• Title/Summary/Keyword: In-band reference wavelength

Search Result 15, Processing Time 0.019 seconds

Design and Fabrication of an NIR Grism Si Optical Area Sensor Spectrometer with In-band Reference Wavelength (대역 내 기준 파장을 갖는 근적외선 그리즘 실리콘 광 면 센서 분광기 설계 및 제작)

  • Song, Jae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.28-34
    • /
    • 2017
  • An NIR grism Si optical area sensor spectrometer with in-band reference wavelength is designed and fabricated. It is composed of a transmission type diffraction grating (spatial density 300 line/mm), a rectangular N-BK7 prism (apex angle 30 degree), NIR filter(cutoff wavelength 720 nm), an imaging convex lens(focal length 50 mm F1.8) and an IR modified DSLR camera (Canon EOS40D) of Si optical area sensor ($3,888{\times}2,592$ pixels, pixel size $5.710{\mu}m$). "In-band reference wavelength function" is implemented using non-dispersive 0th diffraction order optical beam. The NIR grism spectrometer is tested in a laboratory using a halogen lamp and a Neon lamp. And the spectrometer is used in an astronomy field for obtaining the planet Jupiter NIR spectrum. In-band reference wavelength i.e. un-deviation wavelength is 846 nm, an wavelength resolution is 0.3027 nm/pixel, an wavelength resolving power is 2,794 and an wavelength range is 650~1,000 nm.

Wavelength selection by loading vector analysis in determining total protein in human serum using near-infrared spectroscopy and Partial Least Squares Regression

  • Kim, Yoen-Joo;Yoon, Gil-Won
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4102-4102
    • /
    • 2001
  • In multivariate analysis, absorbance spectrum is measured over a band of wavelengths. One does not often pay attention to the size of this wavelength band. However, it is desirable that spectrum is measured at only necessary wavelengths as long as the acceptable accuracy of prediction can be met. In this paper, the method of selecting an optimal band of wavelengths based on the loading vector analysis was proposed and applied for determining total protein in human serum using near-infrared transmission spectroscopy and PLSR. Loading vectors in the full spectrum PLSR were used as reference in selecting wavelengths, but only the first loading vector was used since it explains the spectrum best. Absorbance spectra of sera from 97 outpatients were measured at 1530∼1850 nm with an interval of 2 nm. Total protein concentrations of sera were ranged from 5.1 to 7.7 g/㎗. Spectra were measured by Cary 5E spectrophotometer (Varian, Australia). Serum in the 5 mm-pathlength cuvette was put in the sample beam and air in the reference beam. Full spectrum PLSR was applied to determine total protein from sera. Next, the wavelength region of 1672∼1754 nm was selected based on the first loading vector analysis. Standard Error of Cross Validation (SECV) of full spectrum (1530∼l850 nm) PLSR and selected wavelength PLSR (1672∼1754 nm) was respectively 0.28 and 0.27 g/㎗. The prediction accuracy between the two bands was equal. Wavelength selection based on loading vector in PLSR seemed to be simple and robust in comparison to other methods based on correlation plot, regression vector and genetic algorithm. As a reference of wavelength selection for PLSR, the loading vector has the advantage over the correlation plot since the former is based on multivariate model whereas the latter, on univariate model. Wavelength selection by the first loading vector analysis requires shorter computation time than that by genetic algorithm and needs not smoothing.

  • PDF

Development of Excitation Light Source for Photodynamic Diagnosis of Cancer (광역학적 암진단을 위한 여기 광원장치의 개발)

  • Lim, Hyun-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.49-56
    • /
    • 2007
  • In this paper, the development of excitation light source is proposed for excitation light of the photodynamic therapy of cancer. Since the selection of the wavelength band of excitation light has an interrelation with fluorescence generation according to the selection of a photosensitizer. This study aims at designing and evaluating light source that can stably generate light with various kinds of wavelengths in order to make possible photodynamic diagnosis using a photosensitizer and diagnosis using auto-fluorescence. The light source device was a Xenon lamp and filter wheel, composed of an optical output control through iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source device by KFDA#s technical reference, the characteristics of the light output and wavelength band were found.

Widely tunable thulium-doped fiber laser anchored on 50-GHz ITU-T grid in S/S+ band (S/S+band에서 넓은 파장가변 영역을 가지고 50-GHz ITU-T격자에 맞는 채널을 생성하는 thulium이 첨가된 광섬유 레이저)

  • 안성준;박철근;안승준;박종한;박남규
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.17-21
    • /
    • 2004
  • We demonstrate an S/S+band discretely tunable thulium doped fiber laser (TTDFL), anchored on a 50-㎓ ITU-T grid. Investigating the inversion analysis of the thulium doped fiber (TDF) in applying a dual wavelength (1.4 m and 1.5 m) pumping scheme, a laser whose tuning range covers most of the S/S+band has been obtained. Within the wide 3-㏈ bandwidth of 65.1 nm, the output power of the tunable laser exceeds 6.1 ㏈m with very flat spectral profile and the number of DWDM channels generated is as large as 178. If we increase the subsidiary pump power to 22 ㎽, the bandwidth is expanded up to 66.2 nm. By controlling the temperature of the fine grid filter, we have also shown that the frequency locking capability of the laser can be improved. The laser developed in this work is expected to be utilized as a practical optical source providing reference wavelengths in the S/S+band.

