• Title/Summary/Keyword: In-Process Profile Measurement

Search Result 113, Processing Time 0.03 seconds

Development for Automatic Thickness Measurment System by Digital Image Processing (디지탈 이미지 프로세싱을 이용한 자동두께 측정장치 개발)

  • 김영일;이상길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.395-401
    • /
    • 1993
  • The purpose of this paper is to develop an automatic measuring system based on the digital image processing which can be applied to the in-process measurement of the characteristics of the thin thickness. The derivative operators is used for edge detection in gray level image. This concept can be easiliy illustrated with the aid of object shows an image of a simple light object on a dark background, the gray level profile along a horizontal scan line of the image, and the first and second derivatives of the profile. The first derivative of an edge modeled in this manner is () in all regions of constant gray level, and assumes a constant value during a gray level transition. The experimental results indicate that the developed qutomatic inspection system can be applied in real situation.

  • PDF

Measurement of Water Flow in Closed Conduits by Chemical Tracer Method (추적자를 이용한 유량 측정)

  • Lee, Sun-Ki;Chung, Bag-Soon;Kim, Chang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.2 s.3
    • /
    • pp.19-26
    • /
    • 1999
  • Thermal output in a nuclear power plant is verified with calorimetric heat balance on the secondary plant. The calorimetry involves the precise measurement of the feedwater flow rate. However, the correct indication of feedwater flow rate obtained by a pressure-difference measurement across a venturi can be affected by instrument errors, fouling or a poorly developed velocity profile. This can result in an inaccurate mass flow rate and consequently an inaccurate estimate of power. The purpose of this study is to develop verification methods with accuracy better than $0.5\%$ for high precision flow measurement to be used for measuring feedwater flow rate. This chemical tracer method is a testing process that uses tracers which can be applied to quantify losses in electrical output due to the incorrect measurements of feedwater flow rate. And this system has good response to the variation of the flow rate. Accuracy of better than 0.5 percent can be expected for feedwater flow measurement, providing that the system can be stabilized during the test. This methodology is applicable to other flow systems well.

  • PDF

Truing Performance of Metal-Bonded Grinding Wheel by Electro-Discharge Truing Method (금속결합제 연삭숫돌의 방전트루잉 성능 평가)

  • Kim, Tae-Kyu;Shin, Gun-Hwi;Jung, Myung-Won;Kwak, Tae-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.3
    • /
    • pp.79-85
    • /
    • 2016
  • Truing process is a very important process for recovering the shape of wheels worn by continuous grinding operation. In this study, the devices, controller, and spindle for electro-discharge truing were developed, and the electro-discharge truing method was applied to metal-bonded grinding wheels and compared with the conventional truing method. The shapes of the grinding wheels were measured by a surface profile measurement device. The protrusion of abrasives on the surface of the wheels was compared with the conventional truing method using an optic microscope measurement device. The experimental results showed that the performance of the electro-discharge truing method, in terms of the protrusion of abrasives on the surface of the wheels and the recovery of the shape of the worn wheels, was similar to that of the conventional truing method.

Development of Pulse Diagnosis Hold-down Pressure Measurement System (맥진 가압 프로파일 측정 시스템 개발)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Ryu, Hyun-Hee;Woo, Young-Jae;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1997-1998
    • /
    • 2008
  • Pulse diagnosis is the one of the most important diagnostic process to traditional medical doctors. Although the pulse diagnosis position, Gwan is apart from Chon or Cheok by 10$\sim$20mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Chon, Gwan and Cheok. One the other hand, the education on pulse diagnosis behavior includes tantalizing problem caused by no tool for communication between trainer and trainee. On account of this situation, we tried to develop a system which can measure the hold-down pressure during a pulse diagnosis and compare the hold-down pressure profile of trainer and that of trainee. This system can be divided into three parts - pulse pressure sensing part, signal acquisition part and data storing part. A correction curve was generated by the relation between output voltages and standard weights. Using this system, 3 channel hold-down pressure profile of a oriental medical doctor were recorded three times. In the profile, three period were observed and all period included two process for searching the depth of pulsation and for classifying the pulse feeling into one or more of 28 pulse types. The maximum value of pulse profile was 1.3$kg{\cdot}f$ which was more than reported by previous chinese groups and the mean values of three channel ranged from 240$g{\cdot}f$ to 430$g{\cdot}f$. In frequency domain, each channel has some dominant frequency components - about 10Hz, 35Hz and 75Hz. In further study, we want to collect more profiles from lage number of oriental medicine doctors and hope to develop a measuring system which can measure the hold-down pressure on subject's skin directly.

