issues. Various numerical schemes have been developed to cover the issues, but the traditional schemes are still used widely due to the complexities of new schemes and intricacy of modifying the established codes. In the present study, the well-known Roe's FDS based on TVD-MUSCL scheme is used for the solution of very high Mach number three-dimensional flows posing carbuncle and non-physical phenomena in numerical analysis. A parametric study was carried out to account for the effects of the entropy fixing, grid configurations and initial condition. The carbuncle phenomena could be easily overcome by the entropy fixing, and the non-physical solution could be eliminated by the use of the modified initial condition regardless of entropy fixing and grid configurations.

  • PDF

회전된 엇갈린 격자를 이용한 탄성파 모사에의 CPML 경계조건 적용 (Application of Convolutional Perfectly Matched Layer to Numerical Elastic Modeling Using Rotated Staggered Grid)

  • 조창수
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2008년도 공동학술대회
    • /
    • pp.57-62
    • /
    • 2008
  • 탄성파 수치 모형 계산에 있어서 널리 사용되는 엇갈린 격자 방법이 아니라 회전된 엇갈린 격자 방법을 사용하여 탄성파 수치 모사를 수행하였다. 표준 엇갈린 격자 방법에서는 자유 경계조건을 적용하여야 하는 단점이 있지만 회전된 격자 방법에서는 자유 경계조건을 적용할 필요 없이 물성을 부여함으로써 해결될 수 있다. 파동전파에 있어서 유한 경계 조건에서 발생하는 인공 반사파를 제거하기 위하여 최근에 뛰어난 성능을 보이는 PML(Perfectly Matched Layer)법이 많이 적용되고 있다. 이 연구에서는 PML보다 성능이 뛰어나기도 하지만 차분에 있어 파동식을 분리할 필요가 없는 CPML(Convolutional Perfectly Matched Layer)법을 회전된 엇갈린 격자법(RSG : Rotatged Staggered Grid)에 적용하고자 하였다. Cerjan법의 감쇠법과 비교한 결과 매우 효과적으로 인공 반사파를 제거할 수 있음을 알 수 있었다.

  • PDF

PQ변동을 이용한 개선된 계통 임피던스 추정기법 (An Improved Grid Impedance Estimation using PQ Variations)

  • 조제희;김용욱;김래영
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.152-159
    • /
    • 2015
  • In a weak grid condition, the precise grid impedance estimation is essential to guaranteeing the high performance current control and power transfer for a grid-connected inverter. This study proposes a precise estimation method for grid impedance by PQ variations by employing the variation method of reference currents. The operation principle of grid impedance estimation is fully presented, and the negative impact of the phase locked loop is analyzed. Estimation error by a synchronization angle in the park's transformation using the phase locked loop is derived. As a result, the variation method of reference currents for accurate estimation is introduced. The validation of the proposed method is verified through several simulation results and experiments based on a 2-kW voltage source inverter prototype.

새로운 Zero-Current-Transition 기법을 이용한 계통 연계형 태양광 발전 인버터 시스템 (Grid Connected Photovoltaic Inverter System Using a New Zero-Current- Transition Scheme)

  • 최영덕;이동윤;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.213-215
    • /
    • 2002
  • This paper presents grid connected photovoltaic inverter system using a new Zero-Current-Transition(ZCT) technique. The main switches of the proposed grid connected inverter are turned off under the zero current condition by operating the auxiliary circuit and also all semiconductor devices, switches and diodes, are applied to low rated voltage regardless of the load condition. In additionally, the proposed ZCT scheme has advantages, which are without the additional current stresses and the conduction losses on the main switches during the resonance period of the auxiliary circuit. The simulation was performed to verify the validity of the proposed grid connected photovoltaic ZCT inverter system.

  • PDF

격자 구조물의 비선형 동적 측면 충격해석 (Nonlinear Dynamic Lateral Buckling Behavior of a Grid Structures)

  • 윤경호;송기남;김홍배
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.254-260
    • /
    • 2000
  • The spacer grid is one of the main structural components in fuel assembly, which supports the fuel rods, guides cooling water, and protects the fuel assembly from the external impact load such as earthquakes. The nonlinear dynamic impact analysis is conducted by using the finite element code ABAQUS/Explicit. Boundary condition for dynamic analysis is well applied to the test condition. Simulation results also similarly predict the local buckling phenomena. In addition to the buckling parameter, the local buckling cause is examined by both simulation and test method. It is found to correspond well with the test results. Impact tests are also carried out for some specimens of the spacer grid in order to compare the results between the test and the simulation. This test is accomplished by a free fall dummy weight onto the specimen. From this test, only the uppermost and lowermost layers of the multi-cell are buckled, which implies the local buckling at the weakest point of the grid structure.

  • PDF