Absorption Spectra of Standard Gases for Wavelength Reference in C-band using a Supercontinuum Source Based on a Mode-locked Cr4+:YAG Laser (모드 잠금 Cr4+:YAG 레이저로부터 발생된 초 광대역 광원을 이용한 광통신 파장 영역의 표준 가스의 흡수스펙트럼)

  • Lee, Jong-Min;Jeon, Min-Yong;Ryu, Han-Young;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.54-59
    • /
    • 2008
  • We report on the measurements of absorption spectra from acetylene ($^{12}C_2H_2$) and hydrogen cyanide ($H^{13}C^{14}N$) for wavelength reference in the C-band (conventional band) region using a supercontinuum optical source generated from a mode-locked $Cr^{4+}$:YAG laser. The center wavelength of the mode-locked $Cr^{4+}$:YAG laser was 1510 nm and the pulse duration was 75 fs at 100 MHz repetition rate. The supercontinuum source achieved a flatness of ${\pm}5dB$ over a wavelength range of more than 400 nm, using a 20 m long photonic crystal fiber. The measured absorption spectra from acetylene ($^{12}C_2H_2$) and hydrogen cyanide ($H^{13}C^{14}N$) had more than 50 lines and were analyzed for wavelength standardization.

A Double-channel Four-band True Color Night Vision System

  • Jiang, Yunfeng;Wu, Dongsheng;Liu, Jie;Tian, Kuo;Wang, Dan
    • Current Optics and Photonics
    • /
    • v.6 no.6
    • /
    • pp.608-618
    • /
    • 2022
  • By analyzing the signal-to-noise ratio (SNR) theory of the conventional true color night vision system, we found that the output image SNR is limited by the wavelength range of the system response λ1 and λ2. Therefore, we built a double-channel four-band true color night vision system to expand the system response to improve the output image SNR. In the meantime, we proposed an image fusion method based on principal component analysis (PCA) and nonsubsampled shearlet transform (NSST) to obtain the true color night vision images. Through experiments, a method based on edge extraction of the targets and spatial dimension decorrelation was proposed to calculate the SNR of the obtained images and we calculated the correlation coefficient (CC) between the edge graphs of obtained and reference images. The results showed that the SNR of the images of four scenes obtained by our system were 125.0%, 145.8%, 86.0% and 51.8% higher, respectively, than that of the conventional tri-band system and CC was also higher, which demonstrated that our system can get true color images with better quality.

Noise Band Extraction of Hyperion Image using Quadtree Structure and Fractal Characteristic (Quadtree 구조 및 프랙탈 특성을 이용한 Hyperion 영상의 노이즈 밴드 추출)

  • Chang, An-Jin;Kim, Yong-Il
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.5
    • /
    • pp.489-495
    • /
    • 2010
  • Hyperspectral imaging obtains information with a wider wavelength range a large number of bands. However, a high correlation between each band, computation cost, and noise causes inaccurate results in cases of no pre-processing. The noises of band extraction and elimination positively necessary in hyperspectral imaging. Since the previous studies have used a characteristic the whole image, a local characteristic of the image is considered for the noise band extraction. In this study, the Quadtree, which is a data structure algorithm. and the fractal dimension are adopted for noise band extraction in Hyperion images. The fractal dimensions of the segments divided by the Quadtree structure are calculated, and variation is used. We focused on the extraction of random noise bands in Hyperion images and compared them with the reference data made by visual decisions. The proposed algorithm extracts the most bands, including random noises. It is possible to eliminate more than 30 noise bands, regardless of images.

Evaluation of the Utility of SSG Algorithm for Image Restoration of Landsat-8 (Landsat 8호 영상 복원을 위한 SSG 기법 활용성 평가)

  • Lee, Mi Hee;Lee, Dalgeun;Yu, Jung Hum;Kim, Jinyoung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_4
    • /
    • pp.1231-1244
    • /
    • 2020
  • Landsat satellites are representative optical satellites that have observed the Earth's surface for a long-term, and are suitable for long-term changes such as disaster preparedness/recovery monitoring, land use change, change detection, and time series monitoring. In this paper, clouds and cloud shadows were detected using QA bands to detect and remove clouds simply and efficiently. Then, the missing area of the experimantal image is restorated through the SSG algorithm, which does not directly refer to the pixel value of the reference image, but performs restoration to the pixel value in the Experimental image. Through this study, we presented the possibility of utilizing the modified SSG algorithm by quantitatively and qualitatively evaluating information on variousl and cover conditions in the thermal wavelength band as well as the visible wavelength band observing the surface.

A Study on the Metal Mesh for CuNx-Cu-CuNx Multi-layer Touch Electrode by Reactive Magnetron Sputtering (Reactive Magnetron Sputtering 적용 CuNx-Cu-CuNx 적층형 Metal Mesh 터치센서 전극 특성 연구)

  • Kim, Hyun-Seok;Yang, Seong-Ju;Noh, Kyeong-Jae;Lee, Seong-Eui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.414-423
    • /
    • 2016
  • In the present study, the $CuN_x-Cu-CuN_x$ layer the partial pressure ratio Cu metal of Ar and $N_2$ gas using a DC magnetron sputtering device, was generated by the In-situ method. $CuN_x$ layer was able to obtain a surface reflectance reduction effect from the advantages of the process and the external light. $CuN_x$ layer is gas partial pressure, DC the Power, the deposition time variable transmittance in response to the thickness and partial pressure ratio, the reflectance was measured. $Ar:N_2$ gas ratio 10:10(sccm), DC power 0.35 A, was derived Deposition time 90 sec optimum conditions. Thus, according to the optimal thickness and the composition ratio was derived surface reflectance of 20.75%. In addition, to derive the value of ${\Delta}$ Ra surface roughness of 0.467. It was derived $CuN_x$ band-gap energy of about 2.2 eV. Thus, to ensure a thickness and process conditions can be absorbed to maximize the light in a wavelength band in the visible light region. As a result, the implementation of the $12k{\Omega}$ base line resistance of using the Cu metal. This is, 5 inch Metal mesh TSP(L/S: $4/270{\mu}m$) is in the range of the reference operation.