  • PDF

Development parameter measurement and profile analysis of electron beam resist for lithography simulation (리소그라피 모의실험을 위한 전자빔용 감광막의 현상 변수 측정과 프로파일 분석)

  • 함영묵;이창범;서태원;전국진;조광섭
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.198-204
    • /
    • 1996
  • Electron beam lithography is one of the importnat technologies which can delineate deep submicron patterns. REcently, electron beam lithography is being applied in delineating the critical layers of semiconductor device fabrication. In this paper, we present a development simulation program for electron beam lithography and study the development profiles of resist when resist is exposed by the electron beam. Experimentally, the development parameter of positive and negative resists are measured and the data is applied to input parameter of the simulation program. Also simulation results are compared of the process results in the view of resist profiles. As a result, for PMMA and SAL 601 resist, the trend of simulation to the values of process parameters agree with real process results very well, so that the process results can be predicted by the simulation.

  • PDF

A Study on Mission Profile and Determination of Durability Test Parameters in the Hydraulic Clutch System (Hydraulic Clutch System의 Mission Profile 및 내구시험모수 결정에 관한 연구)

  • Lee, Sang-Cheon;Hur, Man-Dae;Lee, Chun-Gon;Kim, Jae-Young;Kang, Ji-Woo;Lee, Hong-Bum;So, Yoon-Sub;Lee, Jong-Hyung;Min, Byung-Gil;Lee, Jae-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.5
    • /
    • pp.521-528
    • /
    • 2009
  • One of reliability measurements of vehicle is estimated by driving mileage but the reliability of component, such as an hydraulic clutch system, is defined from the number of successful operational cycle. Relationship between these reliability measurement variables(mileage and cycle) should be examined first of all in the reliability estimation of components. Relationship between mileage and cycles is commonly known as linear function. However, the gradient depends on the operational environmental condition. Therefore, estimation of mission profile variable should be done with correlation analysis at the same time. In this paper, we derive mission profile variable of an hydraulic clutch system by field vehicle test and suggest the determination process of durability test parameters of CMC(Clutch Master Cylinder) with mission profile variable.

A Study on the Tower type Fizeau Interferometer System with a Fold Minor for Measuring Large Optical Lens Profile (반사경 측정을 위한 타워 방식의 Fold Mirror를 이용한 Fizeau 간섭계 시스템 구성)

  • Lee, Eung-Suk;Lee, Ki-Am;Kim, Ok-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.21-28
    • /
    • 2008
  • Fizeau interferometer is used for inspecting the lens surface profile accurately. This study is focused on the design and optical measuring techniques for large optical components, such as a reflection mirror for large area lithography or astronomical purpose. A tower type Fizeau interferometer is designed and set up in horizontally with a 45$^{\circ}$ fold mirror which makes easy to align the optical path of heavy interferometer system. To align the optical path, a five-axes stage for the interferometer is required. This study shows a method of the 45$^{\circ}$ fold mirror alignment by using a three-axis stage instead of adjusting the interferometer itself or measuring object. This system will be installed on the large optics polishing machine during the manufacturing process as an on-machine inspection system.

