• 제목/요약/키워드: In situ measurement

검색결과 610건 처리시간 0.04초

Application of In Situ Measurement for Site Remediation and Final Status Survey of Decommissioning KRR Site

  • Hong, Sang Bum;Nam, Jong Soo;Choi, Yong Suk;Seo, Bum Kyoung;Moon, Jei Kwon
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.173-178
    • /
    • 2016
  • Background: In situ gamma spectrometry has been used to measure environmental radiation, assumptions are usually made about the depth distribution of the radionuclides of interest in the soil. The main limitation of in situ gamma spectrometry lies in determining the depth distribution of radionuclides. The objective of this study is to develop a method for subsurface characterization by in situ measurement. Materials and Methods: The peak to valley method based on the ratio of counting rate between the photoelectric peak and Compton region was applied to identify the depth distribution. The peak to valley method could be applied to establish the relation between the spectrally derived coefficients (Q) with relaxation mass per unit area (${\beta}$) for various depth distribution in soil. The in situ measurement results were verified by MCNP simulation and calculated correlation equation. In order to compare the depth distributions and contamination levels in decommissioning KRR site, in situ measurement and sampling results were compared. Results and Discussion: The in situ measurement results and MCNP simulation results show a good correlation for laboratory measurement. The simulation relationship between Q and source burial for the source layers have exponential relationship for a variety depth distributions. We applied the peak to valley method to contaminated decommissioning KRR site to determine a depth distribution and initial activity without sampling. The observed results has a good correlation, relative error between in situ measurement with sampling result is around 7% for depth distribution and 4% for initial activity. Conclusion: In this study, the vertical activity distribution and initial activity of $^{137}Cs$ could be identifying directly through in situ measurement. Therefore, the peak to valley method demonstrated good potential for assessment of the residual radioactivity for site remediation in decommissioning and contaminated site.

심부 급경사 연약층의 채굴 진행에 따른 주변 암반 거동의 탄소성 해석 및 현장계측 (Elasto-plastic Analysis and In-situ Measurement on Rock Behaviors with Stepwise Excavation of the Steep Soft Seam at a Great Depth)

  • 정소걸;신중호
    • 터널과지하공간
    • /
    • 제14권4호
    • /
    • pp.295-303
    • /
    • 2004
  • 연약층과 견고한 암반층이 습곡형태로 혼재된 지질조건의 지하 심부 채굴 현장을 대상으로, 심부 급경사 연약층의 단계적 굴착 진행에 따른 갱도 및 주변 암반의 거동 양상을 전산해석과 현장계측을 통하여 비교 분석하였다. 전산해석에서는 Hoek & Brown의 경험적 파괴기준 및 변형률연화모델을 적용한 탄소성 해석 기법을 이용하였다. 현장계측에서는 유압캡슐, 지중변위계, 내공변위계를 갱도 및 주변 암반에 설치하여 응력과 변위를 계측하였다. 경험적 파괴조건 및 변형률연화모델을 이용한 탄소성 해석은, 현장 지질조건 및 채굴과정의 복잡함에도 불구하고 현장계측결과와 유사한 양상을 보여주어 타당성을 검증할 수 있었다. 이러한 전산해석 및 현장계측의 비교를 통해 지하 굴착 갱도의 변형 거동 과정을 예측하고 이후의 굴착 및 지보보강 설계의 지침을 제공할 수 있을 것이다.

콘서트홀의 Sound Strength 현장 측정법 고찰 (Investigation of an in-situ measurement method for Sound Strength in concert halls)

  • 정충일;유진;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.987-990
    • /
    • 2007
  • The accuracy of sound strength (G) measurement method in ISO 3382 has been questioned. One of the main reason is the difficulty in measuring a reference sound level in an anechoic chamber with the same set-up which was applied for the actual hall measurements. In the present paper, an in-situ measurement method for G was proposed by investigating the present G measurement method shown in ISO 3382. In addition, the sound radiation characteristics of typical omnidirectional loudspeakers were investigated and Phi (O) of auto correlation function (ACF) parameters was also calculated from an actual music excerpt to characterize the sound energy distribution in concert halls.

