• 제목/요약/키워드: In phase mode

검색결과 2,007건 처리시간 0.038초

계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어 (An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition)

  • 박태현;김학원;조관열;민준기;최원일
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

출력이 직렬 결합된 단상 Quasi Z-소스 AC-AC 컨버터 (A Single-Phase Quasi Z-Source AC-AC Converter with a Series Connection of the Output Terminals)

  • 엄준현;정영국;임영철;최준호
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.415-429
    • /
    • 2011
  • 본 연구에서는 출력이 직렬 연결된 단상 quasi Z-소스 AC-AC 컨버터를 제안하였다. 제안된 시스템은 단상quasi Z-소스 AC-AC 컨버터 2대의 입력 단을 병렬로 연결하고 출력 단을 직렬로 연결한 구조로 되어 있으며, 역상 모드와 동상 모드 별 전류 흐름과 출력전압의 형성 과정을 나타내었다. DSP로 제어되는 실험 시스템을 제작하여 PSIM시뮬레이션 결과와 비교 분석하였다. 그 결과 각 모드별로 듀티 비를 제어하여 원하는 출력 전압을 벅-부스트 할 수 있었다. 컨버터 1대가 단독으로 운전한 경우에 비하여, 각각의 모드에 대하여 부하 저항의 증가에 따른컨버터 효율과 입력 역률을 제안된 방법에 의하여 개선할 수 있었다. 또한 역상 모드의 경우, 일정 부하에서 컨버터의 효율과 입력 역률을 각각 10[%]와 35[%]정도 개선하였으며, 특히 부하 저항이 변동하는 과도상태에서도 일정한 출력 전압을 유지할 수 있었다.

Non-data Aided Timing Phase Recovery Scheme for Digital Equalization of Chromatic Dispersion and Polarization Mode Dispersion

  • Park, Jang-Woo;Chung, Won-Zoo;Park, Jong-Sun;Kim, Sung-Chul
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.367-372
    • /
    • 2009
  • In this paper we propose an electronic domain timing phase selection scheme for the optical communication systems suffering from inter-symbol-interference (ISI) distortion due to chromatic dispersion (CD) or polarization mode dispersion (PMD). In the presence of CD/PMD a proper timing phase selection is important for discrete time domain equalizers, since different timing phases produce different nonlinear ISI channels of different severity. The proposed timing phase recovery scheme based on dispersion minimization (DM) practically approximates the optimal minimum mean squared error (MMSE) timing phase without training signals which reduces overall throughput substantially, especially in time-varying channels such as PMD. The simulation results show that the proposed DM timing agrees with MMSE timing phase, under proper normalization of the received signals, for various dispersion and OSNR.

Phase diagrams adn stable structures of stranski-krastanov structure mode for III-V ternary quantum dots

  • Nakajima, Kazuo;Ujihara, Toru;Miyashita, Satoru;Sazaki, Gen
    • 한국결정성장학회지
    • /
    • 제9권4호
    • /
    • pp.387-395
    • /
    • 1999
  • The strain, surface and interfacial energies of III-V ternary systems were calculated for three kinds of structure modes: the Frank-van der Merwe(FM) mode, the Stanski-Krastanov(SK) mode and the Volmer-Weber(VW) mode. The free energy for each mode was estimated as functions of thickness and composition or lattice misfit. Through comparison of the free energy of each mode, it was found that the thickness-composition phase diagrams of III-V ternary systems can be determined only by considering the balance of the free energy and three kinds of structure modes appear in the phase diagrams. The SK mode appears only when the lattice misfit is large and/or the lattice layer is thick. The most stable structure of the SK mode is a cluster with four lattice layers or minimum thickness on a wetting layer of increasing lattice layers. The VW mode appears when the lattice misfit is large and the lattice layer is thin and only in the INPSb/InP and GaPSb/GaP system which have the largest lattice misfit of III-V ternary systems. The stable region of the SK mode in the GaPSb/GaP and InPSb/InP phase diagrams is largest of all because the composition dependence of the strain energy of these systems is stronger than that of the other systems. The critical number of lattice layers below which two-dimensional(2D) layers precede the three-dimensional(3D) nucleation in the SK mode at x=1.0 depends on the lattice misfit.

  • PDF

천부지각 2차원 속도구조를 위한 레일리파의 군속도와 위상속도 역산의 비교 연구 (A Study of the comparison of Inversion of Rayleigh wave Group and Phase Velocities for Regional Near-Surface 2-Dimensional Velocity Structure)

  • 이보라;정희옥
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.51-59
    • /
    • 2006
  • 서해안 조간대에서 24 channel 탐사기로 획득한 표면파 자료의 위상속도와 군속도를 구한다음, 이를 역산하여 그 결과를 비교하였다. 위상속도의 분산곡선은 tau-p stacking 방법에 의하여, 군속도의 분산곡선은 wavelet analysis와 Multiple Filtering Technique의 두가지 방법을 사용하여 구하였다. 위상속도의 오차가 군속도의 오차보다 더 큰 것을 확인하였다. 군속도의 경우, wavelet analysis가 Multiple Filtering Technique 보다 fundamental mode와 higher mode를 구분하는데 더 효과적이었다. 역산결과, 군속도의 fundamental mode와 1st higher mode 를 동시에 사용했을 때, 공간적 해상도가 가장 좋았다. 이연구는 천부 지반의 S파 속도 구조를 구하는데, 군속도의 higher mode를 포함한 군속도 분산곡선을 사용하는 것이 효과적임을 시사한다.

