• 제목/요약/키워드: Impulse voltages

검색결과 100건 처리시간 0.037초

불평등전계중에서 진동성 임펄스전압에 대한 $SF_6$가스의 절연특성 (Dielectric Characteristics of $SF_6$ gas Stressed by the Oscillating Impulse Voltage in the Non-uniform Electric Fields)

  • 이복희;길경석;황교정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.284-286
    • /
    • 1994
  • This paper describes the dielectric characteristics of $SF_6$ gas in non-uniform electric filed under lightning under lightning impulse and oscillating impulse voltages. The breakdown voltage-time characteristics and the breakdown voltage-pressure characteristics are measured over a pressure range extending from 0.1 to 0.5 [MPa] fur the coaxial electrode with a needle protrusion. The curvature radius of needle protrusion is 0.3[mm]. Also, the growth of the predischarge is simultaneously observed. As a result the polarity effect is pronounced, and the breakdowns voltage under the oscillating impulse voltage are higher than those under the lightning impulse voltage. It is found that the breakdown mechanism md predischarge phenomena ate closely related with the polarity and waveforms of the testing voltage.

  • PDF

한양대학교 1600kV/70kA 충격 전압/전류 시험설비 구축 (HY 1600kV/70kA Impulse Voltage/Current Test Facility)

  • 장용무;김철호;황률;이방욱;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.229-229
    • /
    • 2009
  • This Impulse Voltage and Current Test System is designed for performing of impulse voltage tests with Lightning impulse voltage 1.2/50(LI) up to 1520kV peak value and switching impulse voltages 250/2500(SI) up to 1120kV peak valu acc. to IEC 60060-1, and furthermore for impulse current test, e.g. testing of arrester sections($U_{res}$=95kV)with current impulses 4/10 and 8/20 up to 70kA peak value.

  • PDF

토양종류에 따른 임펄스전압에 의한 이온화 현상 (Ionization Phenomena caused by Impulse Voltages in various soils)

  • 박건훈;김회구;김정철;김기복;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1301-1302
    • /
    • 2008
  • The resistivity of soils around ground electrodes is changed considerably according to the factors such as soil types, water contents, grain size, temperature and pressure. In this study, ionization characteristics of different soil types containing the same amount of water content due to the impulse voltages are investigated. In order to analyze soil ionization phenomena, critical electric field intensity for ionization and pre-ionization and post-ionization resistances are measured and discussed.

  • PDF

임펄스전압에 의한 반구형 전극계에서 토양의 이온화 현상 (Soil Ionization Phenomena around a Hemispherical Electrode Stressed by Impulse Voltages)

  • 허대민;김회구;이복희
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.601-608
    • /
    • 2016
  • 접지전극이 매설되는 토양의 전기적 특성은 지역, 계절, 환경적 요인에 따라 저항률이 다양하게 변화한다. 접지전극 주변에서의 전기적 방전현상은 매우 다르게 발생하고, 이는 접지의 성능에 큰 영향을 미친다. 접지시스템의 설계 시에 다양한 조건에서 토양의 방전 특성과 이온화 현상에 관한 분석이 필요하다. 본 연구의 목적은 토양의 이온화 현상과 과도접지임피던스의 상관관계를 파악하는데 있다. 본 논문에서는 뇌임펄스전압에 의해 접지극 주변에서 발생하는 토양의 이온화 작용과 관련된 파라미터와 과도적인 접지저항에 관한 실험적 연구결과를 기술하였다.

Analysis of Soil Ionization Behaviors under Impulse Currents

  • Lee, Bok-Hee;Park, Geon-Hun;Kim, Hoe-Gu;Lee, Kyu-Sun
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.98-105
    • /
    • 2009
  • This paper presents the characteristics of soil ionization for different water contents, and the parameters associated with the dynamic properties of a simple model grounding system subject to lightning impulse currents. The laboratory experiments for this study were carried out based on factors affecting the soil resistivities. The soil resistivities are adjusted with water contents in the range from 2 to 8% by weight. A test cell with a spherical electrode buried in the middle of the hemispherical container was used. As a result, the electric field intensity $E_c$ initiating ionization is decreased with the reduction of soil resistivities. Also, as the water content increased, the pre-ionization resistance $R_1$ and the post-ionization resistance $R_2$ became lower with increasing current amplitude. The time-lag to ionization $t_1$ and the time-lag to the second current peak $t_2$ at high applied voltages were significantly shorter than those of low applied voltages. It was found that the soil ionization behaviors are highly dependent on the water content and the applied voltage amplitude.

