• 제목/요약/키워드: In-Phase

검색결과 42,027건 처리시간 0.059초

국제기술협력 관계 프로세스 모형 개발에 관한 연구 (Research on International Technical Cooperation Relationship Process Model)

  • 김진숙
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.4796-4800
    • /
    • 2011
  • 본 논문에서는 국제기술협력 관계 프로세스 모형이 개발되었다. 모델은 5단계로 구성되어있다: 시작단계 파트너 탐색단계, 계약단계, 실행단계 그리고 종료단계. 시작단계에서 산업체들은 자신이 필요한 것을 잘 인지하지 못하는 경향이 있었으며 파트너 탐색단계에서는 자신에게 필요한 파트너 탐색에 어려움을 가지고 있었다. 계약단계에서는 국제법에 대한 어려움과 실행단계에서는 문화적 어려움을 가지고 있었다. 따라서 정부는 각 단계별 지원책을 모색할 필요가 있다.

New Control Strategy for Reducing Switching Losses in Three-Phase Voltage-Source PWM Converters

  • Dong, Xiaopeng;Wang, Zhaoan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.366-373
    • /
    • 1998
  • In this paper, a new control strategy to reduce switching losses in three-phase voltage-source PWM converters is proposed according to Modified-Period-Average-Model (MPAN). The basic concept of this strategy is aimed at calculating the phase control voltages for controlling the source currents to be sinusoidal and in phase with the source voltages, and reducing the number of switching in each period. The phase control voltages of Period-Average-Model(PAM) is obtained according to analyzing the operation of PWM converter. In order to reduce the sensitivity to system parameters in PAM, MPAM is deduced. Then a square wave whose frequency is three times of utility frequency is added to the phase control voltages derived from MPAM. The control strategy reduces the switching losses since there exists about one-third blanking time for every phase in one period. The theoretical derivation and the control strategy are experimentally verified on a 2.5 kW three-phase voltage source converter.

  • PDF

3상 3레벨 인버터의 중성점 제어를 이용한 고조파 왜율 저감 효과 (The effect of Harmonic Distortion Reduction on Three Phase Three level Inverter Using Neutral Point Control)

  • 김정규;양오
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.90-94
    • /
    • 2018
  • In this paper, we applied a three-level T-type inverter with the one more voltage level than two-level inverter. However, the three-level T-type inverter has a systematic problem with voltage unbalances. So neutral point control is essential. Therefore, the voltage unbalance problem of the three - phase inverter was confirmed to be controlled within 5V using the neutral point control algorithm in charge and discharge mode. In addition, total harmonic distortion was reduced in three phases (u phase, v phase, w phase) when neutral point control was performed in charging mode and also in three phases (u phase, v phase, w phase) in discharge mode. In this paper suggests a neutral point control algorithm to solve the voltage unbalance of a three-level T-type inverter, and shows the improvement of the performance of the proposed algorithm through experiment.

단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석 (Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer)

  • 김종겸;김지명
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

정방정상과 능면체상의 경계조성 Pb(Zr, Ti)$O_3$ 세라믹스에서 화학조성의 불균일성이 상공존에 미치는 영향 (Effects of Chemical Inhomogeneity on Phase Coexistence in Pb(Zr, Ti))$O_3$ Ceramics at Morphotropic Tetragonal and Rhombohedral Phase Boundary)

  • 천채일;김호기
    • 한국세라믹학회지
    • /
    • 제27권8호
    • /
    • pp.1027-1033
    • /
    • 1990
  • In order to identify the origin of phase coexistence at morphotropic tetragonal and rhombohedral boundary in PZT ceramics, the effect of chemical inhomogeneity on phase coexistence region was investigated. Two kinds of PZT ceramics with different chemical homogeneity were prepared by conventional solid state reaction and co-precipitation method. There was coexistence of tetragonal and rhombohedral phase over a wide composition range in PZT ceramics calcined by solid state reaction, and there was also phase coexistence of which region was reduced considerably in sintered samples. And phase coexistence region was not observed in co-precipitated PZT ceramics(within 1 mole%). Therefore compositional fluctuation is considered to be major origin of the phase coexistence at morphotropic phae boundary in PZT ceramics.