  • PDF

미세부품 영상 측정시 진동에 의한 오차 보상 알고리즘 개발 (Development of Error Compensation Algorithm for Image based Measurement System)

  • 표창률
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.102-108
    • /
    • 2004
  • In this paper, we studied a vibration problem that is critical and common to most precision measurement systems. For micro mechanical part measurements, results obtained from the vision-based precision measurement system may contain errors due to the vibration. In order to defeat this generic problem, for the current study, a PC based image processing technique was used first, to assess the effect of the vibration to the precision measurement and second, to develop an in-situ calibration algorithm that automatically compensate the measurement results in real time. We used a set of stereoscopic CCD cameras to acquire the images for the dimensional measurement and the reference measurement. The mapping function was obtained through the in-situ calibration to compensate the measurement results and the statistical analysis for the actual results is provided in the paper. Based on the current statistical study, it is expected to obtain high precision results for the micro measurement systems.

In-Situ 측정법을 이용한 고리 원자로 방사선원항 평가 (Assessment of the Radiological Inventory for the Reactor at Kori NPP Using In-Situ Measurement Technology)

  • 정현철;정성엽
    • 방사성폐기물학회지
    • /
    • 제12권2호
    • /
    • pp.171-178
    • /
    • 2014
  • 원전 해체 시 원자력설비는 안전하게 해체되어야 한다. 고리 1호기나 월성 1호기와 같은 노후화된 원전의 경우 곧 원전 해체를 계획하고 있는 대상 원전이지만, 이 원전들의 가동 중단 후 해체 시 선원항 평가 기준, 제염 및 해체 기술 등의 독자적인 국내 기술 확보는 미흡한 실정이다. 본 연구의 목적은 원전 선원항 평가 기술 중 하나로 In-Situ 기법을 이용하여 대형 원전 기기를 직접 측정하여 측정대상체에 대한 선원항 평가방법을 개발하는 것이다. 원자로 헤드를 별도의 해체 없이 이동형 감마핵종분석기를 이용하여 직접 측정법으로 분석하고 간접 측정을 병행하여 측정 결과를 보완하였다. 그리고, 표면오염시료는 방사화학분석을 수행하였다. 분석 결과를 확장하여 원자로의 핵종 재고량을 계산하였다. 본 연구 결과를 토대로 각 핵종별 방사능량 변화에 따라 해체 시점을 결정할 수 있으며, 원전 해체 시 작업자의 피폭 저감에 도움이 될 것으로 기대한다.

In-situ fatigue monitoring procedure using nonlinear ultrasonic surface waves considering the nonlinear effects in the measurement system

  • Dib, Gerges;Roy, Surajit;Ramuhalli, Pradeep;Chai, Jangbom
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.867-876
    • /
    • 2019
  • Second harmonic generation using nonlinear ultrasonic waves have been shown to be an early indicator of possible fatigue damage in nuclear power plant components. This technique relies on measuring amplitudes, making it highly susceptible to variations in transducer coupling and instrumentation. This paper proposes an experimental procedure for in-situ surface wave nonlinear ultrasound measurements on specimen with permanently mounted transducers under high cycle fatigue loading without interrupting the experiment. It allows continuous monitoring and minimizes variation due to transducer coupling. Moreover, relations describing the effects of the measurement system nonlinearity including the effects of the material transfer function on the measured nonlinearity parameter are derived. An in-situ high cycle fatigue test was conducted using two 304 stainless steel specimens with two different excitation frequencies. A comprehensive analysis of the nonlinear sources, which result in variations in the measured nonlinearity parameters, was performed and the effects of the system nonlinearities are explained and identified. In both specimens, monotonic trend was observed in nonlinear parameter when the value of fundamental amplitude was not changing.