Underwater Discharge Phenomena in Inhomogeneous Electric Fields Caused by Impulse Voltages

  • Lee, Bok-Hee;Kim, Dong-Seong;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.329-336
    • /
    • 2010
  • The paper describes the electrical and optical properties of underwater discharges in highly inhomogeneous electric fields caused by 1.2/50 ${\mu}s$ impulse voltages as functions of the polarity and amplitude of the applied voltage, and various water conductivities. The electric fields are formed by a point-to-plane electrode system. The formation of air bubbles is associated with a thermal process of the water located at the tip of the needle electrode, and streamer coronas can be initiated in the air bubbles and propagated through the test gap with stepped leaders. The fastest streamer channel experiences the final jump across the test gap. The negative streamer channels not only have more branches but are also more widely spread out than the positive streamer channels. The propagation velocity of the positive streamer is much faster than that of the negative one and, in fact, both these velocities are independent of the water conductivity; in addition the time-lag to breakdown is insensitive to water conductivity. The higher the water conductivity the larger the pre-breakdown energy, therefore, the ionic currents do not contribute to the initiation and propagation of the underwater discharges in the test conditions considered.

뇌임펄스전압에 대한 SF6와 dry-air의 절연특성 (Dielectric Characteristics of SF6 and Dry-Air Gases under Lightning Impulse Voltage)

  • 이봉;유양우;김동규;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.142-149
    • /
    • 2010
  • 본 논문은 준평등전계에서 뇌임펄스전압에 대한 $SF_6$와 dry-air의 절연파괴 특성에 대하여 기술하였다. 준평등전계로 사용된 구-평판전극계의 전계이용률은 71[%]이다. $SF_6$는 0.1~0.2[MPa] 범위에서, dry-air는 0.2~0.6[MPa]에서 $SF_6$와 dry-air의 절연파괴전압을 임펄스전압의 극성과 가스압력에 따라 측정 분석하였다. 그 결과 뇌임펄스전압에 대한 두 가스의 절연파괴전압은 정극성이 부극성보다 높았으며, $SF_6$의 절연파괴전압이 dry-air의 절연파괴전압보다 약 2.67배정도 높았다. 본 연구결과는 뇌서지에 대하여 우수한 성능을 가지는 배전기기에서 $SF_6$의 대체가스 성능 평가에 유용한 정보가 될 것이다.

과도고전압측정에서 측정값 보정에 관한 연구 (RECONSTRUCTION OF HV IMPLUSES DEFORMED BY THE MEASURING SYSTEM)

  • 백용현;이국중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.153-156
    • /
    • 1990
  • High voltage impulse measuring system gives an output signal that is a deformed responce of the input signal. This paper describes a method of reconstructing the input signal from the deformed output. The method is applicable to any wave shape, full or chopped impulse voltages.

  • PDF

가스절연개폐장치에 있어서 금속입자 존재시 임펄스전압에 대한 $SF_6$가스의 절연특성 (Dielectric Characteristics of Gaseous $SF_6$ for Impulse Voltages in Presence of a Metallic Particle in GIS)

  • 이복희;이경옥;이창준
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.22-29
    • /
    • 2000
  • 본 논문은 가스절연개폐장치내에 바늘모양의 금속입자가 존재하는 경우 $\pm1.2/44[{\mu}s]$ 비진동성 임펄스와 $\pm0.4[{\mu}s]/1.14[MHz]$ 진동성 임펄스전압이 인가되었을 때 $SF_6$가스의 절연특성에 관한 것으로 절연파괴전압-시간 특성 (V-t 특성) 및 절연파괴전압-압력 특성(V-p 특성)을 측정하고 검토하였다. 실험은 길이 10[mml, 반경 0.5[mm]인 바늘모양의 돌기물에 의해 형성된 불평등 전계이며, 가스압력이 0.1~0.5[MPa]인 범위에서 수행하였다. 그 결과 절연 파괴는 정.부극성 모두 계단상 펄스에 의해 진전하는 리더메커니즘으로 발생하였다. 정극성의 진동성 임펼스전압이 인가되었을 때 절연파괴전압이 가장 낮았으며, 짧은 시간범위에서 V-t곡선의 감쇠가 현저하고 가스압력의 의존성이 적게 나타났다. 이에 반해 부극성의 경우 V-t 특성과 V-p 특성은 인가전압의 파형에 대한 의존성이 현저하였다.

  • PDF

산화아연 피뢰기 소자의 다중 뇌 임펄스 특성 (Effect of Multiple Lightning Impulse Currents on Zinc Oxide Arrester Blocks)

  • 이복희;강성만;박건영;최휘성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.22-24
    • /
    • 2003
  • In this work, in order to investigate the effect of multiple lightning impulse currents on zinc oxide arrester blocks. We have been designed and fabricated a multi-impulse generator which can produce quintuple voltages with $1.2/50{\mu}s$ to 100kV and quintuple currents with $8/20{\mu}s$ to 12kA and we have evaluated the characteristics of zinc oxide arrester block using several electrical and physical methods after the multi-impulse test. It was found that the multi-impulse failures of ZnO arrester blocks were mainly caused by surface flashover and the multi-impulse currents test would be more suitable than single impulse current test in evaluation of the characteristics of zinc oxide arrester blocks corresponding to actual situations.

  • PDF