  • PDF

Modified Direct Torque Control System of Five Phase Induction Motor

  • Kim, Nam-Hun;Kim, Min-Huei
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.266-271
    • /
    • 2009
  • In this paper, improved direct torque control(DTC) of five-phase induction motor(IM) is proposed. Due to the additional degrees of freedom, five-phase IM drives present unique characteristics. One of them is the ability of enhancing the torque producing capability of the motor. Also five-phase motor drives possess many others advantage compared with the traditional three-phase motor drives. Such as, reducing the amplitude and increasing of frequency of torque pulsation, reducing amplitude of current per phase without increasing the voltage per phase and increasing the reliability. The direct torque control method is advantageous when it is applied to the five-phase IM. Because the five-phase inverter provides 32 space vectors in comparison to 8 space voltage vectors by the three-phase inverter. The 32 space voltage vectors are divided into three groups according to their magnitudes. The characteristics and dynamic performance of traditional five-phase DTC are analyzed and new DTC for five-phase IM is proposed. Therefore, a more precise flux and torque control algorithm for the five-phase IM drives can be suggested and explained. For presenting the superior performance of the pro-posed direct torque control, experimental results is presented using a 32 bit fixed point TMS320F2812 digital signal processor

25Cr-7Ni-2Mo-4W 슈퍼 2상 스테인리스강의 기계적 성질에 미치는 R상의 영향 (Effect of R Phase Formation on the Mechanical Properties of 25Cr-7Ni-2Mo-4W Super Duplex Stainless Steel)

  • 이병찬;강창룡
    • 한국재료학회지
    • /
    • 제24권8호
    • /
    • pp.401-406
    • /
    • 2014
  • In this study, we investigated the precipitation behavior of the R-phase precipitated at the initial stage of aging and its effects on the mechanical properties of 25%Cr-7%Ni-2%Mo-4%W super duplex stainless steel. The R-phase was mainly precipitated at the interface of ferrite/austenite phases and inside of the ferrite phase during the initial stage of aging. It was transformed into the ${\sigma}$-phase with an increase of the aging time. The ferrite phase was decomposed into a new austenite(${\gamma}_2$)phase and the ${\sigma}$-phase by an aging treatment. The R phase was an intermetallic compound showing higher molybdenum and tungsten concentrations than the matrix and also showed higher molybdenum and tungsten concentrations than the ${\sigma}$ phase. In the initial stage of aging, precipitation of the R-phase did not change the hardness, the strength and the elongation. The hardness and the strength increased upon a longer aging time, but the elongation rapidly decreased. These results show that the R-phase did not significantly affect the hardness and the strength, though it did influence the elongation.

Cochlodinium polykrikoides(Dinophyceae)에서 분비되는 유기물질의 특성 (Characteristics of Organic Substances Produced from Cochlodiniumpolykrikoides (Dinophyceae))

  • 강양순;권정노;안경호
    • ALGAE
    • /
    • 제21권2호
    • /
    • pp.253-259
    • /
    • 2006
  • Organic substances are released from phytoplankton cells during all phases of growth. The type and amounts of organic substance excreted and the effects of nutrient limitation are often highly species-specific. Dinoflagellate, Cochlodinium polykrikoides grown in batch culture produced an exopolysaccharide. Exopolysaccharide and intracellular polysaccharide concentrations increased as C. polykrikoides cultures progressed from exponential phase, through stationary phase, to declining phase. In the exponential phase, the concentration of exopolysaccharide was relatively low, but in the stationary phase, it showed a rapid increase which seemed to coincide with the depletion of nitrate from the medium. Of the 20 amino acids analyzed, proline dominated in the organic matter of all cultures ranging from 48.2 to 79.9 nmol L–1, and constituting the 20-90% of total amino acids, and followed by histamine varying from 0.7 to 47.5 nmol L–1. Leucine and cysteine were also abundant in the stationary phase. The release rates of exopolysaccharide and intracellualr polysaccharide were higher the end of stationary phase than in the exponential phase. Exopolysaccharide concentration per cell was more than two times higher during the end of stationary phase than that in exponential phase. C. polykrikoides produced extracellular polysaccharide at a rate of 47.04 pg cell–1 day–1.

A novel PLL control method for robust three-phase thyristor converter under sag and notch conditions

  • Lee, Changhee;Yoo, Hyoyol
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.87-88
    • /
    • 2014
  • The paper presents a novel phase locked loop(PLL) control method for robust three-phase thyristor dual converters under sag, notch, and phase loss conditions. This method is applied to three line to line voltages of grid to derive three phase angle errors from three separated single-phase PLLs. They can substitute for abnormal phase to guarantee the synchronization in the various grid fault conditions. The performance of novel PLL with moving average method is verified through simulations.

  • PDF

Thyristor를 이용한 Phase shift에 관한 연구 (A Study on the Phase Shift With the Thyrtisors Utilized)

  • 박민호;김민수
    • 전기의세계
    • /
    • 제27권6호
    • /
    • pp.63-68
    • /
    • 1978
  • To convert into multiphase from single phase are often necessary for industry field. In oder to convert of phase, phase shifted voltages are first buileded by single phase and then must combine with these voltages adequately. This paper aims at the description of the way of phase shift by means of turning on or turning off through natural commutation and forced commutation methods with firing angle of thyristor pating a role of switching controlled adequately. Experimental result of the Phase Shift with the Thyristors Utilized has been turned out to shift the phase to 60.deg., 90.deg., 120.deg., and other angles.

  • PDF