• Title/Summary/Keyword: In phase mode

Search Result 2,007, Processing Time 0.031 seconds

An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition (계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어)

  • Tae-Hyeon Park;Hag-Wone Kim;Kwan-Yuhl Cho;Joon-Ki Min;Won-Il Choi
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

A Single-Phase Quasi Z-Source AC-AC Converter with a Series Connection of the Output Terminals (출력이 직렬 결합된 단상 Quasi Z-소스 AC-AC 컨버터)

  • Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.415-429
    • /
    • 2011
  • In this study, a single-phase quasi Z-source AC-AC converters with a series connection of the output terminals is proposed. The proposed system has configuration that the input terminals of two quasi Z-source AC-AC converters are connected in parallel and its output terminals are connected in series. The out of phase mode and in phase mode of the proposed system are presented. To verify the validity of the proposed converter, a DSP controlled hardware was made and PSIM simulation was executed. As a result, controlling the duty ratio of the converter, the desired buck-boost output voltages could be generated. For each modes, as compared with the single converter operation, the proposed converter could enhance the efficiency and input power factor according to different loads. Also, in case of the out of phase mode under the constant load, the efficiency and input power factor of the proposed system are increased 10[%], 35[%] respectively in compared with the single converter. And, the output voltage is constantly controlled in dynamic state in case while the load is suddenly changed.

Non-data Aided Timing Phase Recovery Scheme for Digital Equalization of Chromatic Dispersion and Polarization Mode Dispersion

  • Park, Jang-Woo;Chung, Won-Zoo;Park, Jong-Sun;Kim, Sung-Chul
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.367-372
    • /
    • 2009
  • In this paper we propose an electronic domain timing phase selection scheme for the optical communication systems suffering from inter-symbol-interference (ISI) distortion due to chromatic dispersion (CD) or polarization mode dispersion (PMD). In the presence of CD/PMD a proper timing phase selection is important for discrete time domain equalizers, since different timing phases produce different nonlinear ISI channels of different severity. The proposed timing phase recovery scheme based on dispersion minimization (DM) practically approximates the optimal minimum mean squared error (MMSE) timing phase without training signals which reduces overall throughput substantially, especially in time-varying channels such as PMD. The simulation results show that the proposed DM timing agrees with MMSE timing phase, under proper normalization of the received signals, for various dispersion and OSNR.

Phase diagrams adn stable structures of stranski-krastanov structure mode for III-V ternary quantum dots

  • Nakajima, Kazuo;Ujihara, Toru;Miyashita, Satoru;Sazaki, Gen
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.4
    • /
    • pp.387-395
    • /
    • 1999
  • The strain, surface and interfacial energies of III-V ternary systems were calculated for three kinds of structure modes: the Frank-van der Merwe(FM) mode, the Stanski-Krastanov(SK) mode and the Volmer-Weber(VW) mode. The free energy for each mode was estimated as functions of thickness and composition or lattice misfit. Through comparison of the free energy of each mode, it was found that the thickness-composition phase diagrams of III-V ternary systems can be determined only by considering the balance of the free energy and three kinds of structure modes appear in the phase diagrams. The SK mode appears only when the lattice misfit is large and/or the lattice layer is thick. The most stable structure of the SK mode is a cluster with four lattice layers or minimum thickness on a wetting layer of increasing lattice layers. The VW mode appears when the lattice misfit is large and the lattice layer is thin and only in the INPSb/InP and GaPSb/GaP system which have the largest lattice misfit of III-V ternary systems. The stable region of the SK mode in the GaPSb/GaP and InPSb/InP phase diagrams is largest of all because the composition dependence of the strain energy of these systems is stronger than that of the other systems. The critical number of lattice layers below which two-dimensional(2D) layers precede the three-dimensional(3D) nucleation in the SK mode at x=1.0 depends on the lattice misfit.

  • PDF

A Study of the comparison of Inversion of Rayleigh wave Group and Phase Velocities for Regional Near-Surface 2-Dimensional Velocity Structure (천부지각 2차원 속도구조를 위한 레일리파의 군속도와 위상속도 역산의 비교 연구)

  • Lee, Bo-Ra;Jung, Hee-Ok
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.51-59
    • /
    • 2006
  • The surface wave data obtained in a tidal flat located in the sw coast of the Korean Peninsula were used to analyse the shear wave velocity structure of the area. First, the phase velocity dispersion curves were obtained by the tau-p stacking method and the group velocity dispersion curves by a wavelet transform method and the Multiple Filtering Technique by Dziewonski. The phase velocity dispersion curves exhibited bigger errors than the group velocity curves. The results showed that the wavelet transform method was more effective in separating the fundamental and the 1st higher mode group velocity curves than the Multiple Filtering Technique. Combined use of the fundamental and the 1st higher mode group velocity dispersion curves in the inversion for the shear wave velocity structure gave better spatial resolution compared when the fundamental mode group velocity was used alone. This study indicates that the group velocity dispersion curves can be used in the inversion of Rayleigh waves for the shear wave velocity structure, especially effectively with the higher mode group velocity curves together.