  • PDF

빠른 응답 특성을 가지는 Average Current Mode Control 설계 기법 연구 (Average Current Mode Control Technique Having Fast Response)

  • 박해찬;김일송
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.231-239
    • /
    • 2017
  • A novel current control technique with fast response and application in an unbalanced system is proposed in this paper. Contrary to the conventional PI and dead-beat current control techniques, the proposed method is adopted to the valley current mode control (VCMC) and average current mode control (ACMC) methods to overcome the phase delay caused by conventional methods. The advantages of the proposed system are simplicity of structure and ease of implementation. The VCMC and ACMC methods are established and applied to the buck converter, boost converter, three-phase PWM converter, and three-phase inverter. The control performances of the proposed systems are shown by computer simulations and verified by experimental results.

유체로 연성된 두 직사각 평판의 고유진동에 관한 해석적 연구 (Analytical Study on the Free Vibration of Two Rectangular Plates Coupled with Fluid)

  • 유계형;정경훈;이성철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.647-651
    • /
    • 2002
  • This study dealt with the free vibration of two identical rectangular plates coupled with fluid. In order to investigate the vibration characteristics of fluid-coupled rectangular plates, an analytical method based on the finite Fourier series expansion and Rayleigh-Ritz method was suggested. A commercial computer code, ANSYS was used to perform finite element analysis and we investigated the vibration characteristics with mode shapes and natural frequencies. As a result, the transverse vibration modes, in-phase and out-of-phase, were observed alternately in the fluid-coupled system. The effect of fluid bounding and plate boundary condition on the fluid-coupled natural frequency were investigated. It was shown that the mode numbers increased, the normalized natural frequencies monotonically increased.

  • PDF

동기식 버스트 통신시스템 적용을 위한 새로운 반송파 동기 기법에 관한 연구 (A Study on a New Carrier Recovery Algorithm for Coherent Burst-mode Communication Systems)

  • 박성복
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1043-1048
    • /
    • 2011
  • In this paper, a newsynchronization technique applied to burst-mode communication is proposed. A synchronization technique is to estimate carrier frequency and phase offsets in a noisy channel environment. A fundamental problem for estimating the parameters(carrier phase and frequency offsets) in burst-mode transmission is that the ways of pursuing estimation accuracy and transmission efficiency are always trade-off. To solve this problem, a new carrier recovery technique is proposed to improve the transmission efficiency with reliable performance especially at low S/N. In the proposed technique, the synchronization parameters are first estimated based on a data-aided feed-forward estimation scheme. Then, a phase tracker using decision-directed DPLL estimates the phase offset for the data portion of the burst data. From simulation results, it shows fast synchronization with shorter preamble maintaining reasonable BER performance at low S/N.

Phase Resonance in Centrifugal Fluid Machinery -A Comparison between Pump Mode and Turbine Mode Operations and a Discussion of Mechanisms of Flow Rate Fluctuation through a Stator-

  • Yonezawa, Koichi;Toyahara, Shingo;Motoki, Shingo;Tanaka, Hiroshi;Doerfler, Peter;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권2호
    • /
    • pp.42-53
    • /
    • 2014
  • Phase resonance in Francis type hydraulic turbine is studied. The phase resonance is a phenomenon that the pressure fluctuation in the penstock of hydraulic turbine installation can become very large when the pressure waves from each guide vane caused by the interaction with the runner vane reach the penstock with the same phase. Experimental and numerical studies have been carried out using a centrifugal fan. In the present study, comparisons between the pump mode and the turbine mode operations are made. The experimental and numerical results show that the rotational direction of the rotor does not affect characteristics of the pressure fluctuation but the propagation direction of the rotorstator interaction mode plays an important role. Flow rate fluctuations through the stator are examined numerically. It has been found that the blade passing flow rate fluctuation component can be evaluated by the difference of the fluctuating pressure at the inlet and the outlet of the stator. The amplitude of the blade passage component of the pressure fluctuation is greater at the stator inlet than the one at the stator outlet. The rotor-stator interaction mode component is almost identical at the inlet and the outlet of the stator. It was demonstrated that the pressure fluctuation in the volute and connecting pipe normalized by the flow rate fluctuation becomes the same for pump and turbine mode operations, and depends on the rotational direction on the interaction mode.

유리수차 조화 모드잠김 광섬유 링레이저로부터 발생된 교차 위상 RZ(return-to-zero) 신호의 분산 제어 전송 (Dispersion tolerant transmission of the return-to-zero signal with alternate-phase generated from a rational harmonic mode-locked ring laser)

  • 조현정;황종규;김백현;백종현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.203-204
    • /
    • 2006
  • We present and demonstrate a novel method of alternate-phase return-to-zero (RZ) signal generation and pulse-amplitude equalization simultaneously in a rational harmonic mode-locked fiber ring laser, using a dual-drive Mach-Zehnder (MZ) modulator. By adjusting the voltages applied to both arms of the modulator, the rational harmonic mode-locked pulse trains are equalized in their amplitudes. In addition to that, the amplitude-equalized pulse trains multiplying the repetition rate at ${\sim}10\;GHz$ have alternate $\pi$ phase difference between adjacent pulses. The alternate-phase RZ signal generated by the proposed method enhances transmission performance through the single-mode fiber (SMF) links without dispersion compensation.

  • PDF