The formation of Paper and the Measurement of Formation

  • Komppa, Olavi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.29 no.2
    • /
    • pp.76-82
    • /
    • 1997
  • In paper the evenness of planar distribution of mass in a small scale is called formation (orbetter:mass formation). Traditionally formation has been assessed visually, by looking the sheet of paper against transmitted light. Different kinds of optieal testers are being usd to obtain quantitative rankings htat would be independent of the observer but would well correspond to the visual assessment. However, various raw-material and process factors do influence light trans-mittance in paper and do impair the correspondence between basis weight and the optical formation measurement (or visual assessment). As the optical formation test methods do not incorporate an efficient calib ration routine, the formation of the sophisticated paper grades of today the is rather difficult to measure optically and may lead to erroneous results. It may be concluded that the optical measurement is not suitable for paper grades with high filler content. coating, heavy calendering or that are made of heavily beaten pulp, nordoes it apply for dyed or printed papers. For this reason, visual assessment and optical evaluation shoild be replaced with a measurement that gives reliable results independent on paper grode and manufacturing process. Formation measuremend based on beta radiation is suitable for all paper grades regardless to the material contents or process treatment. It is possible to measure even dyed or printed samples. Thonks to a sim ple and relioble calibration, the results are converted to real basis weight balues that remain reliable even with time. The only beta tester commercially available is the AMBERTEC Beta Formation Tester. Formation of paper does vary locally in the web. Typically there exists a formation profile, too similarly to other properties of paper. Therefore, formation should ? ays be expressed as a mean of a sufficient amount of parallel determinations. All formation measurements should be calibrated against basis weight.

  • PDF

A Study on Enhancement of Grinding Accuracy by an Active Tool Control

  • Oh, Chang-Jin;Kim, Ock-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.633-638
    • /
    • 2002
  • An approach to enhance dimensional accuracy of the grinding process has been presented, and grinding of a glass material with a metal-bonded diamond wheel has been studied. In this study, a grinding tool is suspended flexibly and controlled by an electromagnetic actuator. During grinding, profile error of a ground surface is indirectly measured and fed back to a control system. A model of grinding error has been suggested on which the indirect measurement has been based. An optimal PID control is adopted and effectiveness of the in-process feedback control has been verified experimentally.

Errors in Net Ecosystem Exchanges of CO2, Water Vapor, and Heat Caused by Storage Fluxes Calculated by Single-level Scalar Measurements Over a Rice Paddy (단일 높이에서 관측된 저장 플럭스를 사용할 때 발생하는 논의 이산화탄소, 수증기, 현열의 순생태계교환량 오차)

  • Moon, Minkyu;Kang, Minseok;Thakuri, Bindu Malla;Lee, Jung-Hoon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.3
    • /
    • pp.227-235
    • /
    • 2015
  • Using eddy covariance method, net ecosystem exchange (NEE) of $CO_2$ ($F_{CO_2}$), $H_2O$ (LE), and sensible heat (H) can be approximated as the sum of eddy flux ($F_c$) and storage flux term ($F_s$). Depending on strength and distribution of sink/source of scalars and magnitude of vertical turbulence mixing, the rates of changes in scalars are different with height. In order to calculate $F_s$ accurately, the differences should be considered using scalar profile measurement. However, most of flux sites for agricultural lands in Asia do not operate profile system and estimate $F_s$ using single-level scalars from eddy covariance system under the assumption that the rates of changes in scalars are constant regardless of the height. In this study, we measured $F_c$ and $F_s$ of $CO_2$, $H_2O$, and air temperature ($T_a$) using eddy covariance and profile system (i.e., the multi-level measurement system in scalars from eddy covariance measurement height to the land surface) at the Chengmicheon farmland site in Korea (CFK) in order to quantify the differences between $F_s$ calculated by single-level measurements ($F_s_{-single}$ i.e., $F_s$ from scalars measured by profile system only at eddy covariance system measurement height) and $F_s$ calculated by profile measurements and verify the errors of NEE caused by $F_s_{-single}$. The rate of change in $CO_2$, $H_2O$, and Ta were varied with height depending on the magnitudes and distribution of sink and source and the stability in the atmospheric boundary layer. Thus, $F_s_{-single}$ underestimated or overestimated $F_s$ (especially 21% underestimation in $F_s$ of $CO_2$ around sunrise and sunset (0430-0800 h and 1630-2000 h)). For $F_{CO_2}$, the errors in $F_s_{-single}$ generated 3% and 2% underestimation of $F_{CO_2}$ during nighttime (2030-0400 h) and around sunrise and sunset, respectively. In the process of nighttime correction and partitioning of $F_{CO_2}$, these differences would cause an underestimation in carbon balance at the rice paddy. In contrast, there were little differences at the errors in LE and H caused by the error in $F_s_{-single}$, irrespective of time.