  • PDF

Average Current Mode Control Technique Having Fast Response (빠른 응답 특성을 가지는 Average Current Mode Control 설계 기법 연구)

  • Park, Hae-Chan;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.231-239
    • /
    • 2017
  • A novel current control technique with fast response and application in an unbalanced system is proposed in this paper. Contrary to the conventional PI and dead-beat current control techniques, the proposed method is adopted to the valley current mode control (VCMC) and average current mode control (ACMC) methods to overcome the phase delay caused by conventional methods. The advantages of the proposed system are simplicity of structure and ease of implementation. The VCMC and ACMC methods are established and applied to the buck converter, boost converter, three-phase PWM converter, and three-phase inverter. The control performances of the proposed systems are shown by computer simulations and verified by experimental results.

Analytical Study on the Free Vibration of Two Rectangular Plates Coupled with Fluid (유체로 연성된 두 직사각 평판의 고유진동에 관한 해석적 연구)

  • 유계형;정경훈;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.647-651
    • /
    • 2002
  • This study dealt with the free vibration of two identical rectangular plates coupled with fluid. In order to investigate the vibration characteristics of fluid-coupled rectangular plates, an analytical method based on the finite Fourier series expansion and Rayleigh-Ritz method was suggested. A commercial computer code, ANSYS was used to perform finite element analysis and we investigated the vibration characteristics with mode shapes and natural frequencies. As a result, the transverse vibration modes, in-phase and out-of-phase, were observed alternately in the fluid-coupled system. The effect of fluid bounding and plate boundary condition on the fluid-coupled natural frequency were investigated. It was shown that the mode numbers increased, the normalized natural frequencies monotonically increased.

  • PDF

A Study on a New Carrier Recovery Algorithm for Coherent Burst-mode Communication Systems (동기식 버스트 통신시스템 적용을 위한 새로운 반송파 동기 기법에 관한 연구)

  • Park, Sung-Bok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1043-1048
    • /
    • 2011
  • In this paper, a newsynchronization technique applied to burst-mode communication is proposed. A synchronization technique is to estimate carrier frequency and phase offsets in a noisy channel environment. A fundamental problem for estimating the parameters(carrier phase and frequency offsets) in burst-mode transmission is that the ways of pursuing estimation accuracy and transmission efficiency are always trade-off. To solve this problem, a new carrier recovery technique is proposed to improve the transmission efficiency with reliable performance especially at low S/N. In the proposed technique, the synchronization parameters are first estimated based on a data-aided feed-forward estimation scheme. Then, a phase tracker using decision-directed DPLL estimates the phase offset for the data portion of the burst data. From simulation results, it shows fast synchronization with shorter preamble maintaining reasonable BER performance at low S/N.

Phase Resonance in Centrifugal Fluid Machinery -A Comparison between Pump Mode and Turbine Mode Operations and a Discussion of Mechanisms of Flow Rate Fluctuation through a Stator-

  • Yonezawa, Koichi;Toyahara, Shingo;Motoki, Shingo;Tanaka, Hiroshi;Doerfler, Peter;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.2
    • /
    • pp.42-53
    • /
    • 2014
  • Phase resonance in Francis type hydraulic turbine is studied. The phase resonance is a phenomenon that the pressure fluctuation in the penstock of hydraulic turbine installation can become very large when the pressure waves from each guide vane caused by the interaction with the runner vane reach the penstock with the same phase. Experimental and numerical studies have been carried out using a centrifugal fan. In the present study, comparisons between the pump mode and the turbine mode operations are made. The experimental and numerical results show that the rotational direction of the rotor does not affect characteristics of the pressure fluctuation but the propagation direction of the rotorstator interaction mode plays an important role. Flow rate fluctuations through the stator are examined numerically. It has been found that the blade passing flow rate fluctuation component can be evaluated by the difference of the fluctuating pressure at the inlet and the outlet of the stator. The amplitude of the blade passage component of the pressure fluctuation is greater at the stator inlet than the one at the stator outlet. The rotor-stator interaction mode component is almost identical at the inlet and the outlet of the stator. It was demonstrated that the pressure fluctuation in the volute and connecting pipe normalized by the flow rate fluctuation becomes the same for pump and turbine mode operations, and depends on the rotational direction on the interaction mode.

Dispersion tolerant transmission of the return-to-zero signal with alternate-phase generated from a rational harmonic mode-locked ring laser (유리수차 조화 모드잠김 광섬유 링레이저로부터 발생된 교차 위상 RZ(return-to-zero) 신호의 분산 제어 전송)

  • Jo, Hyun-Jeong;Hwang, Jong-Gyu;Kim, Baek-Hyun;Baek, Jong-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.203-204
    • /
    • 2006
  • We present and demonstrate a novel method of alternate-phase return-to-zero (RZ) signal generation and pulse-amplitude equalization simultaneously in a rational harmonic mode-locked fiber ring laser, using a dual-drive Mach-Zehnder (MZ) modulator. By adjusting the voltages applied to both arms of the modulator, the rational harmonic mode-locked pulse trains are equalized in their amplitudes. In addition to that, the amplitude-equalized pulse trains multiplying the repetition rate at ${\sim}10\;GHz$ have alternate $\pi$ phase difference between adjacent pulses. The alternate-phase RZ signal generated by the proposed method enhances transmission performance through the single-mode fiber (SMF) links without dispersion compensation.

  • PDF